球囊辅助结肠镜不增加腺瘤漏诊率:单中心串联随机临床试验结果
A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial.
A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial.
结直肠癌是全球第三大癌症死亡原因。结肠镜检查可以预防这一并发症,但由于腺瘤漏诊而并不完美。一种涉及可变硬度球囊的装置已被开发出来:G-EYE结肠镜检查(GEYEC)。目前关于GEYEC的前瞻性研究仅有少数。我们在筛查性结肠镜检查中将GEYEC与标准结肠镜检查(SC)进行了比较。我们开展了一项单中心背靠背结肠镜检查串联随机临床试验。年龄大于50岁的患者被转诊接受筛查性结肠镜检查,其中三分之一粪便免疫化学检测阳性的患者被纳入。A组患者先接受SC再接受GEYEC;B组则顺序相反。主要目的是评估和比较两组之间的腺瘤漏诊率(AMR)。次要目的是比较进展期腺瘤漏诊率(aAMR)、每种结肠镜的不良事件以及GEYEC的退镜稳定性率。2020年1月至2023年6月期间共纳入195例患者。共有164例患者(83例女性,占51%)完成了两次检查,由六名经验丰富的操作者实施。A组的平均AMR为0.438,B组为0.393(P=0.713)。A组的平均aAMR为0.176,B组为0.036(P=0.76)。显著不良事件(≥AGREE II)的发生率为1.8%,均未归因于GEYEC球囊。在79%的病例中,操作者认为GEYEC在退镜过程中提供了更好的稳定性。尽管GEYEC可靠且安全,但与SC相比,GEYEC并未降低AMR或aAMR。然而,它提高了筛查过程中退镜的舒适度。
Colorectal cancer is the third leading cause of cancer death worldwide. Colonoscopy can prevent this complication but is imperfect because of missed adenoma. A device involving a variable-rigidity balloon has been developed: G-EYE colonoscopy (GEYEC). Only a few prospective studies on GEYEC are available. We compared GEYEC to standard colonoscopy (SC) during screening colonoscopy. We performed a single-center back-to-back colonoscopy tandem randomized clinical trial. Patients older than 50 years were referred for screening colonoscopy, among whom one-third with a positive fecal immunochemical test were included. In Arm A, patients underwent SC followed by GEYEC; in Arm B, the opposite occurred. The primary objective was to assess and compare adenoma miss rate (AMR) between arms. The secondary objectives were to compare advanced AMRs (aAMRs), adverse events for each colonoscope and withdrawal stability rates for GEYEC. One hundred ninety-five patients were included between January 2020 and June 2023. A total of 164 patients (83 women, 51%) completed the two procedures, performed by six experienced operators. The mean AMRs were 0.438 in Arm A and 0.393 in Arm B ( = 0.713). The mean aAMRs were 0.176 in Arm A and 0.036 in Arm B ( = 0.76). The rate of significant adverse events (≥AGREE II) was 1.8%, and none were attributed to the GEYEC balloon. In 79% of cases, operators felt that GEYEC provided more stability during withdrawal. Although it is reliable and safe, compared with SC, GEYEC does not reduce AMR or aAMR. However, it increases the comfort of scope withdrawal during screening.
Jean-Philippe Ratone, Yanis Dahel, Cristophe Zemmour, Solène Hoibian, Christian Pesenti, Florat Poizat, et al. A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial.. Endoscopy international open. 2026; doi:10.1055/a-2901-5859.
Jean-Philippe Ratone, Yanis Dahel, Cristophe Zemmour, Solène Hoibian, Christian Pesenti, Florat Poizat, et al (2026). A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial.. Endoscopy international open. https://doi.org/10.1055/a-2901-5859
Jean-Philippe Ratone, Yanis Dahel, Cristophe Zemmour, Solène Hoibian, Christian Pesenti, Florat Poizat, et al. A Balloon-assisted Colonoscope does not Increase the Adenoma Miss Rate: Outcomes of a Single-center Tandem Randomized Clinical Trial.[J]. Endoscopy international open, 2026 doi:10.1055/a-2901-5859.