假体存活与自体脂肪隆胸在破裂管理中的应用
Implant Survival and Autologous Breast Augmentation in Rupture Management.
Implant Survival and Autologous Breast Augmentation in Rupture Management.
硅胶乳房假体仍然是美容外科的主要手段;然而,远期破裂仍是一项重要并发症。MRI对检测无症状破裂具有更高的敏感性。对于拒绝再次植入假体的患者,采用带蒂横行腹直肌肌皮瓣(TRAM)联合脂肪移植的自体乳房增大术提供了一种自然、持久的替代方案。本研究旨在评估因破裂行假体取出术后,采用带蒂TRAM皮瓣联合脂肪移植的混合自体乳房增大术的远期假体存活率及结局。对150例女性患者共179枚破裂假体(2022年6月至2024年9月)进行了回顾性分析。假体破裂经3T MRI确认。采用Kaplan-Meier生存分析评估假体使用年限。其中41例患者亚组接受了改良带蒂TRAM皮瓣联合脂肪移植的自体乳房重建。术中皮瓣体积采用截锥体几何模型计算。术后6至12个月通过MRI量化脂肪保留率。患者自报满意度采用BREAST-Q术后增大模块进行评估。MRI显示了linguine征(25.1%)、泪滴征(15.6%)及混合破裂征象。Kaplan-Meier分析显示20年假体存活率为83%。在自体组(=41)中,术中平均体积为328.5 cc,随访MRI显示脂肪保留率为83.0%。BREAST-Q平均满意度评分为62.7,与体积保留呈正相关(=0.317,=.043)。采用TRAM皮瓣联合脂肪移植的混合自体乳房增大术是再次植入假体的一种可靠且美学效果满意的替代方案。MRI有助于准确诊断破裂及术后体积监测。该技术还可带来腹部轮廓改善的益处并降低远期费用,使其成为特定患者的理想选择。证据等级4(治疗性)
Silicone breast implants remain a mainstay of aesthetic surgery; however, long-term rupture remains a significant complication. MRI offers superior sensitivity for detecting silent ruptures. In patients declining reimplantation, autologous breast augmentation using a pedicled transverse rectus abdominis myocutaneous (TRAM) flap combined with fat grafting presents a natural, durable alternative. The purpose of this study was to evaluate long-term implant survival and the outcomes of hybrid autologous augmentation using pedicled TRAM flap and fat grafting following explantation for rupture. A retrospective review was conducted on 150 female patients with 179 ruptured implants (June 2022-September 2024). Implant rupture was confirmed through 3T MRI. Implant longevity was analyzed using Kaplan-Meier survival. A subgroup of 41 patients underwent autologous reconstruction using a modified pedicled TRAM flap plus fat grafting. Intraoperative flap volume was calculated using a geometric model for truncated pyramids. Fat retention was quantified through MRI at 6 to 12 months. Patient-reported satisfaction was assessed using the BREAST-Q Postoperative Augmentation Module. MRI demonstrated linguine (25.1%), teardrop (15.6%), and combined rupture signs. Kaplan-Meier analysis showed a 20-year implant survival rate of 83%. In the autologous group ( = 41), the average intraoperative volume was 328.5 cc, with 83.0% fat retention on follow-up MRI. The mean BREAST-Q satisfaction score was 62.7, positively correlating with volume retention ( = 0.317, = .043). Hybrid autologous breast augmentation using a TRAM flap and fat grafting is a reliable and aesthetically satisfying alternative to reimplantation. MRI facilitates accurate rupture diagnosis and postoperative volumetric monitoring. This technique also yields abdominal contouring benefits and reduced long-term costs, making it an attractive option for selected patients. Level of Evidence 4 Therapeutic
Tung Dinh Nguyen. Implant Survival and Autologous Breast Augmentation in Rupture Management.. Aesthetic surgery journal. Open forum. 2026; doi:10.1093/asjof/ojag077.
Tung Dinh Nguyen (2026). Implant Survival and Autologous Breast Augmentation in Rupture Management.. Aesthetic surgery journal. Open forum. https://doi.org/10.1093/asjof/ojag077
Tung Dinh Nguyen. Implant Survival and Autologous Breast Augmentation in Rupture Management.[J]. Aesthetic surgery journal. Open forum, 2026 doi:10.1093/asjof/ojag077.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出