使用双着丝粒分析和贝叶斯框架对介入放射科医生慢性辐射暴露的生物学剂量测定
Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.
Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.
长期暴露于诱变因素人群的细胞遗传学研究因诸多方法学限制而具有挑战性。本研究旨在证明双着丝粒体分析结合高级数据解读在长期受照医务人员辐射生物剂量学中的适用性。研究测量了12名具有5-42年职业暴露史介入放射科医师及14名未暴露对照者培养外周血淋巴细胞中的双着丝粒体频率。数据处理方法包括对观察到的畸变率进行数学“展开”、从体外低剂量双着丝粒体校准曲线推导稳健的线性剂量-反应系数,以及采用贝叶斯型统计框架计算“真实”畸变率及相应剂量估计的后验概率密度。放射科医师的平均双着丝粒体频率显著高于对照水平,但个体畸变率与工龄无相关性(r=0.268)。经“展开”处理后,呈现强正相关(r=0.843)。“展开”后的双着丝粒体率转换为累积剂量估计值49-595 mGy。“真实”畸变率的贝叶斯后验概率密度对应最可能年剂量为3.7-27.9 mGy。年剂量“较非真实值更可能为真”的置信区间为0.8至39.3 mGy,12例中有11例的置信区间上限超过20 mGy。所提出的方法显著提高了慢性照射细胞遗传学生物剂量学的准确性和解释力。所得剂量估计值可用于评估辐射相关健康风险,并为职业受照个体的个体辐射防护措施提供支持。
Cytogenetic studies in populations chronically exposed to mutagens are challenging due to a number of methodological constraints. The aim of the study was to demonstrate the applicability of dicentric assay, combined with advanced data interpretation, for radiation biodosimetry in chronically exposed medical staff. Dicentric frequencies were measured in cultured blood lymphocytes from 12 interventional radiologists with 5-42 years of professional exposure and 14 unexposed controls. The data processing methodology included a mathematical "unfolding" of observed aberration yields, a robust linear dose-response coefficient derived from in vitro low-dose calibration curve for dicentrics, and a Bayesian-type statistical framework for calculating posterior probability densities for "true" aberration yields and corresponding dose estimates. The mean dicentric frequency in radiologists significantly exceeded the control level, but individual yields showed no dependence on the years of service (r = 0.268). After "unfolding", a strong positive correlation emerged (r = 0.843). "Unfolded" dicentric yields were converted into cumulative dose estimates of 49 - 595 mGy. Bayesian posterior probability densities of "true" aberration yields corresponded to the most probable annual doses of 3.7 - 27.9 mGy. Confidence intervals of annual doses, which are "more probable to be true than non-true", ranged from 0.8 to 39.3 mGy, and their upper limits exceeded 20 mGy in eleven cases out of twelve. The proposed approach substantially enhances the accuracy and interpretative power of cytogenetic biodosimetry of chronic irradiation. The resulting dose estimates can be used for assessment of radiation-associated health risks and support individual radiation protection measures for occupationally exposed individuals.
Volodymyr Vinnikov, Dominika Kochanová, Pavol Košík, Sachin Gulati, Katarína Vigašová, Matúš Durdík, et al. Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.. Mutation research. Genetic toxicology and environmental mutagenesis. 2026; doi:10.1016/j.mrgentox.2026.503947.
Volodymyr Vinnikov, Dominika Kochanová, Pavol Košík, Sachin Gulati, Katarína Vigašová, Matúš Durdík, et al (2026). Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.. Mutation research. Genetic toxicology and environmental mutagenesis. https://doi.org/10.1016/j.mrgentox.2026.503947
Volodymyr Vinnikov, Dominika Kochanová, Pavol Košík, Sachin Gulati, Katarína Vigašová, Matúš Durdík, et al. Biological dosimetry of chronic radiation exposure in interventional radiologists using dicentric assay and a Bayesian framework.[J]. Mutation research. Genetic toxicology and environmental mutagenesis, 2026 doi:10.1016/j.mrgentox.2026.503947.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出