不同计算机辅助检测产品在结肠镜检查中的比较疗效:随机对照试验的网络荟萃分析

Comparative Efficacy Of Different Computer-Aided Detection Products in Colonoscopy: A Network Meta-Analysis Of Randomized Controlled Trials.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

多种计算机辅助检测(CADe)系统已被开发用于提高结肠镜检查中的腺瘤检出率,但其比较疗效和效果一致性仍不确定。本网络荟萃分析旨在比较不同CADe系统在多项检出结局中的疗效。系统检索了MEDLINE、Embase、Scopus和Cochrane Library中比较CADe辅助结肠镜检查与无CADe结肠镜检查或其他CADe系统的随机对照试验(RCT)。主要结局为腺瘤检出率(ADR)。次要结局为每次结肠镜检查腺瘤数(APC)和腺瘤漏诊率(AMR)。采用随机效应网络荟萃分析综合直接和间接证据。共纳入41项RCT(31,789例患者;14种CADe系统)。在探索性完整网络分析中,14种系统中有10种显著改善ADR(RR范围1.12-1.76),9种增加APC,3种降低AMR。在FDA获批系统分析中,6种系统中有3种改善ADR(RR范围1.14-1.25),而3种未改善。在符合ESGE(≥25%)和ASGE/ACG(≥35%)推荐对照组ADR阈值的研究中,若干系统仍保持显著获益,但不同平台的效果存在差异,且在较高基线ADR下的衰减并不一致。荟萃回归显示基线ADR与治疗效果无关。CADe辅助结肠镜检查的有效性在不同平台间并不一致,并因具体产品而异。这些发现支持对CADe技术进行系统特异性而非类别性评估。然而,鉴于若干结局的证据确定性较低,且网络内缺乏头对头比较和闭环设计,比较性估计值应谨慎解读。

Abstract

Multiple computer-aided detection (CADe) systems have been developed to improve adenoma detection during colonoscopy, but their comparative efficacy and consistency of effect remain uncertain. This network meta-analysis aimed to compare the efficacy of different CADe systems across multiple detection outcomes. MEDLINE, Embase, Scopus, and the Cochrane Library were systematically searched for randomized controlled trials (RCTs) comparing CADe-assisted colonoscopy versus colonoscopy without CADe or other CADe systems. The primary outcome was adenoma detection rate (ADR). Secondary outcomes were adenomas per colonoscopy (APC) and adenoma miss rate (AMR). A random-effects network meta-analysis was performed to synthesize direct and indirect evidence. Forty-one RCTs (31,789 patients; 14 CADe systems) were included. In the exploratory complete-network analysis, 10 of 14 systems significantly improved ADR (RR range 1.12-1.76), 9 increased APC, and 3 reduced AMR. In the FDA-cleared systems analysis, 3 of 6 improved ADR (RR range 1.14-1.25), whereas 3 did not. Several systems retained a significant benefit in studies meeting the control-arm ADR thresholds recommended by ESGE (≥25%) and ASGE/ACG (≥35%), although effects varied across platforms and attenuation at higher baseline ADR was not uniform. Baseline ADR was not associated with treatment effects in meta-regression. The effectiveness of CADe-assisted colonoscopy is not uniform across platforms and varies according to the specific product. These findings support a system-specific rather than class-based evaluation of CADe technologies. However, comparative estimates should be interpreted cautiously given the low certainty of evidence for several outcomes and the absence of head-to-head comparisons and closed loops within the network.

如何引用

AMA

Marcello Maida, Giulio Calabrese, Louis H S Lau, Zhouyao Qian, Alessandro Vitello, Giovanni Marasco, et al. Comparative Efficacy Of Different Computer-Aided Detection Products in Colonoscopy: A Network Meta-Analysis Of Randomized Controlled Trials.. Endoscopy. 2026; doi:10.1055/a-2936-2838.

APA

Marcello Maida, Giulio Calabrese, Louis H S Lau, Zhouyao Qian, Alessandro Vitello, Giovanni Marasco, et al (2026). Comparative Efficacy Of Different Computer-Aided Detection Products in Colonoscopy: A Network Meta-Analysis Of Randomized Controlled Trials.. Endoscopy. https://doi.org/10.1055/a-2936-2838

GB/T 7714

Marcello Maida, Giulio Calabrese, Louis H S Lau, Zhouyao Qian, Alessandro Vitello, Giovanni Marasco, et al. Comparative Efficacy Of Different Computer-Aided Detection Products in Colonoscopy: A Network Meta-Analysis Of Randomized Controlled Trials.[J]. Endoscopy, 2026 doi:10.1055/a-2936-2838.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Endoscopy 的其他文献