使用磁共振弹性成像对高危MASH的简化定义和基于影像的分层
Simplified definition and imaging-based stratification of at-risk MASH using magnetic resonance elastography.
Simplified definition and imaging-based stratification of at-risk MASH using magnetic resonance elastography.
准确识别存在疾病进展风险的代谢功能障碍相关脂肪性肝炎(MASH)患者(即高危MASH)对于指导resmetirom和司美格鲁肽治疗至关重要。高危MASH定义的不一致使临床风险分层及研究间比较变得复杂。本研究旨在标准化高危MASH的定义,并提出优化的基于磁共振弹性成像的肝脏硬度(LS-MRE)截断值,以改善无创风险分层并更好地指导药物治疗。在这项前瞻性研究中,来自两个医疗中心的413例疑似或确诊代谢功能障碍相关脂肪性肝病(MASLD)患者接受了肝活检和MRE检查。简化的高危MASH定义(MASH伴纤维化分期≥2)所识别出的需要临床关注的患者群体比更严格的定义(要求NAFLD活动度评分≥4且脂肪变、炎症和气球样变各≥1分)更广泛(n=122 vs. 77)。与FIB-4及单项实验室指标(AST、ALT和血小板计数)相比,LS-MRE单独应用在采用简化定义识别高危MASH(AUC 0.91 [0.87, 0.95])和肝硬化(AUC 0.93 [0.88, 0.99])方面显示出最高的诊断准确性(所有比较p<0.01,配对DeLong检验)。与AASLD指南推荐的截断值(3.1-4.4 kPa)相比,优化的LS-MRE截断值(2.8-6.4 kPa)额外识别出25例经活检证实的药物治疗候选者(占所有符合条件的28%),提高了敏感性(80% vs. 50%),同时特异性可接受(73% vs. 88%)。简化的高危MASH定义能够更广泛地识别治疗候选者。LS-MRE显示出优异的诊断性能,并与优化截断值联合应用时可改善无创风险分层。这些发现支持使用MRE指导resmetirom和司美格鲁肽的适用性判断,并改善新兴疗法的可及性。
Accurate identification of patients with metabolic dysfunction-associated steatohepatitis (MASH) at risk of disease progression (at-risk MASH) is critical for guiding resmetirom and semaglutide therapy. Inconsistent definitions of at-risk MASH complicate clinical risk classification and comparisons across studies. This study aimed to standardize the definition of at-risk MASH and propose optimized MRE-based liver stiffness (LS-MRE) cutoffs to improve noninvasive risk stratification and better guide pharmacotherapy. In this prospective study, 413 patients with suspected or diagnosed MASLD from two medical centers underwent liver biopsy and MRE. A simplified definition of at-risk MASH (MASH with fibrosis stage≥2) identified a broader group of patients requiring clinical attention than a stricter definition requiring NAFLD Activity Score≥4 with ≥1 point in steatosis, inflammation, and ballooning (n=122 vs. 77). LS-MRE alone showed the highest diagnostic accuracy for identifying at-risk MASH using the simplified definition (AUC 0.91 [0.87, 0.95]) and cirrhosis (AUC 0.93 [0.88, 0.99]), compared with FIB-4 and individual laboratory parameters (AST, ALT, and platelet count) (p<0.01 for all, paired DeLong tests). Optimized LS-MRE cutoffs (2.8-6.4 kPa) captured 25 additional biopsy-proven pharmacotherapy candidates (28% of all eligible patients) compared to AASLD guidelines-recommended cutoffs (3.1-4.4 kPa), improving sensitivity (80% vs. 50%) with acceptable specificity (73% vs. 88%). A simplified definition of at-risk MASH enables broader identification of treatment candidates. LS-MRE demonstrates excellent diagnostic performance and improves noninvasive risk stratification when paired with optimized cutoffs. These findings support the use of MRE to guide resmetirom and semaglutide eligibility and improve access to emerging therapies.
Jiahui Li, Hao Wu, Kevin J Glaser, Fang-Shu Ou, Armando Manduca, Sudhakar K Venkatesh, et al. Simplified definition and imaging-based stratification of at-risk MASH using magnetic resonance elastography.. Hepatology communications. 2026; doi:10.1097/HC9.0000000000001024.
Jiahui Li, Hao Wu, Kevin J Glaser, Fang-Shu Ou, Armando Manduca, Sudhakar K Venkatesh, et al (2026). Simplified definition and imaging-based stratification of at-risk MASH using magnetic resonance elastography.. Hepatology communications. https://doi.org/10.1097/HC9.0000000000001024
Jiahui Li, Hao Wu, Kevin J Glaser, Fang-Shu Ou, Armando Manduca, Sudhakar K Venkatesh, et al. Simplified definition and imaging-based stratification of at-risk MASH using magnetic resonance elastography.[J]. Hepatology communications, 2026 doi:10.1097/HC9.0000000000001024.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出