基于人工智能的高度近视人工晶状体植入术后穹窿预测工具的回顾性验证

Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

我们的研究评估了一组既往接受EVO可植入胶原透镜(ICL)植入术的患者队列,以回顾性评估ICLGuru™人工智能(AI)尺寸选择工具在预测术后拱高方面的表现。此外,还识别了与拱高预测误差相关的生物测量因素。这项回顾性单中心研究纳入了2023年5月至2025年6月期间接受EVO V4c或V5 ICL植入术的56例患者的104只眼。对已完成ICL手术患者的术前超声生物显微镜(UBM)图像进行回顾性分析,使用ICLGuru生成预测术后拱高。实际术后拱高于1个月、3个月或6个月随访时测量,优先纳入3个月测量值进行分析。采用混合效应回归模型评估生物测量变量与拱高预测误差之间的关联。平均绝对误差为135 ± 110 µm,表明ICLGuru倾向于高估术后拱高(p < 0.001)。在16只实际术后拱高过高的眼中,ICLGuru回顾性识别出15例预测更小尺寸透镜可达到目标拱高的病例,提示这些结果可能已被标记。在7只实际拱高过低的眼中,仅2例可能被ICLGuru标记,表明该工具在预防拱高过低方面作用有限。混合效应回归显示,更大的虹膜角膜角和更高的aRISE与更低的拱高预测误差显著相关(p < 0.05)。ICLGuru在术后拱高预测方面表现出实用价值,其性能与现有机器学习和基于UBM的列线图相当,但在我们的队列中似乎高估了长期拱高。该工具可能有助于识别存在拱高过高风险的眼。aRISE和虹膜角膜角是拱高预测误差的显著预测因素,支持其在未来ICL尺寸选择模型中的重要性。

Abstract

Our study evaluated a cohort of patients who previously underwent EVO Implantable Collamer Lens (ICL) implantation to assess the retrospective performance of the ICLGuru™ artificial intelligence (AI) sizing tool in predicting postoperative vault. Additionally, biometric factors associated with vault prediction error were identified. This retrospective single-center study included 104 eyes from 56 patients who underwent EVO V4c or V5 ICL implantation between May 2023 and June 2025. Preoperative ultrasound biomicroscopy (UBM) images, from patients who had already undergone ICL surgery, were retrospectively analyzed using ICLGuru to generate predicted postoperative vaults. Actual postoperative vault was measured at 1-, 3-, or 6-month follow-up visits, with 3-month measurements preferentially included for analysis. Mixed-effects regression models were used to evaluate associations between biometric variables and vault prediction error. Mean absolute error was 135 ± 110 µm, indicating a tendency for ICLGuru to overestimate postoperative vault ( < 0.001). Among 16 eyes with actual postoperative overvault, ICLGuru retrospectively identified 15 cases in which a smaller lens size was predicted to achieve target vault, suggesting these outcomes may have been flagged. Out of 7 eyes with actual undervault, only two cases may have been flagged with use of ICLGuru, indicating that the tool is not as useful in preventing undervault. Mixed-effects regression demonstrated that greater iridocorneal angle and higher aRISE were significantly associated with lower vault prediction error (p < 0.05). ICLGuru demonstrated useful postoperative vault predictions with performance comparable to existing machine learning and UBM-based nomograms, though it appeared to overestimate longer term vault in our cohort. The tool may be valuable in identifying eyes at risk for excessive vault. aRISE and iridocorneal angle were significant predictors of vault prediction error, supporting their importance in future ICL sizing models.

如何引用

AMA

Sanjana Molleti, Ethan J Lindberg, Hanna Pawlowski, Mina M Sitto, Nadim S Azar, Triston B Crook, et al. Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.. Clinical ophthalmology (Auckland, N.Z.). 2026; doi:10.2147/OPTH.S627979.

APA

Sanjana Molleti, Ethan J Lindberg, Hanna Pawlowski, Mina M Sitto, Nadim S Azar, Triston B Crook, et al (2026). Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.. Clinical ophthalmology (Auckland, N.Z.). https://doi.org/10.2147/OPTH.S627979

GB/T 7714

Sanjana Molleti, Ethan J Lindberg, Hanna Pawlowski, Mina M Sitto, Nadim S Azar, Triston B Crook, et al. Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.[J]. Clinical ophthalmology (Auckland, N.Z.), 2026 doi:10.2147/OPTH.S627979.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Clinical ophthalmology (Auckland, N.Z.) 的其他文献