优化超声乳腺癌症筛查的筛查间隔和BI-RADS管理途径:来自深圳的真实世界证据(2018-2023)
Optimising screening intervals and BI-RADS management pathways in ultrasound-based breast cancer screening: real-world evidence from Shenzhen (2018-2023).
Optimising screening intervals and BI-RADS management pathways in ultrasound-based breast cancer screening: real-world evidence from Shenzhen (2018-2023).
旨在确定在中国基于超声的乳腺癌筛查中,能够在癌症检出产出与召回负担之间取得平衡的筛查间隔及BI-RADS特异性管理路径。我们分析了2018至2023年间报告BI-RADS的1,694,838次超声检查。对于BI-RADS 1/2,通过召回率、癌症检出率(CDR)、阳性预测值(PPV)及早期比例评估筛查间隔。对于BI-RADS 0/3/4/5,我们评估了活检等待时间与PPV/早期比例之间的关联,并考察了BI-RADS 4A的影像学随访结局。在BI-RADS 1/2后的337,497个筛查间隔中,较长间隔与较高的CDR(每1,000例0.13-0.54)相关,但召回率更高(17.4%-22.1%)、PPV更低(61.1%-31.0%),而早期比例保持稳定。在产出与下游负担之间取得最佳平衡的间隔为:年龄≥40岁女性13-24个月,年龄<40岁女性25-36个月,在召回率无实质性增加的情况下实现了更高的检出产出和PPV。在1,949例BI-RADS 4/5活检中,4A的PPV较低(12.3%-25.0%),4B的PPV随活检延迟而显著下降(60.5%降至25.0%),4C/5则持续保持较高水平(>60%/>93%)。在BI-RADS 4A病灶中,64.7%(10,909/16,871)在随访期间出现影像学降级。在487例接受活检的BI-RADS 3病例中,延迟活检提高了PPV但未改变早期比例。建议40-64岁女性采用2年筛查间隔,<40岁者可延长至3年。BI-RADS 4B/4C/5应及时活检。BI-RADS 4A的高影像学降级率提示存在过度诊断,支持基于影像学的分诊,但需进一步验证。BI-RADS 3病灶首选影像学监测。
To identify screening intervals and BI-RADS-specific management pathways that balance cancer detection yield against recall burden in ultrasound-based breast cancer screening in China. We analysed 1,694,838 ultrasound examinations reported with BI-RADS (2018-2023). For BI-RADS 1/2, inter-screen intervals were evaluated by recall rate, cancer detection rate (CDR), positive predictive value (PPV), and early-stage proportion. For BI-RADS 0/3/4/5, we assessed associations between biopsy waiting time and PPV/early-stage proportion, and examined imaging follow-up outcomes for BI-RADS 4A. Among 337,497 screening intervals following BI-RADS 1/2, longer intervals were associated with higher CDR (0.13-0.54 per 1,000) but higher recall (17.4%-22.1%) and lower PPV (61.1%-31.0%), while early-stage proportion remained stable. The interval that best balanced yield and downstream burden was 13-24 months for women aged ≥ 40 years and 25-36 months for women aged < 40 years, achieving higher detection yield and PPV without a material increase in recall. Among 1,949 BI-RADS 4/5 biopsies, PPV was low for 4A (12.3%-25.0%), declined markedly with biopsy delay for 4B (60.5% to 25.0%), and remained consistently high for 4C/5 (> 60%/>93%). Among BI-RADS 4A lesions 64.7% (10,909/16,871) showed imaging downgrading during follow-up. In 487 BI-RADS 3 cases undergoing biopsy, delayed biopsy increased PPV without changing early-stage proportion. A 2-year screening interval is recommended for women aged 40-64 years, extendable to 3 years for those aged < 40. Prompt biopsy is warranted for BI-RADS 4B/4C/5. The high image downgrade rate of BI-RADS 4A suggests overestimation and supports imaging-based triage, requiring further validation. Imaging surveillance is preferable for BI-RADS 3 lesions.
Wanyi Sun, Huan Li, Xuelian Zhao, Shangying Hu, Haifeng Qi, Shuyan Jin, et al. Optimising screening intervals and BI-RADS management pathways in ultrasound-based breast cancer screening: real-world evidence from Shenzhen (2018-2023).. Breast cancer research and treatment. 2026; doi:10.1007/s10549-026-08045-w.
Wanyi Sun, Huan Li, Xuelian Zhao, Shangying Hu, Haifeng Qi, Shuyan Jin, et al (2026). Optimising screening intervals and BI-RADS management pathways in ultrasound-based breast cancer screening: real-world evidence from Shenzhen (2018-2023).. Breast cancer research and treatment. https://doi.org/10.1007/s10549-026-08045-w
Wanyi Sun, Huan Li, Xuelian Zhao, Shangying Hu, Haifeng Qi, Shuyan Jin, et al. Optimising screening intervals and BI-RADS management pathways in ultrasound-based breast cancer screening: real-world evidence from Shenzhen (2018-2023).[J]. Breast cancer research and treatment, 2026 doi:10.1007/s10549-026-08045-w.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出