确保房颤患者的肺静脉隔离持久:预防侧支热损伤和病变不一致

Ensuring durable pulmonary vein isolation for atrial fibrillation: prevention of collateral thermal injury and lesion inconsistency.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

肺静脉隔离(PVI)是心房颤动(AF)导管消融的基石。尽管技术取得了重大进步,但由于非持久性病变导致的肺静脉重连,心律失常复发仍然常见。实现持久性PVI需要在有效病变形成与预防 collateral 损伤之间取得平衡。本综述探讨了病变形成的生物物理决定因素、导致病变不一致性的机制,以及在最大限度减少 collateral 损伤的同时提高病变持久性的策略。文献通过结构化综述主要临床试验、观察性研究、机制研究和当代指南文件而确定,重点关注射频、冷冻球囊、激光球囊和脉冲场消融技术,以及用于病变评估和手术优化的新兴方法。持久性PVI不仅取决于能量来源,还取决于对导管-组织相互作用的精确控制、病变连续性以及个体化能量递送。脉冲场消融通过减少 collateral 热损伤显著提高了手术安全性;然而,持久性病变的形成仍然依赖于充分的组织接触和适当的能量递送。未来的进展将较少由新能源的开发驱动,而更多由能够提供实时病变验证和患者特异性消融策略的技术所推动。

Abstract

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). Despite major technological advances, arrhythmia recurrence remains common because of pulmonary vein reconnection caused by non-durable lesions. Achieving durable PVI requires balancing effective lesion formation with the prevention of collateral injury. This review examines the biophysical determinants of lesion formation, mechanisms responsible for lesion inconsistency, and strategies to improve lesion durability while minimizing collateral injury. The literature was identified through a structured review of major clinical trials, observational studies, mechanistic investigations, and contemporary guideline documents focusing on radiofrequency, cryoballoon, laser balloon, and pulsed field ablation technologies, together with emerging approaches for lesion assessment and procedural optimization. Durable PVI depends not only on the energy source but also on precise control of catheter-tissue interaction, lesion contiguity, and individualized energy delivery. Pulsed field ablation has substantially improved procedural safety by reducing collateral thermal injury; however, durable lesion formation remains dependent on adequate tissue contact and appropriate energy delivery. Future progress will be driven less by the development of new energy sources than by technologies capable of providing real-time lesion verification and patient-specific ablation strategies.

如何引用

AMA

Cristian Martignani, Alberto Spadotto, Maria Carelli, Lorenzo Bartoli, Andrea Angeletti, Igor Diemberger, et al. Ensuring durable pulmonary vein isolation for atrial fibrillation: prevention of collateral thermal injury and lesion inconsistency.. Expert review of cardiovascular therapy. 2026; doi:10.1080/14779072.2026.2714259.

APA

Cristian Martignani, Alberto Spadotto, Maria Carelli, Lorenzo Bartoli, Andrea Angeletti, Igor Diemberger, et al (2026). Ensuring durable pulmonary vein isolation for atrial fibrillation: prevention of collateral thermal injury and lesion inconsistency.. Expert review of cardiovascular therapy. https://doi.org/10.1080/14779072.2026.2714259

GB/T 7714

Cristian Martignani, Alberto Spadotto, Maria Carelli, Lorenzo Bartoli, Andrea Angeletti, Igor Diemberger, et al. Ensuring durable pulmonary vein isolation for atrial fibrillation: prevention of collateral thermal injury and lesion inconsistency.[J]. Expert review of cardiovascular therapy, 2026 doi:10.1080/14779072.2026.2714259.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI