使用锥束计算机断层扫描(CBCT)对尺骨远端骨折进行分类的可靠性和可重复性

Reliability and reproducibility of classification of distal ulnar fractures using cone beam computed tomography (CBCT).

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

尺骨远端骨折(DUF)的研究仍不充分,主要原因是其发病率低导致统计效能有限。现有的分类系统使用困难,且尚未针对锥形束计算机断层扫描(CBCT)等新型影像学方法进行验证。本研究旨在利用CBCT图像分析两种分类系统——内固定研究协会基金会/骨科创伤协会(AO/OTA)分类与Biyani分类——用于尺骨头及尺骨颈骨折的可靠性和可重复性。回顾性纳入2016至2022年间接受CBCT扫描的76例DUF患者。CBCT图像由6名不同医学专业和不同经验水平的观察者进行两次审阅。所有骨折均按照AO/OTA和Biyani分类系统进行分类。采用kappa值分析评估各分类系统的可靠性和可重复性。AO/OTA的可靠性为一般至中等,Light's ĸ值为0.41(95%置信区间[CI] 0.38-0.45);Biyani的可靠性为中等,Light's ĸ值为0.45(CI 0.42-0.49)。两种分类系统的可重复性均为高度一致,AO/OTA平均ĸ值为0.65(CI 0.49-0.80),Biyani的ĸ值为0.69(CI 0.60-0.79)。两种现有分类系统均被认为使用困难,且与现有骨折模式不符。在CBCT图像上,两者均表现出高度可重复性,但用于临床时可靠性不令人满意。

Abstract

Distal ulnar fractures (DUFs) remain under-investigated, primarily due to limited statistical power resulting from the low incidence. The present classification systems are difficult to use and are not validated for new radiological methods such as cone beam computed tomography (CBCT). We aimed to analyze the reliability and reproducibility of the 2 classification systems, Arbeitsgemeinschaft für Osteosynthesefragen foundation/Orthopaedic Trauma Association (AO/OTA) and Biyani, for fractures of the distal ulnar head and neck using CBCT images. 76 patients with DUF who underwent a CBCT scan during the years 2016-2022 were included retrospectively. The CBCT images were reviewed twice by 6 observers of different medical specialties and levels of experience. All fractures were classified according to AO/OTA and Biyani. The reliability and reproducibility of each classification system were analyzed using kappa value analysis. The reliability was fair to moderate for AO/OTA, Light's ĸ 0.41 (95% confidence interval [CI] 0.38-0.45) and moderate for Biyani, Light's ĸ 0.45 (CI 0.42-0.49), and the reproducibility was substantial for both AO/OTA, mean ĸ 0.65 (CI 0.49-0.80), and Biyani, ĸ 0.69 (CI 0.60-0.79). Both existing classification systems were perceived to be difficult to use and do not match existing fracture patterns. Using CBCT images, they both showed substantial reproducibility but not satisfactory reliability for clinical use.

如何引用

AMA

Linnéa Wretö, Lotta Fornander, Nina Kämmerling, Erika Nyman, Maria Moloney. Reliability and reproducibility of classification of distal ulnar fractures using cone beam computed tomography (CBCT).. Acta orthopaedica. 2026; doi:10.2340/17453674.2026.46344.

APA

Linnéa Wretö, Lotta Fornander, Nina Kämmerling, Erika Nyman, Maria Moloney (2026). Reliability and reproducibility of classification of distal ulnar fractures using cone beam computed tomography (CBCT).. Acta orthopaedica. https://doi.org/10.2340/17453674.2026.46344

GB/T 7714

Linnéa Wretö, Lotta Fornander, Nina Kämmerling, Erika Nyman, Maria Moloney. Reliability and reproducibility of classification of distal ulnar fractures using cone beam computed tomography (CBCT).[J]. Acta orthopaedica, 2026 doi:10.2340/17453674.2026.46344.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Acta orthopaedica 的其他文献