超声皮下组织参数对乳腺癌相关淋巴水肿综合消肿治疗的反应性

Responsiveness of Ultrasonographic Subcutaneous Tissue Parameters to Complex Decongestive Therapy in Breast Cancer-Related Lymphedema.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

超声皮下组织参数此前已被用作评估乳腺癌相关淋巴水肿(BCRL)的结局指标。然而,其检测临床有意义变化的能力——即反应度——尚未得到检验。本研究旨在探讨超声皮下组织厚度测量、皮下回声性(SEG)及皮下无回声间隙(SEFS)变化的反应度。40例国际淋巴学会2-3期单侧淋巴水肿患者接受第一阶段综合消肿治疗,每周3次,持续4周。于治疗前后评估超声皮下组织厚度、SEG和SEFS,以及周径测量、肢体体积和疼痛、沉重感、紧绷感的视觉模拟量表评分。观察到症状显著改善(< 0.0001)。水肿体积及百分比显著下降(= 0.012和= 0.006)。皮下组织厚度在上臂内侧、内上髁和腕部显著降低(< 0.02),表现出最高的反应度(效应量= 1.74)。相比之下,SEG和SEFS的变化仅在有限部位具有统计学显著性,总体反应度为小至可忽略;然而,SEFS在腕部——基线游离液体积聚最多的部位——表现出相对较高的反应度。周径和体积测量的反应度较低。皮下组织厚度是BCRL中最敏感的超声标志物,其次是症状评分。SEG和SEFS总体反应度有限,尽管SEFS在腕部仍具有意义。水肿体积及百分比的反应度高于整体肢体体积和周径测量。将皮下厚度与水肿特异性评估及症状评估相结合,可能增强对治疗结局的监测。

Abstract

Ultrasonographic subcutaneous tissue parameters have previously been used as outcome measures in the evaluation of breast cancer-related lymphedema (BCRL). However, their ability to detect clinically meaningful changes-referred to as responsiveness-has not yet been examined. This study aimed to investigate the responsiveness of ultrasonographic subcutaneous tissue thickness measurements, subcutaneous echogenicity (SEG), and subcutaneous echo-free space (SEFS) changes. Forty patients with International Society of Lymphology Stage 2-3 unilateral lymphedema underwent phase 1 complex decongestive therapy three times weekly for 4 weeks. Ultrasonographic subcutaneous tissue thickness, SEG, and SEFS, alongside circumferential measurements, limb volume, and visual analog scale scores for pain, heaviness, and tightness, were evaluated pre- and posttreatment. Significant symptomatic improvement was observed ( < 0.0001). Edema volume and percentage decreased significantly ( = 0.012 and = 0.006). Subcutaneous tissue thickness significantly decreased at the upper arm medial, medial epicondyle, and wrist ( < 0.02), demonstrating the highest responsiveness (effect size = 1.74). In contrast, changes in SEG and SEFS were statistically significant only at limited sites and showed small to negligible responsiveness overall; however, SEFS showed comparatively higher responsiveness at the wrist, the site with the greatest baseline free-fluid accumulation. Circumferential and volumetric measures showed low responsiveness. Subcutaneous tissue thickness was the most sensitive ultrasonographic marker in BCRL, followed by symptom scores. SEG and SEFS showed limited overall responsiveness, although SEFS remained meaningful at the wrist. Edema volume and percentage showed greater responsiveness than overall limb volume and circumferential measurements. Integrating subcutaneous thickness with edema-specific and symptom assessment may enhance monitoring of therapeutic outcomes.

如何引用

AMA

Esra Giray, Esra Nur Türkmen, İlker Yağcı, Gülseren Akyüz. Responsiveness of Ultrasonographic Subcutaneous Tissue Parameters to Complex Decongestive Therapy in Breast Cancer-Related Lymphedema.. Lymphatic research and biology. 2026; doi:10.1177/15578585261473403.

APA

Esra Giray, Esra Nur Türkmen, İlker Yağcı, Gülseren Akyüz (2026). Responsiveness of Ultrasonographic Subcutaneous Tissue Parameters to Complex Decongestive Therapy in Breast Cancer-Related Lymphedema.. Lymphatic research and biology. https://doi.org/10.1177/15578585261473403

GB/T 7714

Esra Giray, Esra Nur Türkmen, İlker Yağcı, Gülseren Akyüz. Responsiveness of Ultrasonographic Subcutaneous Tissue Parameters to Complex Decongestive Therapy in Breast Cancer-Related Lymphedema.[J]. Lymphatic research and biology, 2026 doi:10.1177/15578585261473403.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Lymphatic research and biology 的其他文献