B型囊内髁突头骨折固定的最佳螺钉方向:一项对比性有限元分析
Optimal Screw Orientation for Fixation of Type B Intracapsular Condylar Head Fractures: A Comparative Finite Element Analysis.
Optimal Screw Orientation for Fixation of Type B Intracapsular Condylar Head Fractures: A Comparative Finite Element Analysis.
尽管髁突头骨折的螺钉固定日益受到青睐,但最佳置钉方向策略仍缺乏明确定义,指导术中决策的证据有限。本研究比较了四种螺钉方向在B型髁突骨折固定中的生物力学行为。基于CT和MRI数据重建三维颌面部模型,并纳入虚拟B型骨折。通过十二次仿真模拟,在三种功能性咬合场景下测试了四种不同的螺钉方向。分析了螺钉、骨块、关节盘、关节面、关节结节及下颌骨中的应力分布,并记录了位移情况。第一种方向(两枚螺钉相互平行且与骨折线呈90°)显示螺钉应力最低(前部:91.8 MPa;骨折侧:113.7 MPa),而第四种方向在非骨折侧咬合下表现最佳(175.3 MPa)。相比之下,第三种方向导致螺钉应力最高(357.0 MPa)。第一种和第四种方向使骨折侧髁突表面峰值应力最小化,而第二种和第三种方向则表现出更高的应力集中。所有方向下骨块间位移均< 0.06 mm,其中第一种方向展现出更优的微动控制及最低的骨应力(38.2 MPa)。第一种方向在生物力学上最优,可在维持结构稳定性的同时最小化内固定物应力。当存在手术入路或解剖限制时,第四种方向是可行的替代方案。相反,第三种方向应予以避免,因其过度的应力集中易导致结构疲劳失效或骨吸收。
Although screw fixation of condylar head fractures is increasingly favored, optimal orientation strategies remain poorly defined, with limited evidence guiding intraoperative decision-making. This study compared the biomechanical behavior of four screw orientations in the fixation of type B condylar fractures. A 3D maxillofacial model was reconstructed from CT and MRI data, incorporating a virtual type B fracture. Twelve simulations tested four distinct screw orientations across three functional occlusal biting scenarios. The stress distributions were analyzed in the screws, bone fragments, articular disc, articular surface, articular tubercle, and mandibular bone. The displacement was also recorded. While the first orientation (two screws parallel to each other and at 90° to the fracture line) showed the lowest screw stress (anterior: 91.8 MPa; fractured side: 113.7 MPa), the fourth performed best under non-fractured side biting (175.3 MPa). In contrast, the third orientation led to the highest stress on the screws (357.0 MPa). The first and fourth orientations minimized peak stress on the fractured-side condylar surface, whereas the second and third exhibited higher stress concentrations. Interfragmentary displacement remained < 0.06 mm across all orientations, with the first demonstrating superior micromotion control and the lowest bone stress (38.2 MPa). The first orientation is biomechanically optimal, minimizing hardware stress while maintaining construct stability. The fourth orientation is a viable alternative when surgical access or anatomical constraints exist. Conversely, the third orientation should be avoided due to excessive stress concentrations that predispose the construct to fatigue failure or bone resorption.
Sadam Ahmed Elayah, Ruitao Zhang, Wenzhong Hu, Xinzhe Gao, Ruijun Song, Jing Huang, et al. Optimal Screw Orientation for Fixation of Type B Intracapsular Condylar Head Fractures: A Comparative Finite Element Analysis.. Dental traumatology : official publication of International Association for Dental Traumatology. 2026; doi:10.1111/edt.70106.
Sadam Ahmed Elayah, Ruitao Zhang, Wenzhong Hu, Xinzhe Gao, Ruijun Song, Jing Huang, et al (2026). Optimal Screw Orientation for Fixation of Type B Intracapsular Condylar Head Fractures: A Comparative Finite Element Analysis.. Dental traumatology : official publication of International Association for Dental Traumatology. https://doi.org/10.1111/edt.70106
Sadam Ahmed Elayah, Ruitao Zhang, Wenzhong Hu, Xinzhe Gao, Ruijun Song, Jing Huang, et al. Optimal Screw Orientation for Fixation of Type B Intracapsular Condylar Head Fractures: A Comparative Finite Element Analysis.[J]. Dental traumatology : official publication of International Association for Dental Traumatology, 2026 doi:10.1111/edt.70106.