描述经皮螺钉固定耻骨联合分离作为切开复位钢板固定替代方案的技术。耻骨联合分离≥25 mm的骨盆环骨折(前后挤压[APC]II型、侧方挤压[LC]I型和II型)。若闭合复位失败则需切开复位。肥胖或疝可能妨碍螺钉置入。使用Weber钳经皮进行复位。在C臂成像引导下,第一根导针经皮从一侧耻骨结节穿入并跨越耻骨联合。在置入7.3 mm空心螺钉之前,先用空心钻头钻开近侧皮质。第二枚螺钉以同样方式从对侧置入。可采用V形配置(上位螺钉横向置入、下位螺钉斜向置入)或X形配置(两枚螺钉均斜向置入并在耻骨联合处交叉)。血栓预防6-12周。术后拍摄骨盆正位、入口位和出口位X线片。若为双侧后环损伤,患者应保持6周不负重。若后环损伤为单侧,对侧腿可完全负重。术后6周应随访拍摄X线片并可开始负重。术后6个月再次随访。作者已实施并记录8例采用该技术治疗的病例。1例患者为开放性骨折,并发生与内固定物相关的感染,需行翻修手术。1例患者未能获得随访资料。4例可见螺钉松动或断裂的影像学征象;然而,所有患者均显示良好结局,且无需取出内固定物。
Describe percutaneous screw fixation of symphyseal disruption as an alternative to open reduction and plate fixation. Pelvic ring fractures with symphyseal disruption ≥ 25 mm (anteroposterior compression [APC] type II, lateral compression [LC] type I and II). Open reduction is required if closed reduction fails. Obesity or hernia may hinder screw insertion. Reduction with a Weber clamp placed percutaneously. Using C‑arm imaging, the first guide wire is introduced percutaneously from one pubic tubercle across the symphysis. The near cortex is drilled with a cannulated drill bit prior to inserting the 7.3 mm cannulated screw. The second screw is placed in the same fashion from the contralateral side. Either a V-configuration with the superior screw placed in a transverse direction and the inferior screw oblique, or an X‑configuration with both screws oblique and crossing at the symphysis can be used. Thromboprophylaxis for 6-12 weeks. Obtain postoperative x‑rays with anteroposterior, inlet and outlet views. In case of bilateral posterior injury, the patient should remain nonweight-bearing for 6 weeks. If posterior injury is unilateral, the contralateral leg may fully weight-bear. Follow-up with x‑rays should be obtained 6 weeks postoperatively and weight-bearing can commence. Additional follow-up 6 months postoperatively. The authors have performed and documented eight cases treated with this technique. One patient had an open fracture and developed an implant-associated infection requiring revision surgery. Follow-up information for one patient could not be obtained. Radiological signs of screw loosening or breakage was visible in four cases; however, all patients showed good outcomes, and no implant removal was required.
Nicole M van Veelen, Julia J Chan, Björn-Christian Link, Peter D Bates. Percutaneous screw fixation of pubic symphysis diastasis.. Operative Orthopadie und Traumatologie. 2026; doi:10.1007/s00064-026-00952-x.
Nicole M van Veelen, Julia J Chan, Björn-Christian Link, Peter D Bates (2026). Percutaneous screw fixation of pubic symphysis diastasis.. Operative Orthopadie und Traumatologie. https://doi.org/10.1007/s00064-026-00952-x
Nicole M van Veelen, Julia J Chan, Björn-Christian Link, Peter D Bates. Percutaneous screw fixation of pubic symphysis diastasis.[J]. Operative Orthopadie und Traumatologie, 2026 doi:10.1007/s00064-026-00952-x.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出