在临床环境中对四肢瘫痪和高位截瘫患者使用atalante外骨骼的回顾性安全性评估

Retrospective safety evaluation of the atalante exoskeleton in a clinical setting in patients with tetraplegia and high paraplegia.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

回顾性研究。评估Atalante外骨骼在四肢瘫及高位截瘫患者中的安全性。法国三家住院康复中心。分析了33例住院患者的数据,其中四肢瘫12例运动完全性损伤(美国脊髓损伤协会损伤量表(AIS)A级或B级)、10例运动不完全性损伤(AIS C级或D级),高位截瘫(T4水平或以上;10例运动完全性损伤、1例运动不完全性损伤),脊髓损伤(SCI)后平均时间2.6年(19例损伤后<12个月),这些患者均完成了至少一次Atalante外骨骼训练。主要结局为通过报告的器械相关不良事件(AE)进行的安全性评估。次要结局包括疼痛(数字疼痛评定量表)、痉挛(Ashworth量表)、步行能力(WISCI-II)及外骨骼训练数据。参与者接受外骨骼训练的中位次数为7.5次(IQR:3-22.8),中位直立时间为22.4分钟(IQR:18-26.9),完成583.0步(IQR:347.0-854.0)。所有训练中每次训练的不良事件估计发生率为0.63%,95%置信区间为-0.56至1.81%。1例患者发生1起轻微不良事件,包括低血压、疲劳和头晕,导致训练中止。未报告治疗相关疼痛或骨折。关于次要结局,痉挛状态保持不变,而11例不完全性脊髓损伤患者的WISCI-II评分观察到积极变化。经个体获益-风险评估后,Atalante外骨骼可安全用于高位脊髓损伤患者的临床环境。Wandercraft。

Abstract

Retrospective study. To evaluate the safety of the Atalante exoskeleton in patients with tetraplegia and high paraplegia. Three inpatient rehabilitation centers in France. Data from thirty-three inpatients with tetraplegia (12 motor complete (American Spinal Injury Association Impairment Scale (AIS) grade A or B), 10 motor incomplete (AIS C or D)) and high paraplegia (at or above T4 level; 10 motor complete and 1 motor incomplete) and an average time since Spinal Cord Injury (SCI) of 2.6 years (19 individuals < 12 months after injury), who completed at least one session of training with the Atalante exoskeleton, were analyzed. The primary outcome was the safety assessment through reported device-related adverse effects (AE). Secondary outcomes included pain (Numeric Pain Rating Scale), spasticity (Ashworth scale), walking ability (WISCI-II), and exoskeleton session data. Participants underwent a median of 7.5 (IQR: 3-22.8) exoskeleton training sessions, with a median verticalization duration of 22.4 min (IQR: 18-26.9) and 583.0 steps (IQR: 347.0-854.0) performed. The estimated rate of AEs per session across all sessions was 0.63%, with a 95% confidence interval ranging from -0.56 to 1.81%. One minor AE occurred in one patient, involving hypotension, fatigue and dizziness, leading to session discontinuation. No therapy-related pain or fracture was reported. Regarding secondary outcomes, spasticity remained unchanged while positive changes were observed in WISCI-II scores in 11 patients with incomplete SCI. After individual benefit-risk assessment, the Atalante exoskeleton can be safely used in a clinical setting for high SCI patients. Wandercraft.

如何引用

AMA

Jean-Gabriel Previnaire, Héloise Baillet, Jean-François Bel, Vincent Péan, Céline Cuenot. Retrospective safety evaluation of the atalante exoskeleton in a clinical setting in patients with tetraplegia and high paraplegia.. Spinal cord series and cases. 2026; doi:10.1038/s41394-026-00744-2.

APA

Jean-Gabriel Previnaire, Héloise Baillet, Jean-François Bel, Vincent Péan, Céline Cuenot (2026). Retrospective safety evaluation of the atalante exoskeleton in a clinical setting in patients with tetraplegia and high paraplegia.. Spinal cord series and cases. https://doi.org/10.1038/s41394-026-00744-2

GB/T 7714

Jean-Gabriel Previnaire, Héloise Baillet, Jean-François Bel, Vincent Péan, Céline Cuenot. Retrospective safety evaluation of the atalante exoskeleton in a clinical setting in patients with tetraplegia and high paraplegia.[J]. Spinal cord series and cases, 2026 doi:10.1038/s41394-026-00744-2.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI