开发人工智能以检测假阳性检测,从而管理结肠镜检查中人工智能的准确性
Development of an Artificial Intelligence for Detecting False Positive Detection to Manage the Accuracy of Artificial Intelligence in Colonoscopy.
Development of an Artificial Intelligence for Detecting False Positive Detection to Manage the Accuracy of Artificial Intelligence in Colonoscopy.
假阳性检测(false positive detection, FPD)是临床中一项亟待解决的挑战,对于确保人工智能(artificial intelligence, AI)安全有效地整合到结肠镜检查中至关重要。本研究旨在开发一种新型AI系统以量化FPD,并比较两种市售AI平台之间的FPD发生率。2022年10月至2025年5月期间,从78例患者的结肠镜检查视频中共采集436,637帧图像:其中38个视频(340,121帧图像)使用CAD EYE(富士胶片,日本东京),40个视频(96,516帧图像)使用EndoBRAIN(奥林巴斯,日本东京)。利用这些图像,应用YOLOv8卷积神经网络构建用于FPD分析的原始AI模型:ARBS-YOLOv8(采用主动学习)。使用CAD EYE和EndoBRAIN临床视频验证该模型的性能。在CAD EYE验证中,ARBS-YOLOv8的准确率、灵敏度、特异度、精确率和F1分数分别为99.22%、99.51%、99.97%、99.96%和99.90%。在EndoBRAIN验证中,ARBS-YOLOv8的结果分别为99.97%、99.84%、99.97%、99.97%和99.90%。FPD检测的假阳性率和假阴性率在CAD EYE中仅为0.04%和0.03%,在EndoBRAIN中为0.03%和0.03%。在采集的13个临床视频(7个CAD EYE,6个EndoBRAIN)中,ARBS-YOLOv8识别出CAD EYE的总FPD率为8.08%,EndoBRAIN为2.47%,两者差异具有统计学意义(p<0.001)。我们开发了首个能够在两种市售AI平台下客观测量结肠镜检查过程中FPD的AI系统。该模型验证了CAD EYE与EndoBRAIN之间的性能差异,为降低FPD和实现安全的AI内镜检查提供了依据。
False positive detection (FPD) is a clinically relevant challenge that must be solved to ensure the safe and effective integration of artificial intelligence (AI) into colonoscopy. This study aimed to develop a novel AI system for quantifying FPD and to compare FPD rates between two commercially available AI platforms. From October 2022 to May 2025, a total of 436,637 images were collected from 78 patient colonoscopy videos: 38 videos (340,121 images) using CAD EYE (Fujifilm, Tokyo, Japan) and 40 videos (96,516 images) using EndoBRAIN (Olympus, Tokyo, Japan). Using these images, YOLOv8 convolutional neural networks were applied to construct original AI model for FPD analysis: ARBS-YOLOv8 (with active learning). The performance of the model was validated using the CAD EYE and EndoBRAIN clinical videos. For CAD EYE validation, ARBS-YOLOv8 achieved an accuracy, sensitivity, specificity, precision, and F1 score of 99.22%, 99.51%, 99.97%, 99.96%, and 99.90%, respectively. For EndoBRAIN validation, the ARBS-YOLOv8 results were 99.97%, 99.84%, 99.97%, 99.97%, and 99.90%, respectively. The false-positive and false-negative rates of FPD detection were only 0.04% and 0.03% for CAD EYE and 0.03% and 0.03% for EndoBRAIN. In 13 collected clinical videos (7 CAD EYE, 6 EndoBRAIN), ARBS-YOLOv8 identified total FPD rates of 8.08% for CAD EYE and 2.47% for EndoBRAIN, showing a significant difference (p<0.001). We developed the first AI system capable of objectively measuring FPD during colonoscopy under two commercially available AI platforms. The model validated performance differences between CAD EYE and EndoBRAIN, providing a basis for FPD reduction and safe AI endoscopy.
Naohisa Yoshida, Ruiyao Zhang, Yasutaka Morimoto, Takeshi Yasuda, Reo Kobayashi, Naoto Iwai, et al. Development of an Artificial Intelligence for Detecting False Positive Detection to Manage the Accuracy of Artificial Intelligence in Colonoscopy.. Journal of the anus, rectum and colon. 2026; doi:10.23922/jarc.2025-112.
Naohisa Yoshida, Ruiyao Zhang, Yasutaka Morimoto, Takeshi Yasuda, Reo Kobayashi, Naoto Iwai, et al (2026). Development of an Artificial Intelligence for Detecting False Positive Detection to Manage the Accuracy of Artificial Intelligence in Colonoscopy.. Journal of the anus, rectum and colon. https://doi.org/10.23922/jarc.2025-112
Naohisa Yoshida, Ruiyao Zhang, Yasutaka Morimoto, Takeshi Yasuda, Reo Kobayashi, Naoto Iwai, et al. Development of an Artificial Intelligence for Detecting False Positive Detection to Manage the Accuracy of Artificial Intelligence in Colonoscopy.[J]. Journal of the anus, rectum and colon, 2026 doi:10.23922/jarc.2025-112.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出