多过敏原同步检测中粗提物与组分过敏原的一致性:一项大规模回顾性分析

Concordance between crude extract and component allergens in a multiple allergen simultaneous test: a large-scale retrospective analysis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

多重过敏原同步检测(MAST)日益整合粗提物与分子组分过敏原用于特异性IgE检测。然而,关于这两种方法之间诊断一致性的系统性数据仍然有限。我们在一个大型临床实验室队列中,使用MAST panel评估了粗提物与相应组分过敏原结果之间的一致性。我们回顾性分析了某高通量转诊实验室在两个月期间去重后的MAST结果。针对29种粗提物过敏原与48种相应组分过敏原的配对,采用2级或以上(≥0.70 IU/mL)作为 cutoff 评估阳性率。一致性定义为粗提物和至少一种组分过敏原均为阳性,或两者均为阴性。采用符合率和Cohen's kappa系数评估一致性。共纳入19,949例患者。最高阳性率见于(31.8%)、(29.9%)、rDer f 2(24.2%)和猫上皮(12.2%)。大多数过敏原配对的总体符合率超过90%,主要由高阴性符合率驱动。Cohen's kappa显示十种过敏原具有实质性一致性(κ ≥ 0.6),包括猫皮屑和桦树花粉,而八种过敏原包括和牛奶则因粗提物结果阳性而组分过敏原阳性率低,显示一致性较差(κ < 0.1)。MAST中粗提物与组分过敏原检测之间的诊断一致性因过敏原来源不同而差异显著。这些发现强调,临床实验室在报告包含组分过敏原的MAST结果时,需要制定过敏原特异性解读指南。

Abstract

Multiple allergen simultaneous tests (MAST) increasingly incorporate both crude extract and molecular component allergens for specific IgE testing. However, systematic data on the diagnostic concordance between these two approaches remain limited. We evaluated the agreement between crude extract and corresponding component allergen results using a MAST panel in a large clinical laboratory cohort. We retrospectively analysed deduplicated MAST results from a high-volume referral laboratory over a two-month period. For 29 crude extract allergens paired with 48 corresponding component allergens, positivity rates were assessed using a cutoff of class 2 or higher (≥0.70 IU/mL). Concordance was defined as both crude extract and at least one component allergen being positive, or both being negative. Agreement was evaluated using percent agreement and Cohen's kappa coefficient. A total of 19,949 patients were included. The highest positivity rates were observed for (31.8%), (29.9%), rDer f 2 (24.2%), and cat epithelium (12.2%). Overall percent agreement exceeded 90% for most allergen pairs, primarily driven by high negative agreement. Cohen's kappa revealed substantial agreement (κ ≥ 0.6) for ten allergens including , cat dander, and birch pollen, whereas eight allergens including and milk showed poor agreement (κ < 0.1) due to low component allergen positivity despite positive crude extract results. Diagnostic concordance between crude extract and component allergen testing in MAST varies substantially across allergen sources. These findings underscore the need for allergen-specific interpretation guidelines when reporting MAST results incorporating component allergens in clinical laboratories.

如何引用

AMA

Hyejin Ryu, Kuenyoul Park, Kina Kim, Dohsik Minn. Concordance between crude extract and component allergens in a multiple allergen simultaneous test: a large-scale retrospective analysis.. British journal of biomedical science. 2026; doi:10.3389/bjbs.2026.16596.

APA

Hyejin Ryu, Kuenyoul Park, Kina Kim, Dohsik Minn (2026). Concordance between crude extract and component allergens in a multiple allergen simultaneous test: a large-scale retrospective analysis.. British journal of biomedical science. https://doi.org/10.3389/bjbs.2026.16596

GB/T 7714

Hyejin Ryu, Kuenyoul Park, Kina Kim, Dohsik Minn. Concordance between crude extract and component allergens in a multiple allergen simultaneous test: a large-scale retrospective analysis.[J]. British journal of biomedical science, 2026 doi:10.3389/bjbs.2026.16596.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

British journal of biomedical science 的其他文献