深度学习和基于CFD的CT-FFR在不同血管、心动周期和中心的比较诊断性能与稳定性
Comparative diagnostic performance and stability of deep learning- and CFD-based CT-FFR across vessels, cardiac phases, and centers.
Comparative diagnostic performance and stability of deep learning- and CFD-based CT-FFR across vessels, cardiac phases, and centers.
尽管基于深度学习(DL)和计算流体力学(CFD)的CT衍生血流储备分数(CT-FFR)越来越多地用于功能性缺血评估,但关于两者在同一队列中诊断稳定性的直接多中心头对头证据仍然有限。本研究旨在比较基于DL与基于CFD的CT-FFR在不同冠状动脉分支、心动周期、临床中心及缺血阳性灰区病变中,以有创FFR为参照的诊断性能和稳健性。我们回顾性分析了来自两个中心的220例患者(277支血管),这些患者均接受了冠状动脉CTA和有创FFR检查。CT-FFR采用具有代表性的商业化DL和CFD算法计算。以有创FFR为参考标准评估诊断性能。针对目标血管、重建期相、成像中心和灰区病变进行亚组分析。DL与CFD显示出较高且相似的诊断性能。DL的AUC为0.90(95% CI:0.88-0.93),CFD为0.89(95% CI:0.86-0.92),差异无统计学意义(> 0.05)。两种方法均与有创FFR强相关(DL:rho = 0.71;CFD:rho = 0.68;均 < 0.001)。亚组分析显示,在不同血管、心动周期和中心之间性能稳定(均 > 0.05)。在灰区病变中,DL与CFD显示出相当的正确分类率(86.4% vs. 84.6%,= 0.690)和假阴性率(13.6% vs. 15.4%,= 0.690)。基于DL和基于CFD的CT-FFR在检测血流动力学显著狭窄方面显示出相似且较强的诊断性能。这些发现支持将两种方法作为无创功能评估工具用于特定患者的潜在价值。
Although CT-derived FFR (CT-FFR) based on deep learning (DL) and computational fluid dynamics (CFD) is increasingly used for functional ischemia assessment, direct head-to-head multi-center evidence regarding their diagnostic stability in the same cohort remains limited. This study aimed to compare the diagnostic performance and robustness of DL-based versus CFD-based CT-FFR against invasive FFR across coronary branches, cardiac phases, clinical centers, and ischemia-positive gray-zone lesions. We retrospectively analyzed 220 patients (277 vessels) who underwent coronary CTA and invasive FFR from two centers. CT-FFR was calculated using representative commercial DL-based and CFD-based algorithms. Diagnostic performance was evaluated using invasive FFR as the reference standard. Subgroup analyses were performed for target vessels, reconstruction phases, imaging centers, and gray-zone lesions. DL and CFD showed high and similar diagnostic performance. The AUC was 0.90 (95% CI: 0.88-0.93) for DL and 0.89 (95% CI: 0.86-0.92) for CFD, and the difference was not significant ( > 0.05). Both methods were strongly correlated with invasive FFR (rho = 0.71 for DL; rho = 0.68 for CFD; both < 0.001). The subgroup analyses showed stable performance across vessels, cardiac phases, and centers (all > 0.05). In gray-zone lesions, DL and CFD showed comparable correct classification rates (86.4% vs. 84.6%, = 0.690) and false-negative rates (13.6% vs. 15.4%, = 0.690). DL-based and CFD-based CT-FFR showed similar and strong diagnostic performance for detecting hemodynamically significant stenosis. These findings support the potential use of both approaches as non-invasive functional assessment tools in selected patients.
Bin Zhou, Yang Guo, Dongchuang Guo, Su Qian, Zhezhe Huang, Yangfan Zhang, et al. Comparative diagnostic performance and stability of deep learning- and CFD-based CT-FFR across vessels, cardiac phases, and centers.. Frontiers in cardiovascular medicine. 2026; doi:10.3389/fcvm.2026.1883012.
Bin Zhou, Yang Guo, Dongchuang Guo, Su Qian, Zhezhe Huang, Yangfan Zhang, et al (2026). Comparative diagnostic performance and stability of deep learning- and CFD-based CT-FFR across vessels, cardiac phases, and centers.. Frontiers in cardiovascular medicine. https://doi.org/10.3389/fcvm.2026.1883012
Bin Zhou, Yang Guo, Dongchuang Guo, Su Qian, Zhezhe Huang, Yangfan Zhang, et al. Comparative diagnostic performance and stability of deep learning- and CFD-based CT-FFR across vessels, cardiac phases, and centers.[J]. Frontiers in cardiovascular medicine, 2026 doi:10.3389/fcvm.2026.1883012.