临近既有结构的倾斜支护结构土压力分析

Earth pressure analysis of inclined support structures adjacent to existing structures.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

本研究通过室内物理模型试验与理论推导相结合的方法,研究了邻近既有结构的倾斜支护结构上的土压力。在宽高比恒定为0.95的条件下,开展了五组模型试验,支护倾角分别为0°、5°、10°、15°和20°。采用粒子图像测速技术(PIV)和多点土压力监测,揭示了有限土体内破坏面的发展规律及墙后土压力的分布特征。基于直线破坏面和圆弧主应力轨迹的假定,将有限土体划分为若干区域,对各区域水平微分单元建立力平衡方程,推导了土压力强度、合力及合力作用点的理论模型。理论结果与试验结果总体吻合良好,较好地反映了倾斜支护条件下有限土体内被动土压力的分布特征。特别是,理论预测值与实测值在土体中下部的主压区吻合较好。由于局部墙土分离、无黏性砂不能传递拉应力以及墙土接触松弛等原因,上部监测点的实测土压力明显偏低。在试验验证范围内,随着支护倾角的增大,土压力合力减小,其作用点总体向上移动;相反,土体内摩擦角的增大则使作用点向下移动。本研究结果可为邻近既有结构工程中倾斜支护结构的设计提供理论参考。

Abstract

This study investigates the earth pressure acting on inclined support structures adjacent to existing structures by combining laboratory physical model tests with theoretical derivation. Five groups of model tests were conducted at a constant width-to-height ratio of 0.95, with support inclination angles of 0°, 5°, 10°, 15°, and 20°. Particle image velocimetry (PIV) and multi-point earth pressure monitoring were employed to reveal the failure surface development in the finite soil mass and the distribution characteristics of earth pressure behind the wall. Based on the assumptions of straight failure surfaces and circular-arc major principal stress trajectories, the finite soil mass was divided into several zones. Force equilibrium equations were established for horizontal differential elements in each zone, and theoretical models for earth pressure intensity, resultant force, and the point of application of the resultant force were derived. The theoretical results were generally in good agreement with the experimental results and reasonably reflected the distribution characteristics of passive earth pressure in the finite soil mass under inclined support conditions. In particular, the theoretical predictions were in good agreement with the measured values in the principal compression zone in the middle and lower portions of the soil mass. The measured earth pressures at the upper monitoring points were markedly lower because of local wall-soil separation, the inability of cohesionless sand to transmit tensile stress, and wall-soil contact relaxation. Within the experimental validation range, the resultant earth pressure decreased and its point of application generally shifted upward as the support inclination angle increased. In contrast, an increase in the soil friction angle caused the point of application to shift downward. The findings of this study can provide a theoretical reference for the design of inclined support structures in projects adjacent to existing structures.

如何引用

AMA

Chucai Peng, Xuhui Fu, Weiwei Wang, Rui Yin. Earth pressure analysis of inclined support structures adjacent to existing structures.. PloS one. 2026; doi:10.1371/journal.pone.0354972.

APA

Chucai Peng, Xuhui Fu, Weiwei Wang, Rui Yin (2026). Earth pressure analysis of inclined support structures adjacent to existing structures.. PloS one. https://doi.org/10.1371/journal.pone.0354972

GB/T 7714

Chucai Peng, Xuhui Fu, Weiwei Wang, Rui Yin. Earth pressure analysis of inclined support structures adjacent to existing structures.[J]. PloS one, 2026 doi:10.1371/journal.pone.0354972.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

PloS one 的其他文献