使用1.1毫米探头对间质性肺病患者进行经支气管肺冷冻活检的诊断率和并发症发生率
Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease.
Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease.
经支气管肺冷冻活检(TBLC)采用1.9或2.4 mm接触式冷冻探头在间质性肺疾病(ILD)中的广泛开展受到高出血风险的限制。近期研究表明,经传统支气管镜使用1.1 mm冷冻探头可获得与较大探头相当的诊断率,同时保持良好的安全性。关于1.1 mm接触式冷冻探头诊断ILD的研究存在缺陷且结论相互矛盾。本研究旨在描述使用1.1 mm接触式冷冻探头对ILD患者行TBLC的并发症发生率、诊断率及提高诊断率的相关因素。该回顾性队列研究纳入了在德克萨斯大学西南医学中心(UTSW)ILD门诊登记库中前瞻性识别、于2022至2026年间接受TBLC的患者。记录操作特征。为患者分配TBLC前诊断、TBLC后诊断及最终诊断。本研究表明,在BAL基础上加用1.1 mm探头的TBLC可显著提高诊断率,气胸风险为11%,出血风险为6.5%。BAL联合TBLC在27例(43.5%)患者中具有诊断价值,并使27例(43.5%)患者的诊断发生改变。TBLC取样数量与更高的诊断率相关。本研究中1.1 mm接触式探头的诊断率和并发症发生率高于既往TBBx研究报告,但低于1.9和2.4 mm接触式探头,尽管本研究中无直接对照组。为提高操作诊断率,应对多个肺叶进行活检并增加取样数量。
Widespread adoption of transbronchial lung cryobiopsy (TBLC) using a 1.9 or 2.4 mm touch cryoprobe in interstitial lung disease (ILD) has been limited by high bleeding risk. Recent studies have demonstrated that the 1.1 mm cryoprobe via conventional bronchoscope may achieve diagnostic yields comparable to larger probes while maintaining a favorable safety profile. Studies of the 1.1 mm touch cryoprobe in the diagnosis of ILD have been flawed and conflicting. The aim of this study is to describe the complication rate, diagnostic yield, and factors that increase diagnostic yield of TBLC using a 1.1 mm touch cryoprobe in patients with ILD. The retrospective cohort study included patients that were prospectively identified in the ILD clinic registry at University of Texas Southwestern Medical Center (UTSW) who underwent TBLC from 2022-2026. Procedural characteristics were recorded. Patients were assigned a pre-TBLC, post-TBLC, and final diagnosis. This study demonstrates that TBLC using a 1.1 mm probe added to BAL significantly increases diagnostic yield with an 11% risk of pneumothorax and a 6.5% risk of bleeding. The combination of BAL and TBLC was diagnostic in 27 (43.5%) of patients and led to a change in diagnosis in 27 (43.5%) of patients. The number of TBLC samples taken is associated with a higher diagnostic yield. The diagnostic yield and complication rates of the 1.1 mm touch probe in our study are higher than previously reported studies with TBBx but lower than 1.9 and 2.4 mm touch probes, though there was no direct comparison group in our study. To increase yield of the procedure, multiple lobes should be biopsied and more samples taken.
Margaret A Kypreos, Kim C Styrvoky, Steven Wu, Audra Schwalk, Traci N Adams. Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease.. PloS one. 2026; doi:10.1371/journal.pone.0354460.
Margaret A Kypreos, Kim C Styrvoky, Steven Wu, Audra Schwalk, Traci N Adams (2026). Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease.. PloS one. https://doi.org/10.1371/journal.pone.0354460
Margaret A Kypreos, Kim C Styrvoky, Steven Wu, Audra Schwalk, Traci N Adams. Diagnostic yield and complication rate of transbronchial lung cryobiopsy using 1.1 mm probe in patients with interstitial lung disease.[J]. PloS one, 2026 doi:10.1371/journal.pone.0354460.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出