数字医学成像是有效医学诊断的基础,目前属于一个动态发展的科学领域。光学相干断层扫描(OCT)能够对组织进行实时原位成像,无需进行活检、组织学操作或X射线检查。Pirop® Echo-son设备通过超声测量组织。本横断面初步研究旨在通过评估将OCT与超声联合应用于牙周诊断和临床实践以评估成年患者健康牙龈水平黏膜厚度的可能性,提出一种新的牙龈组织分析方法。采用生物测量超声扫描仪和3D-OCT相机对13名患者进行了检查。对所得结果进行了比较和分析。年龄组间或性别间的比较分别采用Kruskal-Wallis方差分析(ANOVA)和Mann-Whitney U检验。对Pirop®与OCT参数之间进行了相关性分析,并按年龄组和性别进行分组。平均牙龈厚度(GT)为1.31 mm,平均上皮厚度为0.33 mm。上皮厚度与总GT之间无统计学显著相关性。牙龈和上皮厚度不依赖于年龄或性别。由于样本量有限,本初步研究提供的是探索性、描述性发现,需要在更大规模、具有足够检验效能的研究中加以证实。各项比较均未达到统计学显著性(所有p > 0.05);效应量大小不一且不精确。光学相干断层扫描成像可通过提供上皮厚度信息来补充总GT的超声测量。该联合方法有待验证,作为供区评估和牙周手术规划的潜在辅助手段。

Abstract

Digital medical imaging is the basis for effective medical diagnostics and is currently part of a dynamically developing field of science. Optical coherence tomography (OCT) allows for in situ imaging of tissues in real time, without the need to perform biopsies, histological procedures, or X-rays. Pirop® Echo-son device measures the tissue ultrasonographically. The aim of this cross-sectional pilot study was to propose a new method of gingival tissue analysis by evaluating the possibility of using OCT and echo-son jointly in periodontal diagnostics and clinical practice for assessing the horizontal mucosal thickness of healthy gingiva in adult patients. Thirteen patients were examined using a biometric ultrasound scanner and 3D-OCT camera. The obtained results were compared and analyzed. Comparisons between age groups or sex were made with Kruskal-Wallis analysis of variance (ANOVA) and Mann-Whitney U tests, respectively. A correlation analysis was performed between Pirop® and OCT parameters, also divided into age groups and sex. The mean gingival thickness (GT) was 1.31 mm and the mean epithelial thickness was 0.33 mm. There was no statistically significant correlation between epithelial thickness and total GT. The thickness of the gingiva and epithelium did not depend on age or sex. Due to the limited sample size, this pilot study provides exploratory, descriptive findings that warrant confirmation in a larger, adequately powered study. No comparison reached statistical significance (all p > 0.05); effect sizes varied in magnitude and were imprecise. Optical coherence tomography imaging may complement ultrasonographic measurement of total GT by providing information on epithelial thickness. The combined approach warrants validation as a potential aid for donor-site assessment and periodontal surgery planning.

如何引用

AMA

Nanxi Tao, Renata Samulak, Łukasz Wilczyński, Maciej Mularczyk, Mariusz Suwała, Joanna Hetmańska-Kołacz, et al. Optical coherence tomography and biometric ultrasound for gingival phenotype and epithelial thickness assessment: A cross-sectional pilot study.. Advances in clinical and experimental medicine : official organ Wroclaw Medical University. 2026; doi:10.17219/acem/210586.

APA

Nanxi Tao, Renata Samulak, Łukasz Wilczyński, Maciej Mularczyk, Mariusz Suwała, Joanna Hetmańska-Kołacz, et al (2026). Optical coherence tomography and biometric ultrasound for gingival phenotype and epithelial thickness assessment: A cross-sectional pilot study.. Advances in clinical and experimental medicine : official organ Wroclaw Medical University. https://doi.org/10.17219/acem/210586

GB/T 7714

Nanxi Tao, Renata Samulak, Łukasz Wilczyński, Maciej Mularczyk, Mariusz Suwała, Joanna Hetmańska-Kołacz, et al. Optical coherence tomography and biometric ultrasound for gingival phenotype and epithelial thickness assessment: A cross-sectional pilot study.[J]. Advances in clinical and experimental medicine : official organ Wroclaw Medical University, 2026 doi:10.17219/acem/210586.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Advances in clinical and experimental medicine : official organ Wroclaw Medical University 的其他文献