基于解剖结构的耳蜗植入接受者匹配
Anatomy-based fitting for cochlear implant recipients.
Anatomy-based fitting for cochlear implant recipients.
频率-位置失配是指人工耳蜗电极所传递的频率信息与所刺激的耳蜗自然位置频率位置之间的差异。已有研究表明,频率-位置失配对人工耳蜗的使用效果产生负面影响。基于解剖的调机(anatomy-based fitting, ABF)将滤波频率与耳蜗频率位置对齐,以最小化或消除频率-位置失配。本文综述了关于电极阵列植入位置变异性的现有证据、频率-位置失配对人工耳蜗使用者效果的影响,以及ABF流程的有效性。大多数ABF流程通过影像学确定电极触点的角度植入深度,计算耳蜗位置频率,然后调整每个电极触点的滤波频率以匹配耳蜗位置频率。尽管各ABF流程的具体方法有所不同,但研究普遍报告,与默认调机图相比,ABF在噪声下言语识别、音乐感知、使用者满意度和/或音质方面有所改善。目前尚不明确的是默认调机与ABF流程之间的长期效果差异、在确定耳蜗位置时是否存在首选的频率-位置函数,以及对于人工耳蜗和电声刺激装置使用者是否存在最优的ABF流程。人工耳蜗使用者使用ABF调机图聆听的早期证据显示,与默认设置调机图相比效果更好。
Frequency-to-place mismatch is the discrepancy between the frequency information delivered by a cochlear implant electrode and the natural cochlear place frequency location that is stimulated. Frequency-to-place mismatch has been shown to negatively influence cochlear implant outcomes. Anatomy-based fitting (ABF) aligns filter frequencies with cochlear frequency place to minimize or eliminate frequency-to-place mismatches. This article reviews the current evidence on variability in electrode array placement, influence of frequency-to-place mismatches on cochlear implant recipient outcomes, and effectiveness of ABF procedures. Most ABF procedures identify the angular insertion depth of the electrode contacts using imaging, calculate the cochlear place frequency, and then adjust filter frequencies for each electrode contact to match the cochlear place frequencies. While the specific approach varies across ABF procedures, studies generally report improvements in speech recognition in noise, music perception, user satisfaction, and/or sound quality as compared to default maps. What remains unclear are the long-term outcomes between default and ABF procedures, if there is a preferred frequency-to-place function when determining cochlear place, and whether there is an optimal ABF procedure for cochlear implant and electric-acoustic stimulation device users. Early evidence of cochlear implant recipients listening with ABF maps demonstrates better results compared to maps with default settings.
Saangyoung E Lee, Margaret T Dillon, Kevin D Brown. Anatomy-based fitting for cochlear implant recipients.. Current opinion in otolaryngology & head and neck surgery. 2026; doi:10.1097/MOO.0000000000001146.
Saangyoung E Lee, Margaret T Dillon, Kevin D Brown (2026). Anatomy-based fitting for cochlear implant recipients.. Current opinion in otolaryngology & head and neck surgery. https://doi.org/10.1097/MOO.0000000000001146
Saangyoung E Lee, Margaret T Dillon, Kevin D Brown. Anatomy-based fitting for cochlear implant recipients.[J]. Current opinion in otolaryngology & head and neck surgery, 2026 doi:10.1097/MOO.0000000000001146.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出