活体肝移植后胆道吻合口狭窄的塑料、全覆盖金属和导管内金属支架的比较:单中心经验

Comparison of Plastic, Fully Covered Metal, and Intraductal Metal Stents for Biliary Anastomotic Strictures After Living Donor Liver Transplantation: A Single-Center Experience.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

良性胆道吻合口狭窄(BAS)仍是活体肝移植(LDLT)术后最常见的并发症之一。尽管多根塑料支架(MPS)传统上被视为标准内镜治疗方案,但全覆膜自膨式金属支架(FCSEMS)和胆管内全覆膜自膨式金属支架(ID-FCSEMS)已成为替代策略。本研究旨在比较MPS、FCSEMS和ID-FCSEMS在治疗移植后胆道吻合口狭窄中的疗效与安全性。本回顾性单中心队列研究纳入2020年1月至2025年1月期间在LDLT后发生良性胆道吻合口狭窄并接受基于ERCP治疗的连续成年患者。患者根据初始支架策略分为:MPS组(=32)、FCSEMS组(=30)和ID-FCSEMS组(=25)。主要结局为总体治疗成功。次要结局包括复发、ERCP次数、治疗持续时间、术后住院、支架移位及操作相关不良事件。共纳入87例患者。MPS组、FCSEMS组和ID-FCSEMS组的临床成功率分别为81.3%、83.3%和92.0%(=0.501)。复发率分别为18.8%、10.0%和12.0%(=0.579)。金属支架组所需ERCP次数显著少于MPS组(中位数5 vs. 2 vs. 2;<0.001)。FCSEMS组和ID-FCSEMS组的中位治疗持续时间显著短于MPS组(12 vs. 10 vs. 9个月;<0.001)。金属支架组的术后住院时间也缩短(7 vs. 4 vs. 3天;<0.001)。包括胆管炎、胰腺炎、出血、穿孔和死亡率在内的不良事件发生率在各组间相当。支架移位发生率在MPS组为21.9%,FCSEMS组为23.3%,ID-FCSEMS组为12.0%(=0.525)。多因素分析显示,MELD评分是治疗成功的唯一独立预测因素(校正OR 0.90,95%CI 0.83-0.98;=0.012)。在LDLT后胆道吻合口狭窄的治疗中,MPS、FCSEMS和ID-FCSEMS在狭窄解除率、复发率和不良事件方面达到相当的水平。然而,与常规塑料支架相比,FCSEMS和ID-FCSEMS显著减少了ERCP操作次数、治疗持续时间和住院时间。在评估的策略中,ID-FCSEMS表现出最高的数值成功率和最低的移位率,提示其在保持相当安全性和疗效的同时具有潜在的操作优势。

Abstract

: Benign biliary anastomotic strictures (BAS) remain among the most frequent complications after living donor liver transplantation (LDLT). Although multiple plastic stents (MPS) have traditionally been considered the standard endoscopic treatment, fully covered self-expandable metal stents (FCSEMS) and intraductal fully covered self-expandable metal stents (ID-FCSEMS) have emerged as alternative strategies. This study aimed to compare the efficacy and safety of MPS, FCSEMS, and ID-FCSEMS in the management of post-transplant biliary anastomotic strictures. : This retrospective single-center cohort study included consecutive adult patients who developed benign biliary anastomotic strictures after LDLT and underwent ERCP-based treatment between January 2020 and January 2025. Patients were categorized according to the initial stent strategy: MPS ( = 32), FCSEMS ( = 30), and ID-FCSEMS ( = 25). Primary outcome was overall treatment success. Secondary outcomes included recurrence, number of ERCP sessions, treatment duration, post-procedural hospitalization, stent migration, and procedure-related adverse events. : A total of 87 patients were included. Clinical success was achieved in 81.3% of patients treated with MPS, 83.3% treated with FCSEMS, and 92.0% treated with ID-FCSEMS ( = 0.501). Recurrence rates were 18.8%, 10.0%, and 12.0%, respectively ( = 0.579). Patients treated with metal stents required significantly fewer ERCP sessions than those treated with MPS (median 5 vs. 2 vs. 2; < 0.001). Median treatment duration was significantly shorter in the FCSEMS and ID-FCSEMS groups compared with the MPS group (12 vs. 10 vs. 9 months; < 0.001). Post-procedural hospitalization was also reduced with metal stents (7 vs. 4 vs. 3 days; < 0.001). Adverse event rates, including cholangitis, pancreatitis, bleeding, perforation, and mortality, were comparable among groups. Stent migration occurred in 21.9% of MPS patients, 23.3% of FCSEMS patients, and 12.0% of ID-FCSEMS patients ( = 0.525). On multivariable analysis, MELD score was the only independent predictor of treatment success (adjusted OR 0.90, 95% CI 0.83-0.98; = 0.012). : MPS, FCSEMS, and ID-FCSEMS achieved comparable rates of stricture resolution, recurrence, and adverse events in the treatment of biliary anastomotic strictures after LDLT. However, FCSEMS and ID-FCSEMS significantly reduced the number of ERCP procedures, treatment duration, and hospitalization compared with conventional plastic stenting. Among the evaluated strategies, ID-FCSEMS demonstrated the highest numerical success rate and lowest migration rate, suggesting a potential procedural advantage while maintaining comparable safety and efficacy.

如何引用

AMA

Ömer Küçükdemirci, Berk Baş. Comparison of Plastic, Fully Covered Metal, and Intraductal Metal Stents for Biliary Anastomotic Strictures After Living Donor Liver Transplantation: A Single-Center Experience.. Journal of clinical medicine. 2026; doi:10.3390/jcm15145641.

APA

Ömer Küçükdemirci, Berk Baş (2026). Comparison of Plastic, Fully Covered Metal, and Intraductal Metal Stents for Biliary Anastomotic Strictures After Living Donor Liver Transplantation: A Single-Center Experience.. Journal of clinical medicine. https://doi.org/10.3390/jcm15145641

GB/T 7714

Ömer Küçükdemirci, Berk Baş. Comparison of Plastic, Fully Covered Metal, and Intraductal Metal Stents for Biliary Anastomotic Strictures After Living Donor Liver Transplantation: A Single-Center Experience.[J]. Journal of clinical medicine, 2026 doi:10.3390/jcm15145641.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of clinical medicine 的其他文献