早期回顾性经验报告了非骨水泥模块化骨干假体在复杂翻修反向全肩关节成形术中的短期疗效

Early retrospective experience reporting short-term outcomes of a cementless modular diaphyseal stem in complex revision reverse total shoulder arthroplasty.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

非骨水泥模块化骨干压配柄(MDS)的发展为广泛肱骨骨缺损中的传统骨水泥固定提供了替代方案,在早期随访中实现了稳定性并减少了与骨水泥相关的并发症。评估使用非骨水泥压配MDS进行翻修反式全肩关节置换术(rTSA)的临床和影像学结果。评估术后早期生存率及该固定策略在复杂翻修病例中的有效性。回顾性研究(2023年1月至2024年5月),纳入14例使用MDS进行翻修rTSA且随访至少24个月的肩关节。功能结果采用Constant、ASES、ADLEIR、VAS和SST评分及活动范围(ROM)进行评估。影像学评估确定固定稳定性和松动情况。平均随访时间为30.1个月。手术指征包括感染(n=8)、假体周围骨折(n=5)和半肩关节置换术失败(n=1)。术后ROM改善,平均前屈上举114.6°,外展95.7°,外旋25.4°。功能评分亦提高(Constant:36.6→55.9;ASES:31.4→61;VAS:7.9→2.8)。未记录到假体松动、不稳定或术后骨折。2例急性感染经成功治疗无需翻修,1例无症状非创伤性肱骨柄脱位。非骨水泥模块化骨干压配柄在复杂翻修rTSA中显示出令人满意的早期临床和影像学结果,当近端干骺端固定无法实现时可能是一种有价值的选择。需要更大样本量和更长随访时间的研究来确认其长期耐久性和性能。

Abstract

Cementless modular diaphyseal press-fi t stems (MDS) development has provided an alternative to traditional cemented fixation in extensive humeral bone loss, achieving stability and reducing cement-related complications in early follow-up. To evaluate clinical and radiographic outcomes of revision rTSA using the cementless press-fit MDS. Assess early postoperative survival and the effectiveness of this fixation strategy in complex revision cases. Retrospective study (January2023-May2024), including 14 shoulders undergoing revision rTSA using MDS and a minimum 24-month follow-up. Functional outcomes were assessed using Constant, ASES, ADLEIR, VAS, and SST scores, and range of movement (ROM). Radiographic assessments determined fixation stability and loosening. Mean follow-up was 30.1 months. Indications for surgery included infection (n=8), periprosthetic fracture (n=5), and failed hemiarthroplasty (n=1). Postoperative ROM improved, with mean forward elevation of 114.6°, abduction of 95.7°, and external rotation of 25.4°. Functional scores also increased (Constant: 36.6→55.9; ASES: 31.4→61; VAS: 7.9→2.8). No implant loosening, instability, or postoperative fractures were recorded. Two acute infections, successfully treated without revision and one asymptomatic non-traumatic humeral stem disengagement. Cementless modular diaphyseal press-fi t stems demonstrated satisfactory early clinical and radiographic outcomes in complex revision rTSA and may represent a valuable option when proximal metaphyseal fixation cannot be achieved. Further studies with larger cohorts and longer follow-up are required to confirm their long-term durability and performance.

如何引用

AMA

Emilio Calvo, Maria Valencia, Cristina Delgado, Natalia Martinez-Catalan, Gonzalo Luengo-Alonso. Early retrospective experience reporting short-term outcomes of a cementless modular diaphyseal stem in complex revision reverse total shoulder arthroplasty.. International orthopaedics. 2026; doi:10.1007/s00264-026-06925-w.

APA

Emilio Calvo, Maria Valencia, Cristina Delgado, Natalia Martinez-Catalan, Gonzalo Luengo-Alonso (2026). Early retrospective experience reporting short-term outcomes of a cementless modular diaphyseal stem in complex revision reverse total shoulder arthroplasty.. International orthopaedics. https://doi.org/10.1007/s00264-026-06925-w

GB/T 7714

Emilio Calvo, Maria Valencia, Cristina Delgado, Natalia Martinez-Catalan, Gonzalo Luengo-Alonso. Early retrospective experience reporting short-term outcomes of a cementless modular diaphyseal stem in complex revision reverse total shoulder arthroplasty.[J]. International orthopaedics, 2026 doi:10.1007/s00264-026-06925-w.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

International orthopaedics 的其他文献