腹部计算机断层扫描检查的碘对比剂剂量方案:系统综述与元分析

Iodinated Contrast Media Dose Protocols for Computed Tomography Investigations of the Abdomen: A Systematic Review and Meta-Analysis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

尽管存在多种碘对比剂(ICM)给药方案,但腹部CT中优化物理成像信号的共识策略仍然缺乏。本系统综述与荟萃分析评估了个体化给药方案的表现,特别关注技术信号优化、临床安全性、潜在的材料节约及环境可持续性。检索了电子数据库(Cochrane、Embase、Medline)截至2026年1月的文献。对23项研究(11,680名参与者)进行了系统综合,比较了基于去脂体重(LBW)、总体重(TBW)、固定容积(FV)及软件辅助给药的方案。荟萃分析评估了容积优化和肝脏强化,并通过GRADE框架评价证据确定性。与FV方案相比,基于TBW的给药显著减少了对比剂容积,减少量为-8.74 mL(= 0.02),而LBW组相较TBW组减少-4.04 mL,表现为非显著趋势(= 0.11);然而,敏感性分析显示存在显著效应(-5.41 mL,95% [CI:-10.43,-0.39];= 0.03)。汇总肝脏强化结果显示,LBW与TBW相比(-1.36 HU,= 0.43)或FV与TBW相比(-2.74 HU,= 0.13)均无统计学显著差异。个体化ICM给药,尤其是基于LBW的方案,可能通过减少人群层面的碘负荷,为临床放射学实现更绿色和材料节约提供基础性策略。尽管个体容积减少幅度有限,这些方案可能有助于实现标准化的成像强化,但仍需更高质量的随机试验来确认其安全性和经济效益。

Abstract

While several dosing protocols for iodinated contrast media (ICM) exist, a consensus strategy for optimising the physical imaging signal in abdominal CT is lacking. This systematic review and meta-analysis evaluated the performance of individualised dosing protocols, specifically focusing on technical signal optimisation, clinical safety, potential material savings, and environmental sustainability. Electronic databases (Cochrane, Embase, Medline) were searched up to January 2026. Systematic synthesis of 23 studies (11,680 participants) compared protocols based on lean body weight (LBW), total body weight (TBW), fixed volume (FV) and software-assisted dosing. Meta-analyses assessed volume optimisation and hepatic enhancement, with evidence certainty evaluated via the GRADE framework. TBW-based dosing significantly reduced contrast volume by -8.74 mL compared to FV protocols ( = 0.02), while the -4.04 mL reduction in LBW versus TBW groups represented a non-significant trend ( = 0.11); however, a sensitivity analysis revealed a significant effect (-5.41 mL, 95% [CI: -10.43, -0.39]; = 0.03). Pooled hepatic enhancement showed no statistically significant differences for LBW vs. TBW (-1.36 HU, = 0.43) or FV vs. TBW (-2.74 HU, = 0.13). Individualised ICM dosing, particularly LBW-based, may potentially offer a foundational strategy for greener and material savings in clinical radiology by minimising population-level iodine load. Despite modest individual volume reductions, these protocols may potentially facilitate standardised imaging enhancement, though higher-quality randomised trials are required to confirm safety and economic benefits.

如何引用

AMA

Evans Ohemeng, Andrew Donkor, Ijeoma Chinedum Anyitey-Kokor, Obed Kojo Otoo, Theophilus N Akudjedu, William Kwadwo Antwi, et al. Iodinated Contrast Media Dose Protocols for Computed Tomography Investigations of the Abdomen: A Systematic Review and Meta-Analysis.. Journal of imaging. 2026; doi:10.3390/jimaging12070301.

APA

Evans Ohemeng, Andrew Donkor, Ijeoma Chinedum Anyitey-Kokor, Obed Kojo Otoo, Theophilus N Akudjedu, William Kwadwo Antwi, et al (2026). Iodinated Contrast Media Dose Protocols for Computed Tomography Investigations of the Abdomen: A Systematic Review and Meta-Analysis.. Journal of imaging. https://doi.org/10.3390/jimaging12070301

GB/T 7714

Evans Ohemeng, Andrew Donkor, Ijeoma Chinedum Anyitey-Kokor, Obed Kojo Otoo, Theophilus N Akudjedu, William Kwadwo Antwi, et al. Iodinated Contrast Media Dose Protocols for Computed Tomography Investigations of the Abdomen: A Systematic Review and Meta-Analysis.[J]. Journal of imaging, 2026 doi:10.3390/jimaging12070301.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of imaging 的其他文献