开发了一种液相色谱-串联质谱联用方法,用于定量人血浆中的精氨酸加压素
Development of a liquid chromatography coupled to tandem mass spectrometry method for the quantification of Arginine Vasopressin in human plasma.
Development of a liquid chromatography coupled to tandem mass spectrometry method for the quantification of Arginine Vasopressin in human plasma.
精氨酸加压素(AVP)是一种在下丘脑合成、由神经垂体释放的九肽。它在水和电解质稳态、尿液浓缩及血压调节中发挥核心作用。AVP分泌失调与多种病理状态相关,包括中枢性尿崩症和抗利尿激素分泌不当综合征。目前,AVP的定量主要依赖免疫测定法,但此类方法存在交叉反应、灵敏度有限及样本处理复杂等局限性。鉴于人血浆中AVP的内源性浓度极低(处于低ng/L范围),我们开发并验证了一种高灵敏度的液相色谱-串联质谱(LC-MS/MS)方法用于血浆AVP定量。样品经Oasis WCX固相萃取后行LC-MS/MS分析。采用含0.1%牛血清白蛋白(BSA)的磷酸盐缓冲液(PBS)作为替代基质用于校准品和验证样品,以避免内源性干扰。方法验证依照美国临床实验室标准化协会(CLSI)指南进行。精密度、准确度和测量不确定度采用单嵌套方差分析和e.noval软件进行评估。同时考察了全血和血浆样品中的稳定性。该方法在0.2 ng/L至60 ng/L的浓度范围内得到验证,精密度(变异系数)低于10%,准确度范围为96%至109%,测量不确定度低于15%,定量下限为0.2 ng/L。EDTA抗凝全血样品在室温下离心前可稳定长达3小时。总之,我们开发并验证了一种用于血浆AVP定量的高灵敏度LC-MS/MS方法。我们的新方法学非常适合临床应用。
Arginine Vasopressin (AVP) is a nonapeptide synthesized in the hypothalamus and released by the neurohypophysis. It plays a central role in water and electrolyte homeostasis, urine concentration and blood pressure regulation. Dysregulation of AVP secretion is associated with several pathological conditions, including central diabetes insipidus and syndrome of inappropriate antidiuretic hormone secretion. Currently, AVP quantification mainly relies on immunoassays which suffers from limitations such as cross reactivity, limited sensitivity and complex sample handling. Given the very low endogenous concentrations of AVP in human plasma (low ng/L range), a highly sensitive LC-MS/MS method was developed and validated for plasma AVP quantification. AVP was extracted using Oasis WCX solid-phase extraction prior to LC-MS/MS analysis. PBS containing 0.1% BSA was used as surrogate matrix for calibration and validation samples to avoid endogenous interferences. Method validation was performed according to the Clinical Laboratory Standards Institute guidelines. Precision, accuracy, and measurement uncertainty were evaluated using single-nested analysis of variation and e.noval software. Stability in whole blood and plasma samples was also investigated. The method was validated over a concentration range from 0.2 ng/L to 60 ng/L, with precision (coefficient of variation) below 10%, accuracy ranging from 96% and 109%, measurement uncertainty below 15%, and a lower limit of quantification of 0.2 ng/L. EDTA blood samples remained stable up to 3 h at room temperature before centrifugation. In conclusion, we have developed and validated a highly sensitive LC-MS/MS method for the quantification of AVP in plasma. Our novel methodology is well-suited for clinical applications.
E Grifnée, E Cavalier, C Le Goff. Development of a liquid chromatography coupled to tandem mass spectrometry method for the quantification of Arginine Vasopressin in human plasma.. Clinica chimica acta; international journal of clinical chemistry. 2026; doi:10.1016/j.cca.2026.121247.
E Grifnée, E Cavalier, C Le Goff (2026). Development of a liquid chromatography coupled to tandem mass spectrometry method for the quantification of Arginine Vasopressin in human plasma.. Clinica chimica acta; international journal of clinical chemistry. https://doi.org/10.1016/j.cca.2026.121247
E Grifnée, E Cavalier, C Le Goff. Development of a liquid chromatography coupled to tandem mass spectrometry method for the quantification of Arginine Vasopressin in human plasma.[J]. Clinica chimica acta; international journal of clinical chemistry, 2026 doi:10.1016/j.cca.2026.121247.