在暴露于视觉闪烁刺激期间基于眼睛参数预测眼睛疲劳和运动病
Prediction of eyestrain and motion sickness based on eye parameters during exposure to a visual flicker stimulus.
Prediction of eyestrain and motion sickness based on eye parameters during exposure to a visual flicker stimulus.
本研究探讨运动刺激及其引发的眼动在晕动症发生中的作用。面对具有挑战性的视觉刺激时,眼动参数能否可靠地预测视觉诱发晕动症(VIMS)?我们使用眼动仪并评估主观眼疲劳,以考察这些参数如何随抽象时空闪烁刺激的特定特征而变化,以及它们是否能预测VIMS。二十四名参与者观看了呈现在桌面显示器上的各种闪烁条件,这些条件在频率、空间刺激偏移和运动可预测性方面有所不同。我们使用改良版快速晕动症量表(FMS-Oculomotor)记录VIMS和眼疲劳的实时自我报告。较高的闪烁频率增加了VIMS和眼疲劳,而较大的空间偏移增加了VIMS但未增加眼疲劳。我们对眼动参数应用线性混合效应模型来预测自我报告的症状严重程度。这些模型解释了所报告的VIMS和眼疲劳评分变异的69%-76%。眼动参数预测VIMS的能力各不相同:注视持续时间和扫视次数在所有条件下均具有预测能力,而瞳孔直径和注视次数仅在刺激运动不可预测时具有信息价值。这些发现凸显了眼动参数作为VIMS和眼疲劳预测指标的潜力。我们讨论了对用户界面设计的启示。我们的发现强调,用于VIMS检测的眼动追踪应用必须考虑刺激特异性校准和个体基线,才能在不同视觉环境中实现最佳预测准确性。
This study investigates moving stimuli and the ensuing eye-movements in the genesis of motion sickness. When confronted with challenging visual stimulation, can oculomotor parameters reliably predict visually induced motion sickness (VIMS)? We used an eye-tracker and assessed subjective eyestrain to examine how these parameters vary as a function of specific characteristics of an abstract spatiotemporal flicker stimulus and whether they predict VIMS. Twenty-four participants viewed various flicker conditions presented on a desktop monitor, differing in frequency, spatial stimulus offset, and movement predictability. We recorded real-time self-reports of VIMS and eyestrain using a modified version of the Fast Motion Sickness Scale (FMS-Oculomotor). Higher flicker frequencies increased VIMS and eyestrain, whereas larger spatial offsets increased VIMS but not eyestrain. We applied linear mixed-effects models to the eye parameters to predict self-reported symptom severity. The models accounted for 69%-76% of variance in reported VIMS and eyestrain scores. Eye parameters varied in their ability to predict VIMS: fixation duration and number of saccades had predictive power in all conditions, whereas pupil diameter and number of fixations were only informative when stimulus motion was unpredictable. These findings highlight the potential of eye parameters as predictors of VIMS and eyestrain. We discuss implications for user interface design. Our findings emphasize that eye-tracking applications for VIMS detection must account for stimulus-specific calibration and individual baselines to achieve optimal predictive accuracy across varying visual environments.
Henrik Eichhorn, Heiko Hecht, Marlene Wessels, Christoph von Castell. Prediction of eyestrain and motion sickness based on eye parameters during exposure to a visual flicker stimulus.. Acta psychologica. 2026; doi:10.1016/j.actpsy.2026.107480.
Henrik Eichhorn, Heiko Hecht, Marlene Wessels, Christoph von Castell (2026). Prediction of eyestrain and motion sickness based on eye parameters during exposure to a visual flicker stimulus.. Acta psychologica. https://doi.org/10.1016/j.actpsy.2026.107480
Henrik Eichhorn, Heiko Hecht, Marlene Wessels, Christoph von Castell. Prediction of eyestrain and motion sickness based on eye parameters during exposure to a visual flicker stimulus.[J]. Acta psychologica, 2026 doi:10.1016/j.actpsy.2026.107480.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出