{“_”:“用于非酶电化学糖检测的LaSrMnO钙钛矿修饰玻碳电极。”,“sub”:[“0.9”,“0.1”,“3”]}

{"_":"A LaSrMnO perovskite modified glassy carbon electrode for non-enzymatic electrochemical sugar detection.","sub":["0.9","0.1","3"]}

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

本研究成功合成了LaSrMnO钙钛矿(Pe)材料,并将其与壳聚糖(CS)和氧化石墨烯(GO)复合形成纳米复合材料,用于修饰玻碳电极,作为非酶电化学传感器应用于总糖检测。通过扫描电子显微镜(SEM)、X射线衍射(XRD)和红外光谱(IR)对Pe材料的形貌和晶体结构进行了表征。修饰后的Pe/CS/GO/GCE电极对葡萄糖、蔗糖和乳糖等多种糖类表现出高灵敏度,同时对罐装软饮料中常见的干扰物质(如柠檬酸、烟酰胺和柠檬酸钠)表现出优异的选择性。值得注意的是,采用循环伏安法(CV)研究了Pe/CS/GO/GCE对葡萄糖的活性,结果显示在5至14 mM浓度范围内呈线性响应,检出限(LOD)为0.381 mM。该电极已成功应用于5%葡萄糖注射液以及实际食品和饮料样品中的糖含量测定。

Abstract

In this study, LaSrMnO perovskite (Pe) material was successfully synthesized and subsequently integrated with chitosan (CS) and graphene oxide (GO) to form a nanocomposite, which was used to modify a glassy carbon electrode for application as a non-enzymatic electrochemical sensor for total sugar detection. The morphology and crystalline structure of the Pe material were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and infrared (IR) spectroscopy. The modified Pe/CS/GO/GCE electrode exhibited high sensitivity to various kinds of sugar, including glucose, sucrose, and lactose, while demonstrating excellent selectivity against common interfering substances present in canned soft drinks, such as citric acid, niacinamide, and sodium citrate. Notably, the activity of Pe/CS/GO/GCE toward glucose was studied using cyclic voltammetry (CV), showing a linear response over a concentration range from 5 to 14 mM, with a limit of detection (LOD) of 0.381 mM. The electrode was successfully applied to sugar determination in 5% intravenous glucose solution and in real food and beverage samples.

如何引用

AMA

Nguyen T Quynh, D Thu Le, P Vuong Nguyen, T T Huyen Tran, K Tuan Nguyen, Tran Thanh Tung, et al. {"_":"A LaSrMnO perovskite modified glassy carbon electrode for non-enzymatic electrochemical sugar detection.","sub":["0.9","0.1","3"]}. RSC advances. 2026; doi:10.1039/d6ra01187j.

APA

Nguyen T Quynh, D Thu Le, P Vuong Nguyen, T T Huyen Tran, K Tuan Nguyen, Tran Thanh Tung, et al (2026). {"_":"A LaSrMnO perovskite modified glassy carbon electrode for non-enzymatic electrochemical sugar detection.","sub":["0.9","0.1","3"]}. RSC advances. https://doi.org/10.1039/d6ra01187j

GB/T 7714

Nguyen T Quynh, D Thu Le, P Vuong Nguyen, T T Huyen Tran, K Tuan Nguyen, Tran Thanh Tung, et al. {"_":"A LaSrMnO perovskite modified glassy carbon electrode for non-enzymatic electrochemical sugar detection.","sub":["0.9","0.1","3"]}[J]. RSC advances, 2026 doi:10.1039/d6ra01187j.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

RSC advances 的其他文献