PETRA:一种用于上肢康复机器人的具有实时架构的基座外骨骼试验台
PETRA: a pedestal exoskeletal testbed with real-time architecture for upper limb rehabilitation robotics.
PETRA: a pedestal exoskeletal testbed with real-time architecture for upper limb rehabilitation robotics.
超过85%的脑卒中幸存者存在上肢运动功能障碍,然而康复机器人技术的可及性仍集中于高收入国家,其原因在于成本超过10,000美元且架构依赖外部计算机。这一经济壁垒限制了低收入和中等收入国家(LMICs)的研究人员开发和验证新的治疗策略的能力。本文介绍PETRA(Pedestal Exoskeletal Testbed with Real-time Architecture,基座式外骨骼实时架构测试平台),这是一个开源、3自由度运动学验证测试平台,采用PETG材料制造,用于上肢康复研究,每个关节成本低于25美元。PETRA采用固定基座配置,将机器人动力学与使用者的生物力学扰动解耦,为表征参数化摆线传动和确定性双核固件提供受控环境,且不依赖PC/ROS。超过300次试验的实验验证确认定位精度符合临床要求,同时确定聚合物摩擦是主要技术约束。通过提供低成本、可复制的方法学标准,PETRA促进了资源有限机构从概念设计向稳健辅助技术的转化。
More than 85% of stroke survivors present motor impairment in the upper limb, yet access to rehabilitation robotics remains concentrated in high-income countries due to costs exceeding 10,000 USD and architectures dependent on external computers. This economic barrier limits the ability of researchers in low- and middle-income countries (LMICs) to develop and validate new therapeutic strategies. This article presents PETRA (Pedestal Exoskeletal Testbed with Real-time Architecture), an open-source, 3-degree-of-freedom kinematic validation testbed manufactured in PETG for upper limb rehabilitation research at a cost under 25 USD per joint. PETRA adopts a fixed pedestal configuration that decouples the robot's dynamics from the user's biomechanical disturbances, providing a controlled environment for characterizing parametric cycloidal transmissions and deterministic dual-core firmware without PC/ROS dependency. Experimental validation with over 300 trials confirms positioning accuracies within clinical requirements while identifying polymer friction as the primary technical constraint. By providing a low-cost, replicable methodological standard, PETRA facilitates the transition from conceptual design to robust assistive technology in institutions with limited resources.
Andres Garcia, Kevin Fernández, Andres Nenger, Redhwan Algabri, Carlos Salazar, Jonathan Leon, et al. PETRA: a pedestal exoskeletal testbed with real-time architecture for upper limb rehabilitation robotics.. Frontiers in rehabilitation sciences. 2026; doi:10.3389/fresc.2026.1859475.
Andres Garcia, Kevin Fernández, Andres Nenger, Redhwan Algabri, Carlos Salazar, Jonathan Leon, et al (2026). PETRA: a pedestal exoskeletal testbed with real-time architecture for upper limb rehabilitation robotics.. Frontiers in rehabilitation sciences. https://doi.org/10.3389/fresc.2026.1859475
Andres Garcia, Kevin Fernández, Andres Nenger, Redhwan Algabri, Carlos Salazar, Jonathan Leon, et al. PETRA: a pedestal exoskeletal testbed with real-time architecture for upper limb rehabilitation robotics.[J]. Frontiers in rehabilitation sciences, 2026 doi:10.3389/fresc.2026.1859475.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出