宫颈癌图像引导自适应近距离放射治疗中的自动计划:对高容量中心患者工作流程的影响分析
Automated planning in image-guided adaptive brachytherapy for cervical cancer: Impact analysis on patient workflows in high-volume centers.
Automated planning in image-guided adaptive brachytherapy for cervical cancer: Impact analysis on patient workflows in high-volume centers.
图像引导自适应近距离放疗(IGABT)可改善局部晚期宫颈癌的预后,但其资源和时间投入较大,尤其是在治疗计划制定阶段。本研究评估了使用经验证模型(BiCycle)的自动化IGABT治疗计划对工作流程优化和计划效率提升的影响。本研究分析了2022年1月至2024年7月期间从机构1(印度)和机构2(荷兰)收集的IGABT计划数据。采用3D CT/MRI影像引导的腔内(IC)及腔内联合组织间插植(IC + IS)植入计划。在完成靶区和危及器官(OARs)勾画及施源器重建后,比较手动与自动计划在驻留时间优化和驻留时间调整(微调)方面的计划时间(分钟)。采用Mann-Whitney检验评估中位时间的差异。自动化近距离放疗计划所节省的时间以治疗容量增加的形式进行建模。共分析了两家机构的69份计划,包括30份自动计划和39份手动计划。驻留时间位置选择和优化的中位时间在自动计划中为4.59分钟(四分位距[IQR]:4.00-5.90),在手动计划中为21分钟(IQR:12.00-30.00)。治疗驻留时间调整的中位时间在自动计划中为5分钟(IQR:3.46-8.50),在手动计划中为15分钟(IQR:11.00-24.00)。在每日治疗多达四名患者的高容量中心,自动化每日可节省多达两小时,并将治疗容量提高25%。自动化IGABT治疗计划可显著缩短计划时间并提高效率。
Image-guided adaptive brachytherapy (IGABT) improves outcomes in locally advanced cervical cancer, but remains resource- and time-intensive, particularly during treatment planning. This study evaluated the impact of automated IGABT treatment planning using a validated model (BiCycle) on workflow optimization and improved planning efficiency. This study analyzed IGABT planning data collected from Institution 1 (India) and Institution 2 (the Netherlands) between January 2022 and July 2024. Intracavitary (IC) and intracavitary + interstitial (IC + IS) implants planned with 3D CT/MRI imaging were employed. Once the target and organs at risk (OARs) were delineated and the applicator was reconstructed, manual and automated planning times (in minutes) for dwell time optimization and dwell time adjustment (fine-tuning) were compared. Mann-Whitney test evaluated differences in median time. Time savings with automated brachytherapy planning were modelled as increased treatment capacity. Sixty-nine plans from both institutions were analyzed, consisting of 30 automated and 39 manual plans. The median time for dwell time position selection and optimization was 4.59 minutes (interquartile range [IQR]: 4.00-5.90) using automated planning, and 21 minutes (IQR: 12.00-30.00) using manual planning. The median time for treatment dwell time adjustment was 5 minutes (IQR: 3.46-8.50) using automated planning, and 15 minutes (IQR: 11.00-24.00) using manual planning. In high-volume centers treating up to four patients daily, automation could save as much as two hours daily and enhance treatment capacity by 25%. Automating IGABT treatment planning significantly reduces planning time and improve efficiency.
Varsha Hande, Linda Rossi, Henrike Westerveld, Lorne Luthart, Prachi Mittal, Subhajit Panda, et al. Automated planning in image-guided adaptive brachytherapy for cervical cancer: Impact analysis on patient workflows in high-volume centers.. Journal of contemporary brachytherapy. 2026; doi:10.5114/jcb.2026.163311.
Varsha Hande, Linda Rossi, Henrike Westerveld, Lorne Luthart, Prachi Mittal, Subhajit Panda, et al (2026). Automated planning in image-guided adaptive brachytherapy for cervical cancer: Impact analysis on patient workflows in high-volume centers.. Journal of contemporary brachytherapy. https://doi.org/10.5114/jcb.2026.163311
Varsha Hande, Linda Rossi, Henrike Westerveld, Lorne Luthart, Prachi Mittal, Subhajit Panda, et al. Automated planning in image-guided adaptive brachytherapy for cervical cancer: Impact analysis on patient workflows in high-volume centers.[J]. Journal of contemporary brachytherapy, 2026 doi:10.5114/jcb.2026.163311.