高危近距离放射治疗妇科癌症中基于患者特异性自适应环危及器官轮廓的研发

Development of a patient-specific adaptive ring for organ at risk contours in high-dose-rate brachytherapy gynecologic cancers.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

高剂量率(HDR)近距离放疗用于妇科癌症时,需要对每个分次重复勾画危及器官(OAR),这是一项耗时且易受变异影响的任务。本研究评估了使用患者特异性自适应环来简化OAR勾画,同时不损害剂量学准确性和患者安全。分析了来自25例既往接受治疗患者的50个HDR近距离放疗宫腔管和卵圆体(T&O)分次。研究了两种自适应环:一种基于从临床靶区(CTV)到50%等剂量线(IDL)的外放边界生成,另一种基于从CTV到75% IDL的外放边界生成,分别称为50% IDL和75% IDL自适应环。在这两个环内勾画膀胱、直肠、小肠和乙状结肠,并将基于这些新勾画的D值与由医师生成的全器官勾画的临床D值进行比较。使用全OAR勾画和每种环策略对10个分次测量了勾画时间。在临床相关剂量水平下,所有OAR基于环的勾画与全器官勾画之间的D值误差均小于3%。使用自适应环使勾画时间减少50-60%(< 0.001),其中75% IDL环由于环尺寸较小,时间减少最多。基于IDL的自适应环为HDR妇科近距离放疗中的OAR勾画提供了一种高效策略。使用自适应环限制OAR勾画可实现分次特异性适配,减少勾画工作量,并保持剂量学准确性。

Abstract

High-dose-rate (HDR) brachytherapy for gynecologic cancers requires repeated organ at risk (OAR) contouring for each fraction, which is a time-consuming task susceptible to variability. This study evaluated the use of patient-specific adaptive rings to streamline OAR contouring without compromising dosimetric accuracy and patient safety. Fifty HDR brachytherapy tandem and ovoid (T&O) fractions from twenty-five previously treated patients were analyzed. Two adaptive rings were investigated: one generated based on margins from clinical target volume (CTV) to 50% isodose line (IDL), and the other based on margins from CTV to 75% IDL, referred to as the 50% IDL and 75% IDL adaptive rings, respectively. Bladder, rectum, small bowel, and sigmoid were contoured within these two rings, and D values based on these new contours were compared with clinical D values from full-organ contours generated by physician. Contouring times were measured for 10 fractions using full OAR delineation and each ring strategy. Errors in D between ring-based and full-organ contours were less than 3% for all OARs at clinically relevant dose levels. Contouring time decreased by 50-60% using adaptive rings ( < 0.001), with the 75% IDL ring giving the largest reduction in time due to the smaller ring size. Adaptive IDL-based rings provide an efficient strategy for OAR contouring in HDR gynecologic brachytherapy. Using adaptive rings to limit OAR contouring allows for fraction-specific adaptation, reduces contouring workload, and maintains dosimetric accuracy.

如何引用

AMA

Sruthi Sivabhaskar, Yesenia Gonzalez, Paul Medin, Brian Hrycushko, Kevin Albuquerque, Zohaib Iqbal. Development of a patient-specific adaptive ring for organ at risk contours in high-dose-rate brachytherapy gynecologic cancers.. Journal of contemporary brachytherapy. 2026; doi:10.5114/jcb.2026.162464.

APA

Sruthi Sivabhaskar, Yesenia Gonzalez, Paul Medin, Brian Hrycushko, Kevin Albuquerque, Zohaib Iqbal (2026). Development of a patient-specific adaptive ring for organ at risk contours in high-dose-rate brachytherapy gynecologic cancers.. Journal of contemporary brachytherapy. https://doi.org/10.5114/jcb.2026.162464

GB/T 7714

Sruthi Sivabhaskar, Yesenia Gonzalez, Paul Medin, Brian Hrycushko, Kevin Albuquerque, Zohaib Iqbal. Development of a patient-specific adaptive ring for organ at risk contours in high-dose-rate brachytherapy gynecologic cancers.[J]. Journal of contemporary brachytherapy, 2026 doi:10.5114/jcb.2026.162464.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI