近距离放疗前MRI在辅助宫颈癌手术施源器选择中的价值
The value of pre-brachytherapy MRI in aiding applicator selection for cervical cancer procedures.
The value of pre-brachytherapy MRI in aiding applicator selection for cervical cancer procedures.
宫颈癌治疗中近距离放疗施源器的选择通常依赖于术中判断。近距离放疗前磁共振成像(pre-MRI)可针对不同阴道管(VC)解剖结构,为最适宜的施源器类型和尺寸提供更早期的指导。本研究探讨了pre-MRI阴道管体积与施源器选择之间的关系。共分析114例接受近距离放疗的宫颈癌患者(2022—2024年)。收集患者及治疗特征,包括施源器类型(宫腔管联合卵圆体[TO] vs. 宫腔管联合圆柱体加插植针[TC])。使用阴道凝胶行pre-MRI,以最佳勾画阴道管上1 cm和2 cm体积,随后分析其与施源器类型及尺寸选择的关系。大多数患者为FIGO III-IV期(75%)疾病。阴道管上2 cm体积在所有分次中均与施源器选择显著相关,体积较小者倾向于选择TC施源器,体积较大者倾向于选择TO施源器(< 0.01);TC组平均体积低于TO组(6.48 vs. 8.06 cm,= 0.045)。pre-MRI阴道管体积测量可能有助于施源器选择;尤其是上2 cm体积< 4 cm时可能需要TC施源器而非TO施源器。将这种体积指导方法纳入操作规划,可通过促进 upfront 施源器选择和定位来提高效率。这值得进一步研究,以确定对施源器选择进行分层是否能够优化与局部控制相关的近距离放疗剂量学和植入质量指标。
Brachytherapy applicator selection in the treatment of cervical cancer often relies on intra-operative judgment. Pre-brachytherapy magnetic resonance imaging (pre-MRI) may provide earlier guidance for most appropriate applicator type and size across varying vaginal canal (VC) anatomies. This study investigated the relationship between pre-MRI VC volumes and applicator selection. One hundred and fourteen patients with cervical cancer treated with brachytherapy (2022-2024) were analyzed. Patient and treatment characteristics, including applicator type (tandem and ovoid [TO] vs. tandem and cylinder with needles [TC]), were collected. Pre-MRI with vaginal gel was used for optimal delineation of the upper 1 cm and 2 cm VC volumes, which were then analyzed in relation to applicator type and size selection. Most patients had FIGO stage III-IV (75%) disease. The upper 2 cm VC volume was significantly associated with applicator selection across all fractions, with smaller volumes favoring TC applicators and larger volumes favoring TO applicators ( < 0.01); mean volumes were lower in the TC group than the TO group (6.48 vs. 8.06 cm, = 0.045). Pre-MRI VC volume measurements may aid in applicator selection; particularly upper 2 cm volumes < 4 cm may require TC applicators as opposed to TO applicators. Incorporating this volume-guided approach into procedural planning can improve efficiency by facilitating upfront applicator selection and positioning. This warrants further study to determine whether stratifying applicator selection could optimize brachytherapy dosimetry and implant quality metrics associated with local control.
Jennifer S Chiang, Abass M Conteh, Thomas Niedermayr, Elizabeth Kidd. The value of pre-brachytherapy MRI in aiding applicator selection for cervical cancer procedures.. Journal of contemporary brachytherapy. 2026; doi:10.5114/jcb.2026.163306.
Jennifer S Chiang, Abass M Conteh, Thomas Niedermayr, Elizabeth Kidd (2026). The value of pre-brachytherapy MRI in aiding applicator selection for cervical cancer procedures.. Journal of contemporary brachytherapy. https://doi.org/10.5114/jcb.2026.163306
Jennifer S Chiang, Abass M Conteh, Thomas Niedermayr, Elizabeth Kidd. The value of pre-brachytherapy MRI in aiding applicator selection for cervical cancer procedures.[J]. Journal of contemporary brachytherapy, 2026 doi:10.5114/jcb.2026.163306.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出