使用Contour装置进行囊内血流阻断:破裂颅内动脉瘤的单中心经验

Intrasaccular Flow Disruption with the Contour Device: A Single-Center Experience in Ruptured Intracranial Aneurysms.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

宽颈颅内动脉瘤的管理对临床医生而言仍是一项挑战。囊内装置如Contour和WEB(Woven Endo Bridge)装置为宽颈颅内动脉瘤的管理提供了新的希望。Contour神经血管系统由CERUS Endovascular(美国加利福尼亚州弗里蒙特)开发,是一种基于血流中断和血流导向原理工作的囊内装置。我们报告本机构在破裂颅内动脉瘤病例中使用该装置的经验。旨在探讨Contour装置作为破裂颅内动脉瘤一线干预手段的作用,重点关注其安全性、有效性及患者结局。这是一项在印度勒克瑙Dr. Ram Manohar Lohia医学科学研究所(RMLIMS)神经外科进行的回顾性研究。所有病例均由同一名外科医生手术。收集并分析了所有接受Contour装置治疗患者的临床、影像学及随访数据。在6周时使用改良Rankin量表(MRS)评估患者的功能状态。随访时行脑MR血管成像(MRA),采用Raymond-Roy闭塞分类(RROC)评估动脉瘤闭塞情况。在15例接受治疗的破裂颅内动脉瘤中,10例为前交通动脉(ACom)动脉瘤,3例为大脑中动脉(MCA)分叉部动脉瘤,2例为基底动脉尖动脉瘤。Contour装置在所有病例中均成功释放。在6个月随访时,MRA显示11例患者达到Raymond-Roy闭塞分类(RROC)I级闭塞,2例患者存在瘤颈残留(RROC II级),1例患者为RROC IIIa级闭塞伴动脉瘤部分再灌注。囊内血流中断是一种新型血管内治疗方法,使用Contour等装置治疗宽颈颅内动脉瘤。Contour装置表现出良好的安全性特征,并被证明是一种稳定且有效的治疗选择,即使在动脉瘤破裂的急性期亦是如此。

Abstract

Management of wide-necked intracranial aneurysms remains a challenge for clinicians. Intrasaccular devices like Contour and WEB (Woven Endo Bridge) devices offer new promise in managing wide-necked intracranial aneurysms. The Contour Neurovascular System, developed by CERUS Endovascular (Fremont, California, USA), is an intrasaccular device working on the principle of flow-disruption and flow diversion. We report our institutional experience with this device in cases of ruptured intracranial aneurysms. To investigate the role of the Contour device as a first-line intervention in ruptured intracranial aneurysms, focusing on its safety, efficacy, and patient outcomes. This is a retrospective study conducted in the Department of Neurosurgery at Dr. Ram Manohar Lohia Institute of Medical Sciences (RMLIMS), Lucknow, India. A single surgeon operated on all cases. Clinical, radiological, and follow-up data were collected and analyzed for all patients treated with the Contour device. Modified Rankin scale (MRS) was used at 6 weeks to assess the patient's performance. MR angiography (MRA) brain was done at follow-up to assess the aneurysmal occlusion using the Raymond-Roy classification (RROC). Of the 15 cases of treated ruptured intracranial aneurysms, 10 were anterior communicating artery (ACom) aneurysms, 3 were middle cerebral artery (MCA) bifurcation aneurysms, and 2 were basilar tip aneurysms. The contour device was successfully deployed in all the cases. At 6-month follow-up, MRA revealed that 11 patients had Raymond-Roy Occlusion Classification (RROC) Class I occlusion, 2 patients had neck remnants (RROC Class II), and 1 patient had RROC Class IIIa occlusion with partial aneurysmal reperfusion. Intrasaccular flow disruption is a novel endovascular approach for the treatment of wide necked intracranial aneurysms using devices like Contour. The Contour device demonstrated a favorable safety profile and proved to be a stable and effective treatment option, even in the acute setting of aneurysmal rupture.

如何引用

AMA

Deepak K Singh, Praveenkumar N Sangolli, Prevesh Sharma, Vipin Chand, Vineet K Mishra, Neha Singh. Intrasaccular Flow Disruption with the Contour Device: A Single-Center Experience in Ruptured Intracranial Aneurysms.. Neurology India. 2026; doi:10.4103/neurol-india.Neurol-India-D-25-00443.

APA

Deepak K Singh, Praveenkumar N Sangolli, Prevesh Sharma, Vipin Chand, Vineet K Mishra, Neha Singh (2026). Intrasaccular Flow Disruption with the Contour Device: A Single-Center Experience in Ruptured Intracranial Aneurysms.. Neurology India. https://doi.org/10.4103/neurol-india.Neurol-India-D-25-00443

GB/T 7714