在后向上位移的情况下,义齿附着系统对2-种植体覆盖义齿种植体周围骨应变和移位角度的影响
Effect of denture attachment systems on peri-implant bone strain and dislodgement angle in 2-implant-retained overdentures under posterior upward displacement.
Effect of denture attachment systems on peri-implant bone strain and dislodgement angle in 2-implant-retained overdentures under posterior upward displacement.
评估在2枚种植体支持的覆盖义齿中,不同义齿附着系统、种植体周围位点及固位力水平在3 mm后侧向上位移下产生的应变,并评估脱位角度。测试了四个附着体组(LOCATOR标准范围插件(LOC)、LOCATOR扩展范围插件(LOE)、LOCATOR R-Tx标准范围插件(LOR)和Novaloc(NOV)),每组设三个固位力水平。在模拟后侧向上位移直至插件完全脱位的过程中记录种植体周围应变,并测量脱位角度。应变数据采用三因素混合方差分析,脱位角度采用双因素方差分析(α = 0.05)。应变方面,附着系统与种植体周围位点之间存在显著交互作用(p < 0.001)。NOV组在各位点的应变值均显著高于其他组,而LOC、LOE和LOR组之间未见差异。各系统间,近中位点的应变值最高。脱位角度方面,附着系统(p < 0.001)和固位力水平(p = 0.002)的主效应显著。LOR组的脱位角度最大,其次为LOC、LOE和NOV组。高固位力导致的脱位角度显著低于中固位力(p = 0.002)和低固位力(p = 0.021),而中固位力与低固位力之间无差异(p = 1.00)。在后侧向上位移下,附着系统显著影响种植体周围应变和脱位角度。NOV附着体表现出最高的种植体周围应变,尤其是在近中位点。固位插件水平未显著影响种植体周围应变,但确实影响脱位角度。LOR附着体的脱位角度最大,而NOV附着体的脱位角度最小。
To evaluate strains generated by different denture attachment systems, peri-implant sites, and retention levels under 3-mm posterior upward displacement in 2-implant-retained overdentures and to evaluate dislodgement angles. Four attachment groups (LOCATOR with standard-range insert (LOC), LOCATOR with extended-range insert (LOE), LOCATOR R-Tx with standard-range insert (LOR), and Novaloc (NOV)), each with three retention levels, were tested. Peri-Implant strains were recorded during simulated posterior upward displacement until complete insert dislodgement. Dislodgement angles were also measured. Strain data were analyzed by three-way mixed ANOVA, and dislodgement angles were analyzed by two-way ANOVA (α = 0.05). A significant interaction between attachment system and peri-implant site was found for strain (p < 0.001). The NOV group exhibited significantly higher strain values than the other groups at each site, whereas no differences were observed among the LOC, LOE, and LOR groups. Across systems, the mesial site exhibited the highest strain values. For dislodgement angle, significant main effects were found for attachment system (p < 0.001) and retention level (p = 0.002). The LOR group exhibited the greatest dislodgement angle, followed by the LOC, LOE, and NOV groups. High retention resulted in significantly lower dislodgement angle than medium (p = 0.002) and low retention (p = 0.021), whereas there was no difference between medium and low retention (p = 1.00). Attachment system significantly affected peri-implant strain and dislodgement angle under posterior upward displacement. The NOV attachment exhibited the highest peri-implant strain, particularly at the mesial site. Retention insert level did not significantly affect the peri-implant strain but did affect dislodgement angle. The LOR attachment demonstrated the greatest dislodgement angle, whereas the NOV attachment showed the lowest dislodgement angle.
Sidarat Chinokul, Krid Kamonkhantikul, Woraporn Homsiang, Mansuang Arksornnukit. Effect of denture attachment systems on peri-implant bone strain and dislodgement angle in 2-implant-retained overdentures under posterior upward displacement.. Journal of prosthodontics : official journal of the American College of Prosthodontists. 2026; doi:10.1111/jopr.70207.
Sidarat Chinokul, Krid Kamonkhantikul, Woraporn Homsiang, Mansuang Arksornnukit (2026). Effect of denture attachment systems on peri-implant bone strain and dislodgement angle in 2-implant-retained overdentures under posterior upward displacement.. Journal of prosthodontics : official journal of the American College of Prosthodontists. https://doi.org/10.1111/jopr.70207
Sidarat Chinokul, Krid Kamonkhantikul, Woraporn Homsiang, Mansuang Arksornnukit. Effect of denture attachment systems on peri-implant bone strain and dislodgement angle in 2-implant-retained overdentures under posterior upward displacement.[J]. Journal of prosthodontics : official journal of the American College of Prosthodontists, 2026 doi:10.1111/jopr.70207.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出