微波功率循环对温度均匀性、微生物灭活和品质的影响:牛奶热加工的计算方法
Effect of Microwave Power Cycle on Temperature Uniformity, Microbial Inactivation, and Quality: Computational Approach for Milk Thermal Processing.
Effect of Microwave Power Cycle on Temperature Uniformity, Microbial Inactivation, and Quality: Computational Approach for Milk Thermal Processing.
微波功率控制通常通过磁控管的通断功率循环或基于逆变器的连续控制来实现所需功率。尽管以往研究主要关注功率循环对温度均匀性的影响,但其对微生物安全性和品质的影响仍认识不足。本研究在固定占空比(0.5)条件下,考察了不同通断功率循环配置对温度演变及微生物和酶灭活动力学的影响。为此,选择牛奶作为样品食品,并采用基于有限元的多物理场模型开展所需评估。结果表明,尽管样品的最终温度和吸收功率相同,不同功率循环设置导致显著不同的升温速率。虽然由于液体样品中触发的自然对流效应,温度均匀性未受到显著影响,但微生物灭活动力学差异显著。较长的导通持续时间导致快速升温 and 更高的灭活水平。除微生物灭活外,以γ-谷氨酰转移酶(GGT)灭活为代表的酶品质劣变也受到所施加功率循环的强烈影响,表明需要平衡微生物灭活与品质保持。这些结果表明,功率循环诱导的温度曲线在决定微波处理的安全性和品质结果中起关键作用。本研究进一步强调,在微波处理中明确报告功率循环设置以确保可重复性和可比性的必要性。实际应用:本研究表明,从温度依赖性效应的角度来看,相同的微波功率水平并不总是产生相同的结果,因为不同的功率循环设置会导致不同的温度历程。因此,尤其是在工业环境中,安全性和品质不能仅通过平均功率输入来控制。相反,必须仔细选择功率循环配置,并监测其对产品温度变化的影响。这些发现可能有助于设计微波工艺,以确保所需的微生物灭活,同时最大限度地减少品质损失。
Microwave power control is commonly achieved either by magnetrons` on-and-off power cycling or inverter-based continuous control to obtain the desired power. Although previous studies have focused on the effect of power cycling on temperature uniformity, its implications on microbial safety and quality remain insufficiently understood. In this study, the effect of different on-and-off power cycle configurations at a fixed duty cycle (0.5) on temperature evolution and microbial and enzymatic inactivation kinetics was investigated. For this purpose, milk was chosen as the sample food product, and the required evaluations were carried out using a finite element-based multiphysics model. The results showed that different power cycle settings led to significantly different temperature increase rates despite the identical final temperature and absorbed power by the sample. While temperature uniformity was not significantly affected due to the natural convection effects triggered in the liquid sample, microbial inactivation kinetics varied substantially. Longer on-cycle durations resulted in rapid temperature increases and higher inactivation levels. Besides the microbial inactivation, enzymatic quality degradation, represented by γ-glutamyl transferase (GGT) inactivation, was strongly influenced by the applied power cycles, indicating the requirement to balance the microbial inactivation with quality preservation. These results demonstrate that power cycle-induced temperature profiles play a critical role in determining safety and quality outcomes in microwave processing. This study further highlights the requirement of reporting power cycle settings explicitly in microwave processing to ensure repeatability and comparability. PRACTICAL APPLICATIONS: This study demonstrates that the same microwave power level does not always yield the same results in the view of temperature dependent effects since different power cycle settings lead to various temperature histories. Hence, especially in industrial settings, safety and quality cannot be controlled by average power inputs only. Instead, the power cycle configuration must be carefully selected and monitored with its effects on the temperature change of the product. These findings might assist in designing microwave processes to ensure required microbial inactivation while minimizing quality losses.
Ozan Karataş, Elif Nida Çakır, Ferruh Erdoğdu. Effect of Microwave Power Cycle on Temperature Uniformity, Microbial Inactivation, and Quality: Computational Approach for Milk Thermal Processing.. Journal of food science. 2026; doi:10.1111/1750-3841.71306.
Ozan Karataş, Elif Nida Çakır, Ferruh Erdoğdu (2026). Effect of Microwave Power Cycle on Temperature Uniformity, Microbial Inactivation, and Quality: Computational Approach for Milk Thermal Processing.. Journal of food science. https://doi.org/10.1111/1750-3841.71306
Ozan Karataş, Elif Nida Çakır, Ferruh Erdoğdu. Effect of Microwave Power Cycle on Temperature Uniformity, Microbial Inactivation, and Quality: Computational Approach for Milk Thermal Processing.[J]. Journal of food science, 2026 doi:10.1111/1750-3841.71306.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出