颈椎间盘置换术的当代理念:植入物设计、约束、并发症及技术要点
Contemporary Concepts in Cervical Disk Arthroplasty: Implant Design, Constraint, Complications, and Technical Pearls.
Contemporary Concepts in Cervical Disk Arthroplasty: Implant Design, Constraint, Complications, and Technical Pearls.
» 颈椎间盘置换术(CDA)是美国食品药品监督管理局(FDA)批准的运动保留型替代方案,用于单节段和双节段退行性椎间盘疾病,替代颈前路椎间盘切除融合术,有高级别证据支持,并与邻近节段退变减少及临床结局相当或改善相关。» FDA批准的CDA植入物在生物力学设计、自由度(DoF)和约束程度上存在差异,影响运动保留、节段控制和长期运动学。器械范围从约束型(3个自由度)到半约束型和粘弹性设计(4-6个自由度)。植入物的关节面活动和材料影响磨损、影像兼容性和生物力学行为,在器械选择时应予以考虑。» 基于约束程度的分类为CDA植入物选择提供了实用、以生物力学为依据的框架。约束程度应与患者病理相匹配。在节段性不稳、终板完整性受损或骨质量差的情况下,约束型植入物可能更可取。对于运动保留良好、小关节健康且功能需求高的患者,半约束型或粘弹性器械可能提供更好的结局。» 对失败模式的结构化理解对于安全有效地使用CDA至关重要。并发症和失败可能源于手术技术错误(如终板破坏、位置不良)、生物学反应(如骨溶解、异位骨化)或机械性并发症(如植入物断裂、下沉)。技术方面的考量有助于术者降低并发症风险。
» Cervical disk arthroplasty (CDA) is a Food and Drug Administration (FDA)-approved motion-preserving alternative to anterior cervical diskectomy and fusion for 1-level and 2-level degenerative disk diseases, supported by high-level evidence and associated with reduced adjacent segment degeneration and comparable or improved clinical outcomes. » FDA-approved CDA implants differ in biomechanical design, degrees of freedom (DoF), and constraint, affecting motion preservation, segmental control, and long-term kinematics. Devices range from constrained (3 DoF) to semiconstrained and viscoelastic designs (4-6 DoF). Implant articulation and materials impact wear, imaging compatibility, and biomechanical behavior and should be considered during device selection. » Constraint-based classification provides a practical, biomechanics-informed framework for CDA implant selection. Constraint level should be matched to patient pathology. Constrained implants may be preferable in cases of segmental instability, compromised endplate integrity, or poor bone quality. Semiconstrained or viscoelastic devices may offer better outcomes for patients with preserved motion, healthy facets, and high functional demands. » A structured understanding of failure modes is critical for safe and effective CDA use. Complications and failure can result from surgical technique errors (e.g., endplate violation, malposition), biologic response (e.g., osteolysis, heterotopic ossification), or mechanical complications (e.g., implant fracture, subsidence). Technical considerations aid the surgeon in reducing risk of complications.
Austin Q Nguyen, Andrei Demkov, Don Le, Rohan Vemu, Mark L Prasarn, Corey T Walker, et al. Contemporary Concepts in Cervical Disk Arthroplasty: Implant Design, Constraint, Complications, and Technical Pearls.. JBJS reviews. 2026; doi:10.2106/JBJS.RVW.26.00041.
Austin Q Nguyen, Andrei Demkov, Don Le, Rohan Vemu, Mark L Prasarn, Corey T Walker, et al (2026). Contemporary Concepts in Cervical Disk Arthroplasty: Implant Design, Constraint, Complications, and Technical Pearls.. JBJS reviews. https://doi.org/10.2106/JBJS.RVW.26.00041
Austin Q Nguyen, Andrei Demkov, Don Le, Rohan Vemu, Mark L Prasarn, Corey T Walker, et al. Contemporary Concepts in Cervical Disk Arthroplasty: Implant Design, Constraint, Complications, and Technical Pearls.[J]. JBJS reviews, 2026 doi:10.2106/JBJS.RVW.26.00041.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出