沿uMI Panorama GS PET/CT系统轴向视野对多种放射性核素的图像质量和部分容积效应的量化
Quantification of image quality and partial volume effect along the axial field-of-view of uMI Panorama GS PET/CT system for multiple radionuclides.
Quantification of image quality and partial volume effect along the axial field-of-view of uMI Panorama GS PET/CT system for multiple radionuclides.
全面了解每种放射性核素独特的物理衰变特性如何影响其图像质量表现,对于定制采集方案和确保最佳临床应用至关重要。理解对比度恢复系数(CRC)的空间依赖性,是进行稳健的定量图像分析和准确临床解读的前提,因为部分容积效应(PVE)和计数率沿轴向视野(AFOV)发生变化。在uMI Panorama GS PET/CT系统上使用多种放射性核素进行了图像质量评估,同时评估了其扩展AFOV范围内的CRC分布。遵循NEMA NU 2-2018标准,使用NEMA IEC(NEC)体模分别填充F、Cu、Ga、Zr、I和Y进行图像质量评估。测量CRC、背景变异性(BV)和肺部残余误差以量化图像质量。在AFOV的1/2、1/4、1/8和1/16四个轴向偏移位置依次测量CRC。通过比较使用和不使用PSF(点扩散函数)建模重建的PET图像,评估了放射性核素特异性PSF建模对CRC的影响。评估结果显示,F、Cu、Ga、Zr、I的图像质量相当,而Y表现出相似的CRC但更高的BV和更高的肺部残余误差,这归因于其较低的正电子分支比。BV和肺部残余误差随距AFOV中心轴向距离的增加而增大,而较大球体的CRC在各AFOV位置保持稳定;小球体CRC测量值因计数统计量减少而向周边区域表现出更大的离散度。PSF建模显著改善了Ga和I的CRC,这与其较长的正电子射程一致。所有研究的放射性核素在uMI Panorama GS PET/CT系统上均能有效成像。基于沿AFOV多个位置获得的CRC测量值,对AFOV均匀性进行了定量评估。
The comprehensive knowledge of how the distinct physical decay characteristics of each radionuclide shape their image quality performance is essential for tailoring acquisition protocols and ensuring optimal clinical applications. Understanding the spatial dependence of the contrast recovery coefficient (CRC) is a prerequisite for robust quantitative image analyses and accurate clinical interpretations, since the partial volume effect (PVE) and the count rate vary along the axial field of view (AFOV). Image quality assessments with various radionuclides were performed on the uMI Panorama GS PET/CT system, with the CRC profile across its extended AFOV also evaluated. Following the NEMA NU 2-2018 standard, the image quality was assessed using the NEMA IEC (NEC) Body Phantom with F, Cu, Ga, Zr, I, and Y. The CRC, the background variability (BV), and the lung residual error were measured to quantify the image quality. CRCs were sequentially measured at four axial offsets: 1/2, 1/4, 1/8, and 1/16 of the AFOV. The impact of the radionuclide-specific PSF (point spread function) modeling on the CRC was evaluated by comparing PET images reconstructed with and without PSF modeling. The assessment demonstrated comparable image qualities for F, Cu, Ga, Zr, I, while Y showed a similar CRC but a higher BV and a higher lung residual error, attributable to its low positron branching ratio. The BV and lung residual error increased with increasing axial distance from the AFOV center, whereas CRCs for larger spheres remained stable across AFOV positions; small-sphere CRC measurements exhibited increased dispersion toward the periphery due to reduced count statistics. The PSF modeling significantly improved CRCs for Ga and I, consistent with their long positron ranges. All investigated radionuclides were effectively imaged on the uMI Panorama GS PET/CT system. The AFOV uniformity was quantitatively evaluated based on CRC measurements obtained at multiple positions along the AFOV.
Haiqiong Zhang, Guangjie Yang, Linfeng Li, Meixi Liu, Tong Wang, Xueqian Yang, et al. Quantification of image quality and partial volume effect along the axial field-of-view of uMI Panorama GS PET/CT system for multiple radionuclides.. EJNMMI physics. 2026; doi:10.1186/s40658-026-00915-y.
Haiqiong Zhang, Guangjie Yang, Linfeng Li, Meixi Liu, Tong Wang, Xueqian Yang, et al (2026). Quantification of image quality and partial volume effect along the axial field-of-view of uMI Panorama GS PET/CT system for multiple radionuclides.. EJNMMI physics. https://doi.org/10.1186/s40658-026-00915-y
Haiqiong Zhang, Guangjie Yang, Linfeng Li, Meixi Liu, Tong Wang, Xueqian Yang, et al. Quantification of image quality and partial volume effect along the axial field-of-view of uMI Panorama GS PET/CT system for multiple radionuclides.[J]. EJNMMI physics, 2026 doi:10.1186/s40658-026-00915-y.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出