开发和验证局部麻醉下机器人辅助经皮椎体成形术穿刺准确性的预测模型
Development and validation of a predictive model for puncture accuracy in robot-assisted percutaneous vertebroplasty under local anesthesia.
Development and validation of a predictive model for puncture accuracy in robot-assisted percutaneous vertebroplasty under local anesthesia.
对于骨质疏松性椎体压缩骨折(OVCFs)的治疗,局部麻醉下机器人辅助经皮椎体成形术(PVP)已显示出有效性;然而,穿刺过程的精确性在不同脊柱节段间差异显著,目前尚无工具可评估个体发生不准确穿刺的风险。本研究是对既往已发表队列的二次分析,该队列纳入312例因单节段OVCFs在局部麻醉下接受机器人辅助PVP的患者(2023—2024年),我们开发并内部验证了临床不可接受穿刺(Gertzbein C~E级)的预测模型。患者被随机分为训练队列(n=218)和验证队列(n=94)。候选预测变量包括人口学、影像学及早期术中变量。通过LASSO回归进行特征选择,随后行多因素logistic回归。采用AUC、校准曲线和决策曲线分析评估模型性能,并以Bootstrap法进行内部验证。不可接受穿刺的发生率为11.9%(37/312)。共识别出4个独立预测因素:T1~8椎体节段(OR=4.89,95%CI 2.67~8.95)、椎弓根宽度(每毫米OR=0.71,0.60~0.84)、半定量呼吸运动影响评分(RMIS;每分OR=1.95,1.38~2.76)以及注册与规划时间(每分钟OR=1.32,1.12~1.56)。列线图显示出良好的区分度(训练AUC=0.862,验证AUC=0.841,乐观校正AUC=0.851)和校准度,决策曲线分析显示在5%~65%的阈值概率范围内具有正向净获益。这是首个经内部验证的机器人辅助PVP穿刺准确性模型,可利用术前及术中即时可得的操作变量实现早期术中风险分层。然而,鉴于RMIS成分的半定量和主观性质以及单中心设计,在广泛临床采用前仍需在多中心队列中进行严格的外部验证。
For the treatment of osteoporotic vertebral compression fractures (OVCFs), robot-assisted percutaneous vertebroplasty (PVP) under local anesthesia has shown effectiveness; however, the precision of the puncture process varies significantly across spinal segments, and no tool currently exists to assess an individual's risk of inaccurate puncture. In this secondary analysis of a previously published cohort of 312 patients who underwent robot-assisted PVP for single-level OVCFs under local anesthesia (2023-2024), we developed and internally validated a predictive model for clinically unacceptable puncture (Gertzbein Grade C-E). Patients were randomly split into training (n = 218) and validation (n = 94) cohorts. Candidate predictors included demographic, imaging, and early intraoperative variables. Feature selection was conducted via LASSO regression followed by multivariate logistic regression. Model performance was assessed by AUC, calibration plots, and decision curve analysis, with bootstrapping for internal validation. Unacceptable puncture occurred in 11.9% of cases (37/312). Four independent predictors were identified: T1-8 vertebral segment (OR = 4.89, 95% CI 2.67-8.95), pedicle width (OR = 0.71 per mm, 0.60-0.84), a semi-quantitative Respiratory Motion Impact Score (RMIS; OR = 1.95 per point, 1.38-2.76), and registration and planning time (OR = 1.32 per min, 1.12-1.56). The nomogram demonstrated good discrimination (training AUC = 0.862, validation AUC = 0.841, optimism-corrected AUC = 0.851) and calibration, with decision curve analysis showing positive net benefit across threshold probabilities of 5%-65%. This first internally validated model for puncture accuracy in robot-assisted PVP enables early intraoperative risk stratification using both preoperative and immediately available procedural variables. However, given the semi-quantitative and subjective nature of the RMIS component and the single-center design, rigorous external validation in multi-center cohorts is required before widespread clinical adoption.
Chunyan Zhang, Tairui Zhang, Gen Li, Xuebin Tang, Hua Li, Yunqing Wang, et al. Development and validation of a predictive model for puncture accuracy in robot-assisted percutaneous vertebroplasty under local anesthesia.. Journal of robotic surgery. 2026; doi:10.1007/s11701-026-03460-z.
Chunyan Zhang, Tairui Zhang, Gen Li, Xuebin Tang, Hua Li, Yunqing Wang, et al (2026). Development and validation of a predictive model for puncture accuracy in robot-assisted percutaneous vertebroplasty under local anesthesia.. Journal of robotic surgery. https://doi.org/10.1007/s11701-026-03460-z
Chunyan Zhang, Tairui Zhang, Gen Li, Xuebin Tang, Hua Li, Yunqing Wang, et al. Development and validation of a predictive model for puncture accuracy in robot-assisted percutaneous vertebroplasty under local anesthesia.[J]. Journal of robotic surgery, 2026 doi:10.1007/s11701-026-03460-z.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出