AO/OTA 34 C髌骨骨折可变角度锁定钢板固定早期固定失败率低:一项回顾性队列研究
Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.
Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.
旨在确定可变角度(VA)锁定髌骨钢板的固定失败率,并评估辅助增强固定是否降低固定失败的风险。本研究为一项回顾性对比队列研究,于2021年1月至2025年6月在一级创伤中心开展。纳入接受VA锁定钢板治疗(伴或不伴增强固定)且随访≥3个月的OTA/AO 34 C型髌骨骨折成年患者。增强固定定义为使用附加钢板、独立螺钉、环扎钢丝、粗不可吸收缝线或缝线锚钉来辅助固定和/或加强髌骨下极或伸膝装置。主要结局为固定失败;次要结局包括失败模式、感染及有症状的内固定物取出。共纳入34例患者(单纯VA组17例,VA+增强固定组17例)。两组在年龄、性别、Charlson合并症指数、OTA/AO亚分类、开放性骨折状态及随访时间方面具有可比性(均p > 0.05)。总体固定失败率为2.9%(1/34),发生于增强固定组的远端固定界面。两组间失败率无显著差异(单纯VA组0.0% vs. VA+增强固定组5.9%;p = 1.0)。VA组有1例患者发生骨折相关感染,VA+增强固定组有1例患者发生缝线脓肿。VA+增强固定组有1例患者因有症状的内固定物而需取出内固定物。其余患者均愈合且无并发症。可变角度锁定钢板固定治疗AO/OTA 34 C型髌骨骨折与较低的早期固定失败率和有症状内固定物取出率相关。由于仅记录到1例固定失败,本研究把握度不足,无法就增强固定对固定失败的保护作用得出结论。
To determine the fixation failure rate of the variable-angle (VA) locking patella plate and to evaluate whether supplemental augmentation reduced the risk of fixation failure. A retrospective comparative cohort study was performed at a Level I trauma center between January 2021 and June 2025. Adult patients with OTA/AO 34 C patella fractures treated with a VA locking plate with or without augmentation and ≥ 3 months of follow-up were included. Augmentation was defined as additional plates, independent screws, cerclage wire, heavy non absorbable sutures, or suture anchors that were used to supplement fixation and/or reinforce the inferior patellar pole or extensor mechanism. The primary outcome was fixation failure; secondary outcomes included mode of failure, infection and symptomatic implant removal. Thirty-four patients were included (17 VA-only, 17 VA + augmentation). Groups were comparable for age, sex, Charlson Comorbidity Index, OTA/AO subclassification, open fracture status and follow-up duration (all p > 0.05). The overall fixation failure rate was 2.9% (1/34), occurring at the distal fixation interface in the augmented group. There was no significant difference in failure rate between groups (VA-only 0.0% vs. VA + augmentation 5.9%; p = 1.0). One patient in the VA group suffered a fracture-related infection and one patient in the VA + augmentation cohort had a suture abscess. One patient in the VA + augmentation cohort required hardware removal for symptomatic hardware. All remaining patients healed without complications. Variable-angle locking plate fixation of AO/OTA 34 C patella fractures was associated with low rates of early fixation failure and symptomatic hardware removal. With only a single documented fixation failure, the study was underpowered to draw conclusions regarding the protective role of augmentation on fixation failure.
Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T Kent. Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2026; doi:10.1007/s00590-026-04864-1.
Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T Kent (2026). Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. https://doi.org/10.1007/s00590-026-04864-1
Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T Kent. Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.[J]. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026 doi:10.1007/s00590-026-04864-1.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出