AO/OTA 34 C髌骨骨折可变角度锁定钢板固定早期固定失败率低:一项回顾性队列研究

Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

旨在确定可变角度(VA)锁定髌骨钢板的固定失败率,并评估辅助增强固定是否降低固定失败的风险。本研究为一项回顾性对比队列研究,于2021年1月至2025年6月在一级创伤中心开展。纳入接受VA锁定钢板治疗(伴或不伴增强固定)且随访≥3个月的OTA/AO 34 C型髌骨骨折成年患者。增强固定定义为使用附加钢板、独立螺钉、环扎钢丝、粗不可吸收缝线或缝线锚钉来辅助固定和/或加强髌骨下极或伸膝装置。主要结局为固定失败;次要结局包括失败模式、感染及有症状的内固定物取出。共纳入34例患者(单纯VA组17例,VA+增强固定组17例)。两组在年龄、性别、Charlson合并症指数、OTA/AO亚分类、开放性骨折状态及随访时间方面具有可比性(均p > 0.05)。总体固定失败率为2.9%(1/34),发生于增强固定组的远端固定界面。两组间失败率无显著差异(单纯VA组0.0% vs. VA+增强固定组5.9%;p = 1.0)。VA组有1例患者发生骨折相关感染,VA+增强固定组有1例患者发生缝线脓肿。VA+增强固定组有1例患者因有症状的内固定物而需取出内固定物。其余患者均愈合且无并发症。可变角度锁定钢板固定治疗AO/OTA 34 C型髌骨骨折与较低的早期固定失败率和有症状内固定物取出率相关。由于仅记录到1例固定失败,本研究把握度不足,无法就增强固定对固定失败的保护作用得出结论。

Abstract

To determine the fixation failure rate of the variable-angle (VA) locking patella plate and to evaluate whether supplemental augmentation reduced the risk of fixation failure. A retrospective comparative cohort study was performed at a Level I trauma center between January 2021 and June 2025. Adult patients with OTA/AO 34 C patella fractures treated with a VA locking plate with or without augmentation and ≥ 3 months of follow-up were included. Augmentation was defined as additional plates, independent screws, cerclage wire, heavy non absorbable sutures, or suture anchors that were used to supplement fixation and/or reinforce the inferior patellar pole or extensor mechanism. The primary outcome was fixation failure; secondary outcomes included mode of failure, infection and symptomatic implant removal. Thirty-four patients were included (17 VA-only, 17 VA + augmentation). Groups were comparable for age, sex, Charlson Comorbidity Index, OTA/AO subclassification, open fracture status and follow-up duration (all p > 0.05). The overall fixation failure rate was 2.9% (1/34), occurring at the distal fixation interface in the augmented group. There was no significant difference in failure rate between groups (VA-only 0.0% vs. VA + augmentation 5.9%; p = 1.0). One patient in the VA group suffered a fracture-related infection and one patient in the VA + augmentation cohort had a suture abscess. One patient in the VA + augmentation cohort required hardware removal for symptomatic hardware. All remaining patients healed without complications. Variable-angle locking plate fixation of AO/OTA 34 C patella fractures was associated with low rates of early fixation failure and symptomatic hardware removal. With only a single documented fixation failure, the study was underpowered to draw conclusions regarding the protective role of augmentation on fixation failure.

如何引用

AMA

Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T Kent. Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2026; doi:10.1007/s00590-026-04864-1.

APA

Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T Kent (2026). Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. https://doi.org/10.1007/s00590-026-04864-1

GB/T 7714

Benyamin Dadpey, Kevin Zhu, Claire Bonnyman, Hevatib Mehmood, William T Kent. Low early fixation failure rates with variable-angle locking plate fixation of AO/OTA 34 C patella fractures: a retrospective cohort study.[J]. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026 doi:10.1007/s00590-026-04864-1.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

European journal of orthopaedic surgery & traumatology : orthopedie traumatologie 的其他文献