植物组织中基于多重荧光蛋白的生物传感器的稳健定量
Robust quantification of multiplexed fluorescent protein-based biosensors in plant tissues.
Robust quantification of multiplexed fluorescent protein-based biosensors in plant tissues.
基因编码的生物传感器是生物学研究中的重要工具之一。它们能够实现从亚细胞水平到整个生物体水平的活体内目标分子可视化,并可用于监测小分子存在、基因表达、蛋白质活性及蛋白质降解。然而,由于信号串扰和叶绿素强自发荧光,在植物中进行荧光生物传感器的多重检测极为困难。本研究基于报告荧光蛋白的选择,探讨了生物传感器多重检测的潜力。我们表征了植物叶片中多种荧光蛋白的发射光谱、荧光寿命和相对亮度。结果表明,所选蛋白具有相当的亮度,支持其在共表达实验中的应用以及对单个信号的可靠定量。为分离三个重叠信号,我们应用了两种不同的线性解混方法,并与未解混的结果进行比较。我们确定通道分离解混方法最适合生物传感器。此外,我们展示了如何应用所选解混方法分离自发荧光和五种荧光蛋白。我们进一步在病毒感染细胞中通过追踪活体内细胞器动态验证了该方法。最后,我们利用自定义MATLAB工作流程展示了针对细胞核、叶绿体和细胞质信号分析的高通量分割与定量的可行性。总体而言,我们的工作表明,即使发射光谱重叠,生物传感器也可以实现多重检测。
Genetically encoded biosensors are one of the essential tools in biological research. They enable visualization of molecules of interest from the subcellular level to entire organism level in vivo and can be used to monitor the presence of small molecules, gene expression, protein activity, and protein degradation. However, multiplexing fluorescent biosensors in plants is notoriously difficult due to signal bleed-through and strong autofluorescence from chlorophyll. In this study, we investigated the potential of multiplexing biosensors based on the selection of reporter fluorescent proteins. We characterized the emission spectra, fluorescence lifetimes, and relative brightness of diverse fluorescent proteins in plant leaves. We show that selected proteins exhibit comparable brightness, supporting their use in co-expression experiments and reliable quantification of individual signals. To separate three overlapping signals, we applied two different linear unmixing approaches and compared them to results obtained without unmixing. We identified the channel separation unmixing approach as the most suitable for biosensors. Additionally, we show how unmixing with the selected approach can be applied to separate autofluorescence and five fluorescent proteins. We further validated this approach in virus-infected cells by following organelle dynamics in vivo. Finally, we demonstrate the feasibility of high-throughput segmentation and quantification with a custom MATLAB workflow for nuclei, chloroplasts, and cytoplasm signal analysis. Overall, our work demonstrates that biosensors can be multiplexed, even when their emission spectra overlap.
Valentina Levak, Anže Županič, Karmen Pogačar, Nastja Marondini, Katja Stare, Tina Arnšek, et al. Robust quantification of multiplexed fluorescent protein-based biosensors in plant tissues.. The Plant journal : for cell and molecular biology. 2026; doi:10.1111/tpj.71034.
Valentina Levak, Anže Županič, Karmen Pogačar, Nastja Marondini, Katja Stare, Tina Arnšek, et al (2026). Robust quantification of multiplexed fluorescent protein-based biosensors in plant tissues.. The Plant journal : for cell and molecular biology. https://doi.org/10.1111/tpj.71034
Valentina Levak, Anže Županič, Karmen Pogačar, Nastja Marondini, Katja Stare, Tina Arnšek, et al. Robust quantification of multiplexed fluorescent protein-based biosensors in plant tissues.[J]. The Plant journal : for cell and molecular biology, 2026 doi:10.1111/tpj.71034.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出