扫描体几何形状、植入物角度和植入物间距对上颌全弓数字植入物扫描准确性的影响:一项体外研究

Influence of Scan Body Geometry, Implant Angulation, and Interimplant Distance on the Accuracy of Maxillary Full-Arch Digital Implant Scans: An In Vitro Study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

背景 本研究比较了不同扫描体几何形状在不同种植体角度和种植体间距条件下的准确性。关于这些条件下全牙弓数字化种植体扫描的证据仍然有限。材料与方法 在这项体外研究中,将5枚种植体植入代表3种种植体系统(Bioinfinity、Meisinger和Mode)的上颌无牙颌石膏模型中。参考种植体位于中线处,垂直于牙槽嵴顶。种植体角度(5°和10°)和种植体间距(5 mm和10 mm)均已标准化。将扫描体安装于主模型上,每个模型使用口内扫描仪(TRIOS 5)扫描10次。计算三维偏差。数据采用单因素方差分析和Tukey HSD检验进行分析(α=0.05)。结果 在5°角度下,各组间未观察到显著差异(P>0.05),而在10°角度下,种植体1和5检测到显著差异(P<0.01)。Bioinfinity在种植体1处显示较高的偏差值,而Meisinger在种植体5处显示较高的偏差。在10 mm种植体间距下(种植体1和2),各组间发现显著差异(P<0.001),其中Bioinfinity表现出较低的偏差值。在5 mm间距下,种植体4处未观察到显著差异(P>0.05),而种植体5处发现显著差异(P<0.001),Meisinger组偏差最高。结论 种植体角度和种植体间距增加与数字化全牙弓扫描准确性降低和偏差值升高相关。扫描体几何形状的影响因种植体位置而异。

Abstract

BACKGROUND This study compared the accuracy of different scan body geometries under different implant angulation and interimplant distance conditions. Evidence regarding full-arch digital implant scanning under these conditions remains limited. MATERIAL AND METHODS In this in vitro study, 5 implants were placed in maxillary edentulous plaster models representing 3 implant systems (Bioinfinity, Meisinger, and Mode). The reference implant was positioned perpendicular to the ridge crest at the midline. Implant angulations (5° and 10°) and interimplant distances (5 mm and 10 mm) were standardized. Scan bodies were attached to the master model, and each model was scanned 10 times using an intraoral scanner (TRIOS 5). Three-dimensional deviations were calculated. Data were analyzed using 1-way ANOVA and Tukey HSD tests (alpha=0.05). RESULTS No significant differences were observed among the groups at 5° angulation (P>0.05), whereas significant differences were detected at 10° angulation for implants 1 and 5 (P<0.01). Bioinfinity showed higher deviation values at implant 1, while Meisinger demonstrated higher deviations at implant 5. At a 10-mm interimplant distance (implants 1 and 2), significant differences were found among the groups (P<0.001), with Bioinfinity exhibiting lower deviation values. At a 5-mm distance, no significant difference was observed at implant 4 (P>0.05), whereas a significant difference was found at implant 5 (P<0.001), with the highest deviation in the Meisinger group. CONCLUSIONS Increased implant angulation and interimplant distance are associated with reduced accuracy and higher deviation values in digital full-arch scans. The influence of scan body geometry varies depending on implant position.

如何引用

AMA

Ebru Sümer Ekin, Sozdar Başkan Uyar, Merve Güler, Emrah Ayna. Influence of Scan Body Geometry, Implant Angulation, and Interimplant Distance on the Accuracy of Maxillary Full-Arch Digital Implant Scans: An In Vitro Study.. Medical science monitor : international medical journal of experimental and clinical research. 2026; doi:10.12659/MSM.953734.

APA

Ebru Sümer Ekin, Sozdar Başkan Uyar, Merve Güler, Emrah Ayna (2026). Influence of Scan Body Geometry, Implant Angulation, and Interimplant Distance on the Accuracy of Maxillary Full-Arch Digital Implant Scans: An In Vitro Study.. Medical science monitor : international medical journal of experimental and clinical research. https://doi.org/10.12659/MSM.953734

GB/T 7714

Ebru Sümer Ekin, Sozdar Başkan Uyar, Merve Güler, Emrah Ayna. Influence of Scan Body Geometry, Implant Angulation, and Interimplant Distance on the Accuracy of Maxillary Full-Arch Digital Implant Scans: An In Vitro Study.[J]. Medical science monitor : international medical journal of experimental and clinical research, 2026 doi:10.12659/MSM.953734.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Medical science monitor : international medical journal of experimental and clinical research 的其他文献