基于气体图谱区分肿瘤状态的诊断参数稳定性评估
Stability assessment of diagnostic parameters for differentiation of oncological status based on gas profile.
Stability assessment of diagnostic parameters for differentiation of oncological status based on gas profile.
传感器阵列的长期稳定性仍然是将电子鼻系统实际应用于挥发性有机化合物(VOCs)无创分析及肿瘤状态鉴别的主要限制因素。传感层在长时间运行过程中理化性质的改变可能改变诊断参数并损害分类一致性。本研究评估了使用基于量子点的电子鼻进行皮肤气体谱分析所获得的具有诊断意义参数的长期稳定性。采用基于硫化镉量子点并配有不同修饰剂的八传感器压电电子鼻阵列,对志愿者和癌症患者进行皮肤气体谱分析。通过比较初步研究期间获得的测量结果与传感器运行两年后的测量结果,评估了配对灵敏度参数(Ai/j)和由计时频率响应衍生的动力学吸附参数。配对灵敏度参数对长期表面降解和环境变异性(尤其是湿度)表现出显著敏感性,导致明显的分类漂移。相比之下,动力学吸附参数表现出更高的时间稳定性和对操作条件的较低敏感性。开发了一种基于动力学参数系统性变化的校正策略,并将其应用于补偿传感器老化效应。所提出的方法减少了分类漂移。这些发现表明,校正长期传感器漂移可能有助于延长基于量子点的电子鼻系统的运行寿命,而动力学参数可能为气体谱分析提供更稳定的分析指标。
Long-term stability of sensor arrays remains a major limitation for the practical implementation of electronic nose systems in non-invasive analysis of volatile organic compounds (VOCs) and differentiation of oncological status. Changes in the physicochemical properties of sensing layers during prolonged operation may alter diagnostic parameters and compromise classification consistency. This study evaluated the long-term stability of diagnostically significant parameters obtained from skin gas-profile analysis using a quantum dot-based electronic nose. An eight-sensor piezoelectric electronic nose array based on cadmium sulfide quantum dots with various modifiers was used for skin gas-profile analysis of volunteers and cancer patients. Pair sensitivity parameters (Ai/j) and kinetic sorption parameters derived from chronofrequency responses were assessed by comparing measurements obtained during the pilot study and after two years of sensor operation. Pair sensitivity parameters demonstrated substantial susceptibility to long-term surface degradation and environmental variability, particularly humidity, resulting in pronounced classification drift. In contrast, kinetic sorption parameters exhibited higher temporal stability and lower sensitivity to operating conditions. A correction strategy based on systematic changes in kinetic parameters was developed and applied to compensate for sensor aging effects. The proposed approach reduced classification drift. These findings indicate that correction of long-term sensor drift may help extend the operational lifetime of quantum dot-based electronic nose systems, while kinetic parameters may provide more stable analytical indicators for gas-profile analysis.
T A Kuchmenko, T N Khmelevskaya, A A Klimovich, K G Puzakov. Stability assessment of diagnostic parameters for differentiation of oncological status based on gas profile.. Talanta. 2027; doi:10.1016/j.talanta.2026.130303.
T A Kuchmenko, T N Khmelevskaya, A A Klimovich, K G Puzakov (2027). Stability assessment of diagnostic parameters for differentiation of oncological status based on gas profile.. Talanta. https://doi.org/10.1016/j.talanta.2026.130303
T A Kuchmenko, T N Khmelevskaya, A A Klimovich, K G Puzakov. Stability assessment of diagnostic parameters for differentiation of oncological status based on gas profile.[J]. Talanta, 2027 doi:10.1016/j.talanta.2026.130303.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出