通过整合质子转移电荷减少和高能碰撞解离(PTCR-HCD MS3),改进了天然环境质谱中的蛋白质鉴定
Improved Protein Identification in Native Ambient Mass Spectrometry by the Integration of Proton Transfer Charge Reduction and Higher-Energy Collision Dissociation (PTCR-HCD MS3).
Improved Protein Identification in Native Ambient Mass Spectrometry by the Integration of Proton Transfer Charge Reduction and Higher-Energy Collision Dissociation (PTCR-HCD MS3).
在此,我们展示PTCR-HCD MS3作为一种改善原生环境质谱(NAMS)中蛋白质鉴定的工具。NAMS涉及对组织切片进行直接分析,几乎无需或仅需极少样品制备,且采样后无需(溶液相)分离。因此,NAMS样品高度复杂,包含蛋白质、盐类和其他生物分子,NAMS谱图高度拥挤。PTCR MS已成为自上而下蛋白质组学中的一种有用策略。最常见的是,它作为辅助MS2步骤应用,提供分子量信息以支持基于碰撞的MS2所提供的序列信息,或作为MS3步骤应用,通过减少产物离子的m/z重叠来简化基于碰撞、光子或电子的MS2。在本工作中,我们表明,选择电荷降低的PTCR产物离子进行后续HCD可降低嵌合碎裂谱图的发生率,并提高对小鼠脊髓、大鼠肾脏和细胞系来源异种移植组织NAMS样品中蛋白质鉴定的置信度。除了消除重叠蛋白质种类的干扰外,我们还表明PTCR-HCD MS3还可消除重叠脂质种类的干扰,后者同样可能影响可靠的蛋白质鉴定。该方法还允许鉴定在MS1水平被掩盖但经PTCR后显现的蛋白质。
Here, we demonstrate PTCR-HCD MS3 as a tool for improving protein identification in native ambient mass spectrometry (NAMS). NAMS involves the direct analysis of tissue sections with no or little sample preparation and no (solution-phase) separation postsampling. NAMS samples are therefore highly complex, comprising proteins, salts, and other biomolecules, and NAMS spectra are highly congested. PTCR MS has emerged as a useful strategy in top-down proteomics. Most commonly, it is applied as an adjunct MS2 step, providing molecular weight information to support sequence information provided by collision-based MS2 or it is applied as an MS3 step to simplify collision, photon, or electron-based MS2 by reducing m/z overlap of product ions. In this work, we show that the selection of charge-reduced PTCR product ions for subsequent HCD reduces the incidence of chimeric fragmentation spectra and improves confidence in protein identification in NAMS samples from mouse spinal cord, rat kidney, and cell-line-derived xenograft tissue. As well as removing interference from overlapping protein species, we show that PTCR-HCD MS3 also removes interference from overlapping lipid species which can similarly affect confident protein identification. The approach also allows identification of proteins that are masked at the MS1 level but are revealed following PTCR.
Rebecca L Edwards, Oliver J Hale, Sarah R W Vickers, Helen J Cooper. Improved Protein Identification in Native Ambient Mass Spectrometry by the Integration of Proton Transfer Charge Reduction and Higher-Energy Collision Dissociation (PTCR-HCD MS3).. Journal of the American Society for Mass Spectrometry. 2026; doi:10.1021/jasms.6c00165.
Rebecca L Edwards, Oliver J Hale, Sarah R W Vickers, Helen J Cooper (2026). Improved Protein Identification in Native Ambient Mass Spectrometry by the Integration of Proton Transfer Charge Reduction and Higher-Energy Collision Dissociation (PTCR-HCD MS3).. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1021/jasms.6c00165
Rebecca L Edwards, Oliver J Hale, Sarah R W Vickers, Helen J Cooper. Improved Protein Identification in Native Ambient Mass Spectrometry by the Integration of Proton Transfer Charge Reduction and Higher-Energy Collision Dissociation (PTCR-HCD MS3).[J]. Journal of the American Society for Mass Spectrometry, 2026 doi:10.1021/jasms.6c00165.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出