双能CT结合金属伪影减少技术在EVAR术后CTA随访中的应用:一项图像质量分析的前瞻性研究

Dual-energy CT with metal artifact reduction for post-EVAR CTA surveillance: a prospective study with image quality analysis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估双能计算机断层扫描(DECT)联合迭代金属伪影去除(iMAR)在腹主动脉腔内修复术(EVAR)术后CT血管造影(CTA)随访中的价值。本前瞻性研究采用西门子Force CT(100/150 kVp双能)进行EVAR术后CTA随访。图像重建为常规混合图像及40-190 keV虚拟单能图像(VMI),分别在有和无iMAR条件下进行。通过定量参数和5分主观评分评估图像质量,同时记录临床数据和辐射剂量。诊断效能以手术/数字减影血管造影(DSA)结果及盲法专家裁定为参考标准。统计分析采用双因素重复测量方差分析(ANOVA),事后检验采用配对t检验或Wilcoxon检验分析定量参数;主观评分采用Friedman检验,事后采用Wilcoxon符号秩检验。P值经Bonferroni校正;校正后P<0.05表示差异有统计学意义。50例EVAR术后患者(82%为男性;年龄68.7±8.9岁)接受了安全的辐射剂量;支架类型未产生定量差异(P>0.05)。iMAR与DECT协同增强图像质量,其改善与伪影严重程度呈正相关,同时iMAR对正常组织无影响。能量水平主导变化趋势:多数参数在40-70 keV迅速下降,但在100 keV以上趋于平台。iMAR在伪影减少评分(150-190 keV趋于平台)和血管可见性评分(90 keV达峰值,P<0.01)方面显著优于非iMAR。在诊断方面,iMAR+DECT将5例假阴性转为真阳性(内漏、血栓形成、感染),显示出较非iMAR+DECT更高敏感性的趋势(P>0.05,效应量大)。DECT-VMI与iMAR算法的整合似乎通过有效减少支架相关金属伪影并增强血管和软组织可视化,改善了EVAR术后CTA的图像质量。基于我们的定量和定性评估,90 keV(有效范围80-100 keV)可被视为优化诊断评估的最佳能量水平,尚需在更大规模的多中心队列中验证。

Abstract

To evaluate the value of dual-energy computed tomography (DECT) combined with the iterative metal artifact reduction (iMAR) for postoperative endovascular aortic repair (EVAR) CT angiography (CTA) surveillance. In this prospective study, post-EVAR CTA surveillance was performed using a Siemens Force CT (100/150 kVp dual-energy). Images were reconstructed as conventional mixed and 40-190 keV virtual monoenergetic images (VMIs), with and without iMAR. Image quality was assessed via quantitative parameters and 5-point subjective scores, with clinical data and radiation dose recorded simultaneously. Diagnostic performance was referenced to surgical/DSA findings and blinded expert adjudication. Statistical analysis was performed via two-way repeated-measures ANOVA with post-hoc paired t-tests or Wilcoxon tests for quantitative parameters, While subjective scores were analyzed using the Friedman test with post-hoc Wilcoxon signed-rank tests. P values were Bonferroni-corrected; corrected P < 0.05 indicated significance. Fifty post-EVAR patients (82% male; 68.7 ± 8.9 years) received safe radiation doses; stent type yielded no quantitative differences (P > 0.05). iMAR-DECT synergistically enhanced image quality, with improvements correlating positively with artifact severity while sparing normal tissues for iMAR. Energy levels dominated the trend: most parameters declined rapidly at 40-70 keV but plateaued beyond 100 keV. iMAR significantly outperformed non-iMAR in scores of artifact reduction (plateauing at 150-190 keV) and vessel visibility (peaking at 90 keV, P < 0.01). For diagnosis, iMAR+DECT converted five false negatives into true positives (endoleaks, thrombosis, infection), showing a trend toward higher sensitivity than those for non-iMAR+DECT (P > 0.05, large effect size). The integration of DECT-VMIs with the iMAR algorithm appears to improve image quality in post-EVAR CTA by effectively reducing stent-related metal artifacts while enhancing vascular and soft-tissue visualization. Based on our quantitative and qualitative assessments, an energy level of 90 keV (effective range 80-100 keV) may be considered optimal to optimize diagnostic evaluation, pending validation in larger, multi-center cohorts.

如何引用

AMA

Dingxiang Xie, Xiaofang Chen, Jinzhu Wang, Chao Jiang, Lina Chen, Jing Zhao, et al. Dual-energy CT with metal artifact reduction for post-EVAR CTA surveillance: a prospective study with image quality analysis.. Abdominal radiology (New York). 2026; doi:10.1007/s00261-026-05683-y.

APA

Dingxiang Xie, Xiaofang Chen, Jinzhu Wang, Chao Jiang, Lina Chen, Jing Zhao, et al (2026). Dual-energy CT with metal artifact reduction for post-EVAR CTA surveillance: a prospective study with image quality analysis.. Abdominal radiology (New York). https://doi.org/10.1007/s00261-026-05683-y

GB/T 7714

Dingxiang Xie, Xiaofang Chen, Jinzhu Wang, Chao Jiang, Lina Chen, Jing Zhao, et al. Dual-energy CT with metal artifact reduction for post-EVAR CTA surveillance: a prospective study with image quality analysis.[J]. Abdominal radiology (New York), 2026 doi:10.1007/s00261-026-05683-y.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI