连续波fNIRS光学自适应深度调控的计算验证

Computational validation of optical adaptive depth steering for continuous-wave fNIRS.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

连续波功能近红外光谱(CW-fNIRS)传统上采用固定几何形状的光极配置,这因受试者间颅骨厚度差异以及浓密毛发等表型障碍而引入显著的解剖学偏倚。为解决这些局限性,我们提出了一种光学自适应深度引导(O-ADS)框架,该框架利用高密度多距离阵列(8–32 mm)和线性约束最小方差(LCMV)空间波束形成器,以数学方式合成“虚拟光极”。我们通过在分层颅骨平板和三维解剖图谱(Colin27)上进行高保真蒙特卡洛模拟,对该框架进行了计算验证。结果表明,O-ADS对解剖学偏倚表现出较高的计算鲁棒性,与传统的32 mm静态传感器相比,在厚颅骨形态下相对脑敏感性提升高达39倍。此外,在涉及异质性头皮血流动力学和模拟表型障碍(8 mm参考通道失效)的真实时空噪声条件下,O-ADS保持了显著更高的平均信号恢复纯度(38.3% ± 22.1%),优于标准多距离回归(MDR)(21.8% ± 15.4%)。这种软件定义的方法为光学神经成像提供了一种可扩展的解决方案,降低了传感器性能对个体解剖学和表型变异的依赖,从而有助于在具有挑战性的物理约束下实现更具包容性的脑监测。

Abstract

Continuous-wave functional near-infrared spectroscopy (CW-fNIRS) traditionally utilizes fixed-geometry optode configurations, which introduce significant anatomical bias due to inter-subject variations in skull thickness and phenotypic barriers such as dense hair. To address these limitations, we propose an Optical Adaptive Depth Steering (O-ADS) framework that mathematically synthesizes a "Virtual Optode" using a high-density multi-distance array (8-32 mm) and a linearly constrained minimum variance (LCMV) spatial beamformer. We computationally validated this framework using high-fidelity Monte Carlo simulations on layered cranial slabs and a 3D anatomical atlas (Colin27). Results demonstrate that O-ADS exhibits high computational resilience to anatomical bias, achieving up to a 39-fold improvement in relative brain sensitivity for thick-skull morphologies compared to traditional 32 mm static sensors. Furthermore, under realistic spatiotemporal noise conditions involving heterogeneous scalp hemodynamics and simulated phenotypic barriers (8 mm reference channel failure), O-ADS maintained a significantly higher mean signal recovery purity (38.3% ± 22.1%) than standard Multi-Distance Regression (MDR) (21.8% ± 15.4%). This software-defined approach provides a scalable solution for optical neuroimaging, reducing the dependence of sensor performance on individual anatomical and phenotypic variance to facilitate more inclusive cerebral monitoring under challenging physical constraints.

如何引用

AMA

Murad Althobaiti. Computational validation of optical adaptive depth steering for continuous-wave fNIRS.. Biomedical optics express. 2026; doi:10.1364/BOE.604286.

APA

Murad Althobaiti (2026). Computational validation of optical adaptive depth steering for continuous-wave fNIRS.. Biomedical optics express. https://doi.org/10.1364/BOE.604286

GB/T 7714

Murad Althobaiti. Computational validation of optical adaptive depth steering for continuous-wave fNIRS.[J]. Biomedical optics express, 2026 doi:10.1364/BOE.604286.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Biomedical optics express 的其他文献