动脉粥样硬化仍然是心血管疾病(CVD)死亡和发病的主要原因。颈动脉斑块的超声灰阶中位数(GSM)和斑块大小已显示出作为易损性标志物和脑血管事件预测指标的潜力。本前瞻性研究探讨了颈动脉斑块大小、狭窄程度(DoS)与GSM之间的相关性。本研究招募了32例患者,经B型超声识别出43个颈动脉斑块。对每幅B型超声图像进行归一化处理,并使用Adobe Photoshop中的直方图功能定量颈动脉斑块回声的GSM。获取最厚斑块区域的GSM数据,并使用ImageJ软件测量斑块长度、厚度、面积和DoS。采用Spearman相关系数识别和评估斑块大小、DoS与GSM之间的相关性。观察到颈动脉斑块GSM与斑块大小之间存在显著负相关(斑块长度,r = -0.34,p = 0.02;斑块厚度,r = -0.30,p = 0.04;斑块面积,r = -0.40,p = 0.008),与DoS呈接近显著的负相关趋势(r = -0.26,p = 0.08)。本研究发现了颈动脉斑块GSM与斑块大小参数之间的反向关系,表明以较低GSM值为特征的低回声斑块通常较大,且可能更易发生破裂。这些发现强调了将结构指标(如斑块大小和狭窄程度)与成分评估及其回声性相结合对于全面脑血管风险评估的重要性。低回声斑块通常对应于富含脂质、伴有炎症且纤维帽较薄的病变,这些组织学特征与脑血管事件风险增加相关。所证实的关联凸显了GSM作为一种无创替代生物标志物的临床相关性,其反映了局部斑块易损性和动脉粥样硬化的整体系统性负担。因此,B型超声衍生的GSM是一种实用且信息丰富的工具,可用于增强颈动脉疾病患者的风险分层并指导管理策略。我们的研究结果揭示了颈动脉GSM与斑块大小参数之间存在显著负相关,而DoS则呈非显著趋势。这些发现表明,以较低GSM值为特征的低回声斑块通常体积较大,且可能更易损。未来需要开展大规模纵向研究并进行重复评估以验证这些发现。
Atherosclerosis remains a leading cause of Cardiovascular Disease (CVD) mortality and morbidity. Ultrasound Gray-Scale Median (GSM) of carotid plaques and plaque size have shown potential as markers of vulnerability and predictors of cerebrovascular events. This prospective study investigated the correlation between carotid plaque size, Degree of Stenosis (DoS), and GSM. In this study, 32 patients with 43 carotid plaques identified by B-mode ultrasound were recruited. Each B-mode ultrasound image was normalized, and the GSM of carotid plaque echogenicity was quantified using the histogram feature in Adobe Photoshop. GSM data from the thickest plaque area were obtained, and plaque length, thickness, area, and DoS were measured using ImageJ software. Correlations between plaque size, DoS, and GSM were identified and assessed using Spearman's correlation coefficient. Significant negative correlations were observed between carotid plaque GSM and plaque size (plaque length, r = -0.34, p = 0.02; plaque thickness, r = -0.30, p = 0.04; plaque area, r = -0.40, p = 0.008), with a trend toward significant negative correlation with DoS (r = -0.26, p = 0.08). This study identifies an inverse relationship between carotid plaque GSM and plaque size parameters, indicating that hypoechoic plaques, characterized by lower GSM values, are generally larger and potentially more vulnerable to rupture. These findings emphasize the importance of combining structural metrics, such as plaque size and degree of stenosis, with compositional evaluation and their echogenicity for comprehensive cerebrovascular risk assessment. Hypoechoic plaques often correspond to lipid-rich, inflamed lesions with thin fibrous caps, which are histological features associated with an increased risk of cerebrovascular events. The demonstrated associations underscore the clinical relevance of GSM as a noninvasive surrogate biomarker that reflects both local plaque vulnerability and the broader systemic burden of atherosclerosis. Thus, the B-mode ultrasound-derived GSM is a practical and informative tool for enhancing risk stratification and guiding management strategies in patients with carotid artery disease. Our findings reveal significant negative correlations between carotid GSM and plaque size parameters, with a nonsignificant trend for DoS. These findings suggest that hypoechoic plaques, characterized by lower GSM values, are generally larger in size and potentially more vulnerable. Future large-scale longitudinal studies with repeated evaluations are required to validate these findings.
Salahaden R Sultan. Association of Carotid Plaque Gray-scale Median with Plaque Size and Degree of Stenosis.. Current medical imaging. 2026; doi:10.2174/0115734056424582260218072204.
Salahaden R Sultan (2026). Association of Carotid Plaque Gray-scale Median with Plaque Size and Degree of Stenosis.. Current medical imaging. https://doi.org/10.2174/0115734056424582260218072204
Salahaden R Sultan. Association of Carotid Plaque Gray-scale Median with Plaque Size and Degree of Stenosis.[J]. Current medical imaging, 2026 doi:10.2174/0115734056424582260218072204.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出