评估使用CODUBIX®EBRA、CODUBIX®S EBRA肋骨假体的有效性和安全性

{"_":"Evaluation of the Effectiveness and Safety of the Use of CODUBIX ŻEBRA, CODUBIX S ŻEBRA Rib Bone Prostheses.","sup":["®","®"]}

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

Codubix ŻEBRA和Codubix S ŻEBRA假体(由Tricomed SA生产)由生物相容性聚丙烯-聚酯编织物制成,是用于治疗癌症手术或机械性损伤所致骨缺损的工具。本回顾性分析研究介绍了由针织聚酯-聚丙烯织物制成的肋骨假体用于填充肋骨和胸骨缺损的有效性和安全性。数据收集自三个临床中心接受手术的113例患者(68例男性,45例女性)。假体植入用于桥接肋骨和/或胸骨骨缺损。分析包括术前和术中数据、两次随访访视及最终患者访谈。所有假体均采用两种胸壁缺损填充技术植入:87例患者采用“吊床”(悬吊)固定法,26例患者采用“刚性”固定法。缺损的主要原因是为肉瘤、鳞状细胞癌和硬纤维瘤病例实施的癌症手术(95.6%)。其他原因(如先天性缺损和机械性创伤)较少见。与悬吊法相比,“刚性”固定法使手术时间延长约16分钟。恢复期也观察到差异——“吊床”法平均56天,“刚性”法平均30天。在第二次随访访视中,使用这些假体的治疗结果在90.3%的病例中被评为良好。无论采用何种植入方法,平均住院时间均为21天。未报告假体相关不良事件。术后最初几天在21例中观察到并发症。最常见的是感觉障碍(5.3%)、感染(3.5%)、血肿和血液渗出(2.7%)。一项回顾性研究表明,针织假体是修复由肿瘤、创伤或先天性畸形引起的大面积缺损的安全有效解决方案。该植入物确保患者高度舒适,并在无干扰的情况下维持正常身体功能。

Abstract

The Codubix ŻEBRA and Codubix S ŻEBRA prostheses (by Tricomed SA), made of a biocompatible polypropylene-polyester braid, were developed as tools for the treatment of bone defects resulting from cancer surgery or mechanical injuries. The retrospective analysis investigation presents the efficacy and safety of rib bone prostheses made of knitted polyester-polypropylene fabric used to fill defects in the ribs and sternum. Data were collected from 113 patients (68 males, 45 females) undergoing surgery at three clinical centres. Prosthesis implantation was performed to bridge bone defects in the ribs and/or sternum. The analysis included preoperative and intraoperative data, two follow-up visits and a final interview with the patients. All prostheses were implanted using two techniques for filling defects in the chest wall: the 'hammock' (suspension) fixation method in 87 patients, and the 'rigid' fixation method in 26 patients. The main cause of defects was cancer surgery (95.6%) performed in cases of sarcomas, squamous cell carcinomas, and desmoid tumours. Other causes (e.g., congenital defects and mechanical trauma) were less common. The 'rigid' fixation method extended the surgery time by approximately 16 min compared to the suspension method. Differences were also noted in the recovery period-an average of 56 days for the 'hammock' method and 30 days for the 'rigid' method. During the second follow-up visit, the treatment outcome using these prostheses was rated as good in 90.3% of cases. The average duration of hospitalisation was 21 days, regardless of the implantation method. No prosthesis-related adverse events were reported. Complications were observed in 21 cases in the first days after surgery. The most common ones were sensory disturbances (5.3%), infections (3.5%), haematomas and blood effusions (2.7%). A retrospective study demonstrates that knitted prostheses are safe and effective solution for repairing extensive defects resulting from tumours, trauma or congenital malformations. The implants ensure high patient comfort and maintain normal physical functioning without interference.

如何引用

AMA

Tadeusz Orłowski, Marcin Zieliński, Janusz Włodarczyk, Piotr Kasprzak, Magdalena Tokarska, Kaja Jezierska, et al. {"_":"Evaluation of the Effectiveness and Safety of the Use of CODUBIX ŻEBRA, CODUBIX S ŻEBRA Rib Bone Prostheses.","sup":["®","®"]}. Journal of clinical medicine. 2026; doi:10.3390/jcm15135297.

APA

Tadeusz Orłowski, Marcin Zieliński, Janusz Włodarczyk, Piotr Kasprzak, Magdalena Tokarska, Kaja Jezierska, et al (2026). {"_":"Evaluation of the Effectiveness and Safety of the Use of CODUBIX ŻEBRA, CODUBIX S ŻEBRA Rib Bone Prostheses.","sup":["®","®"]}. Journal of clinical medicine. https://doi.org/10.3390/jcm15135297

GB/T 7714

Tadeusz Orłowski, Marcin Zieliński, Janusz Włodarczyk, Piotr Kasprzak, Magdalena Tokarska, Kaja Jezierska, et al. {"_":"Evaluation of the Effectiveness and Safety of the Use of CODUBIX ŻEBRA, CODUBIX S ŻEBRA Rib Bone Prostheses.","sup":["®","®"]}[J]. Journal of clinical medicine, 2026 doi:10.3390/jcm15135297.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of clinical medicine 的其他文献