新冠肺炎患者经颅多普勒检查结果:一项前瞻性观察性研究

Transcranial Doppler findings in patients with COVID-19: a prospective observational study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

经颅多普勒(TCD)是一种用于检测颅内循环中实时自发性微栓子信号(MESs)的诊断工具。重症2019冠状病毒病(COVID-19)患者由于全身性炎症和高凝状态,可能出现微栓子信号增加的风险。旨在评估伴或不伴COVID-19患者的微栓子信号及其他TCD参数,包括脑血流速度(CBFV)、搏动指数和阻力指数,并计算估测脑灌注压(eCPP)。对重症监护病房(ICU)中确诊COVID-19感染的成年患者双侧大脑中动脉(MCAs)进行为期1小时的TCD监测。估测脑灌注压的计算方法为:平均动脉压(MAP)乘以舒张末期流速与平均脑血流速度的比值,再加14 mmHg。共评估31名受试者:11名气管插管的COVID-19患者、10名未插管的COVID-19患者和10名气管插管的非COVID-19患者。患者年龄范围为29至84岁(中位数:62;四分位距[IQR]:50-70),其中64.5%为男性。共有17名(54.8%)受试者在住院期间死亡,2名患者(6.45%)经颞窗未获得超声信号。未检测到微栓子信号。大脑中动脉阻力指数(r = 0.390)与D-二聚体(p = 0.049)之间呈正相关。相反,直接胆红素(r = -0.494)、C反应蛋白(CRP;r = -0.540)、活化部分凝血活酶时间(aPTT;r = -0.495)和D-二聚体(r = -0.439)与估测脑灌注压呈负相关。本队列中未观察到自发性脑微栓子,但直接胆红素、CRP、aPTT和D-二聚体较高的患者估测脑灌注压较低。

Abstract

Transcranial Doppler (TCD) is a diagnostic tool to detect real-time spontaneous microembolic signals (MESs) in intracranial circulation. Critically-ill coronavirus disease 2019 (COVID-19) patients may present an increased likelihood of MESs due to systemic inflammation and hypercoagulability. To assess the presence of MESs and other TCD parameters, including cerebral blood flow velocity (CBFV), pulsatility, and resistance indices, and to calculate the estimated cerebral perfusion pressure (eCPP) in patients with and without COVID-19. The TCD monitoring was performed for 1 hour in both middle cerebral arteries (MCAs) of adult patients in the Intensive Care Unit (ICU) with confirmed COVID-19 infection. The eCPP was calculated by multiplying the mean arterial pressure (MAP) by the ratio of end-diastolic velocity to mean CBFV, then adding 14 mmHg. We evaluated 31 subjects: 11 intubated COVID-19 patients, 10 non-intubated COVID-19 patients, and 10 intubated non-COVID-19 patients. Patient ages ranged from 29 to 84 (median: 62; interquartile range [IQR]: 50-70) years, with 64.5% being male individuals. A total of 17 (54.8%) subjects died during hospitalization, and 2 patients (6.45%) lacked an ultrasonographic signal via the transtemporal window. No MESs were detected. A positive correlation was found between the resistance index of MCAs ( = 0.390) and D-dimer ( = 0.049). In contrast, direct bilirubin ( = -0.494), C-reactive protein (CRP; = -0.540), activated partial thromboplastin time (aPTT; = -0.495), and D-dimer ( = -0.439) were negatively correlated with eCPP. No spontaneous cerebral microemboli were observed in this cohort, but patients with higher direct bilirubin, CRP, aPTT, and D-dimer presented lower eCPP.

如何引用

AMA

Marcella Barreto Santos, Ana Flávia Silveira, João Brainer Clares de Andrade, Eva Carolina Rocha, Fabiano Moulin de Moraes, Hanna Nery Ferraz Martins, et al. Transcranial Doppler findings in patients with COVID-19: a prospective observational study.. Arquivos de neuro-psiquiatria. 2026; doi:10.1055/s-0046-1825526.

APA

Marcella Barreto Santos, Ana Flávia Silveira, João Brainer Clares de Andrade, Eva Carolina Rocha, Fabiano Moulin de Moraes, Hanna Nery Ferraz Martins, et al (2026). Transcranial Doppler findings in patients with COVID-19: a prospective observational study.. Arquivos de neuro-psiquiatria. https://doi.org/10.1055/s-0046-1825526

GB/T 7714

Marcella Barreto Santos, Ana Flávia Silveira, João Brainer Clares de Andrade, Eva Carolina Rocha, Fabiano Moulin de Moraes, Hanna Nery Ferraz Martins, et al. Transcranial Doppler findings in patients with COVID-19: a prospective observational study.[J]. Arquivos de neuro-psiquiatria, 2026 doi:10.1055/s-0046-1825526.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Arquivos de neuro-psiquiatria 的其他文献