自动化偏见的实际表现:人类在有或无人工智能提示下阅读乳腺X线筛查图像的眼动追踪研究
Automation Bias in Action: Eye Tracking of Humans Reading Screening Mammograms with and without AI Prompts.
Automation Bias in Action: Eye Tracking of Humans Reading Screening Mammograms with and without AI Prompts.
背景 不正确的人工智能(AI)建议可能导致自动化偏差;然而,其对医学图像解读的影响研究不足。目的 评估不正确的AI建议如何影响读者解读筛查性乳腺X线摄影时的诊断准确性、阅读时间和视觉搜索行为。材料与方法 在这项于2024年9月至2025年2月进行的回顾性多读者配对研究中,10名英国国家卫生服务体系乳腺筛查计划的乳腺X线摄影读者评估了一组包含双视图乳腺X线摄影筛查检查的测试集。该测试集包括经3年随访或组织病理学分析证实的真阳性(TP)、假阴性(FN)、假阳性(FP)和真阴性(TN)AI建议。在第一轮中,读者在没有AI辅助的情况下解读病例。在6周后进行的第二轮中,使用市售AI工具作为决策支持,显示区域评分≥10(量表0-100)的提示。眼动追踪摄像头记录了读者对特定图像区域的注视——持续凝视。使用Wilcoxon符号秩检验进行轮次间的配对比较,使用Kruskal-Wallis检验比较具有不同AI结果的病例。结果 测试集(n=60)包括26个TP、14个FN、14个FP和6个TN AI建议的病例。在阅读带有FN AI建议的病例时,读者的中位敏感性(39%)低于无辅助阅读(71%;P=.002)。对于带有FP AI建议的病例,读者特异性更高(39% vs 21%;P=.004)。更多可见的(TP和FP)AI提示导致更长的中位阅读时间,从25秒(零个提示)延长至34秒(四个或更多提示)(P=.001)。与无辅助阅读相比,读者在审查AI未能检测到的癌症病例(FN建议)时注视较少(每秒0.44 vs 0.47次注视;P=.03)。与无辅助阅读相比,读者在解读带有FP AI建议的病例时观察到更短的注视持续时间(0.54 vs 0.56秒;P=.001)。结论 不正确的AI建议影响了乳腺X线摄影解读过程中读者的准确性和视觉搜索行为。FN AI建议观察到最大的负面影响;因此,应相应校准AI阈值。© RSNA,2026 另见本期Clauser的社论。另见本期Abbasi和Giess的社论。
Background Incorrect artificial intelligence (AI) suggestions can lead to automation bias; however, their impact on medical image interpretation is underresearched. Purpose To assess how incorrect AI suggestions influence the diagnostic accuracy, read times, and visual search behavior of readers interpreting screening mammograms. Materials and Methods In this retrospective multireader paired study conducted between September 2024 and February 2025, 10 National Health Service Breast Screening Programme mammography readers evaluated a test set of two-view mammography screening examinations. The test set included true-positive (TP), false-negative (FN), false-positive (FP), and true-negative (TN) AI suggestions, verified by 3 years of follow-up or histopathologic analysis. In round 1, readers interpreted cases without AI. In round 2, conducted 6 weeks later, a commercially available AI tool was used as decision support, displaying prompts with a region score of 10 or higher (scale, 0-100). Eye-tracking cameras recorded readers' fixations-maintained gaze-over specific image areas. Wilcoxon signed rank tests were used for paired comparisons between rounds, and Kruskal-Wallis tests compared cases with different AI outcomes. Results The test set ( = 60) included cases with 26 TP, 14 FN, 14 FP, and six TN AI suggestions. Median reader sensitivity was lower for cases with FN AI suggestions when reading cases with AI (39%) compared with unassisted reading (71%; = .002). Reader specificity was higher for cases with FP AI suggestions (39% vs 21%; = .004). A greater number of visible (TP and FP) AI prompts led to longer median read times, from 25 seconds (zero prompts) to 34 seconds (four or more prompts) ( = .001). Readers fixated less when reviewing cancer cases that AI failed to detect (FN suggestions) compared with unassisted reading (0.44 vs 0.47 fixations per second; = .03). Shorter fixation durations were observed when readers interpreted cases with FP AI suggestions compared with unassisted reading (0.54 vs 0.56 second; = .001). Conclusion Incorrect AI suggestions influenced both reader accuracy and visual search behaviors during mammography interpretation. The greatest negative impact was observed with FN AI suggestions; therefore, AI thresholds should be calibrated accordingly. © RSNA, 2026 See also the editorial by Clauser in this issue. See also the editorial by Abbasi and Giess in this issue.
Adnan G Taib, George J W Partridge, Peter Phillips, Charles Maxwell-Armstrong, Xin Chen, Solveig S H Hofvind, et al. Automation Bias in Action: Eye Tracking of Humans Reading Screening Mammograms with and without AI Prompts.. Radiology. 2026; doi:10.1148/radiol.252590.
Adnan G Taib, George J W Partridge, Peter Phillips, Charles Maxwell-Armstrong, Xin Chen, Solveig S H Hofvind, et al (2026). Automation Bias in Action: Eye Tracking of Humans Reading Screening Mammograms with and without AI Prompts.. Radiology. https://doi.org/10.1148/radiol.252590
Adnan G Taib, George J W Partridge, Peter Phillips, Charles Maxwell-Armstrong, Xin Chen, Solveig S H Hofvind, et al. Automation Bias in Action: Eye Tracking of Humans Reading Screening Mammograms with and without AI Prompts.[J]. Radiology, 2026 doi:10.1148/radiol.252590.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出