含有生物活性颗粒的可流动复合树脂真的具有生物相容性吗?
Are flowable composite resins containing bioactive particles truly biocompatible?
Are flowable composite resins containing bioactive particles truly biocompatible?
分别采用体外和体内模型评估含生物活性颗粒的流动复合树脂的转化程度和生物相容性。测试的流动复合树脂为Beautifil Flow Plus F00(F00)、Beautifil Flow Plus F03(F03)和Filtek Supreme(FS)。转化程度(DC)测试中,每组制备7个样本并使用拉曼光谱分析。生物相容性(BC)测试中,每组7个样本植入21只雌性Wistar大鼠背部皮下组织,按实验周期7天、14天和28天分为三组。安乐死后,手术切除背部组织,福尔马林溶液固定并进行组织学分析。切片采用盲法评估,在400倍放大下随机选取十个显微视野。DC和BC的统计分析采用Kruskal-Wallis检验,随后DC采用Tukey事后检验,BC采用Dunn检验。在BC方面,F00和F03较FS引起的炎症和肉芽组织形成更少,并促进更多纤维化(p < 0.05)。在DC方面,各组间未观察到统计学显著差异(p > 0.05)。流动生物活性复合树脂是牙科实践中颇具前景的替代材料,因其引起的组织炎症轻微且转化率高。
To evaluate the degree of conversion and biocompatibility of flowable composite resins containing bioactive particles using in vitro and in vivo models, respectively. The flowable composite resins Beautifil Flow Plus F00 (F00), Beautifil Flow Plus F03 (F03), and Filtek Supreme (FS) were tested. For the degree of conversion (DC) test, seven specimens were prepared for each group and analyzed using Raman spectroscopy. For biocompatibility (BC), seven specimens from each group were implanted into the dorsal subcutaneous tissue of 21 female Wistar rats, which were divided into three groups according to the experimental periods of 7, 14, and 28 days. After euthanasia, the dorsal tissues were surgically excised, fixed in formalin solution, and processed for histological analysis. The slides were evaluated blindly, and ten microscopic fields were randomly selected at 400× magnification. Statistical analysis for DC and BC was performed using the Kruskal-Wallis test, followed by Tukey's post hoc test for DC and Dunn's test for BC. For BC, F00 and F03 induced less inflammation and granulation tissue formation and promoted greater fibrosis than FS (p < 0.05). For DC, no statistically significant difference was observed among the groups (p > 0.05). Flowable bioactive composite resins represent promising alternatives for dental practice, as they induce minimal tissue inflammation and exhibit high conversion rates.
Lara Rabelo Aragão, Julia Gonçalves Montenegro, Clarice Lioba de Araújo, José Vitor Mota Lemos, Dayrine Silveira de Paula, Sergio Lima Santiago, et al. Are flowable composite resins containing bioactive particles truly biocompatible?. Journal of clinical and experimental dentistry. 2026; doi:10.4317/jced.63914.
Lara Rabelo Aragão, Julia Gonçalves Montenegro, Clarice Lioba de Araújo, José Vitor Mota Lemos, Dayrine Silveira de Paula, Sergio Lima Santiago, et al (2026). Are flowable composite resins containing bioactive particles truly biocompatible?. Journal of clinical and experimental dentistry. https://doi.org/10.4317/jced.63914
Lara Rabelo Aragão, Julia Gonçalves Montenegro, Clarice Lioba de Araújo, José Vitor Mota Lemos, Dayrine Silveira de Paula, Sergio Lima Santiago, et al. Are flowable composite resins containing bioactive particles truly biocompatible?[J]. Journal of clinical and experimental dentistry, 2026 doi:10.4317/jced.63914.