区分胶质瘤复发和放射性坏死:正电子发射断层扫描和磁共振成像及其诊断准确性的叙述性综述

Differentiating glioma recurrence from radiation necrosis: a narrative review of positron emission tomography and magnetic resonance imaging and their diagnostic accuracies.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

胶质瘤复发与放射性坏死的鉴别仍是神经肿瘤学中的关键诊断难题,因为两者在影像学特征上存在重叠。正电子发射断层扫描(PET)和磁共振成像(MRI)可提供互补的代谢与结构信息,可能提高诊断准确性。本叙述性综述评估了PET、先进MRI技术及其联合应用在区分肿瘤复发与治疗后效应方面的表现。对PubMed、Medline和Embase数据库进行了全面检索,以识别2020年4月之后发表的研究。纳入标准为:使用PET和MRI对组织学确诊的胶质瘤进行研究,并报告敏感性、特异性或准确性。八项队列研究符合纳入标准,检查了PET示踪剂(18F-FDG、18F-FET、11C-MET、18F-DOPA)和先进MRI技术[扩散峰度成像(DKI)、动态磁敏感对比(DSC)灌注、磁共振波谱(MRS)]。除一项研究外,PET与MRI的联合应用在诊断准确性上均优于单一模态。18F-FET PET表现出较高的诊断准确性,敏感性高达95%,且在高级别胶质瘤中与MRI联合时未显示诊断改善,但其可及性仍然有限。单独MRI的敏感性(33-77%)和特异性(50-100%)因所用技术和示踪剂而异。DKI在提高敏感性方面显示出前景(72-100%)。方案和患者队列的异质性限制了研究之间的直接比较。PET与MRI的联合为区分胶质瘤复发与放射性坏死提供了更优的诊断方法,其中18F-DOPA PET与先进MRI序列的组合 emerged as 最有效的配对。需要采用标准化方案的多中心研究来验证这些发现,并解决示踪剂可及性和方案变异性相关挑战。这些进展有望优化神经肿瘤学中的患者管理。

Abstract

Differentiating glioma recurrence from radiation necrosis remains a critical diagnostic challenge in neuro-oncology due to overlapping imaging features. Positron emission tomography (PET) and magnetic resonance imaging (MRI) offer complementary metabolic and structural information that may enhance diagnostic accuracy. This narrative review evaluates the performance of PET, advanced MRI techniques, and their integration in distinguishing tumour recurrence from post-treatment effects. A comprehensive search of PubMed, Medline, and Embase databases was conducted to identify studies published after April 2020. Inclusion criteria comprised studies on histologically diagnosed gliomas using PET and MRI, reporting sensitivity, specificity, or accuracy. Eight cohort studies met the inclusion criteria, examining PET tracers (18F-FDG, 18F-FET, 11C-MET, 18F-DOPA) and advanced MRI techniques [diffusion kurtosis imaging (DKI), dynamic susceptibility contrast (DSC) perfusion, magnetic resonance spectroscopy (MRS)]. The integration of PET and MRI outperformed standalone modalities in diagnostic accuracy in all but one study. 18F-FET PET demonstrated high diagnostic accuracy, with sensitivity up to 95% and no diagnostic improvement when combined with MRI in high-grade glioma, though its availability remains limited. MRI alone had variable sensitivity (33-77%) and specificity (50-100%), depending on the technique and tracer used. DKI showed promise in enhancing sensitivity (72-100%). Heterogeneity in protocols and patient cohorts limited direct comparisons across studies. The combination of PET and MRI provides a superior diagnostic approach for differentiating glioma recurrence from radiation necrosis, with 18F-DOPA PET and advanced MRI sequences emerging as the most effective pairing. Further multicenter studies with standardized protocols are required to validate these findings and address challenges related to tracer accessibility and protocol variability. These advancements have the potential to optimize patient management in neuro-oncology.

如何引用

AMA

David Leen, Monica Wong, Eddie Lau, Sweet Ping Ng. Differentiating glioma recurrence from radiation necrosis: a narrative review of positron emission tomography and magnetic resonance imaging and their diagnostic accuracies.. Chinese clinical oncology. 2026; doi:10.21037/cco-24-133.

APA

David Leen, Monica Wong, Eddie Lau, Sweet Ping Ng (2026). Differentiating glioma recurrence from radiation necrosis: a narrative review of positron emission tomography and magnetic resonance imaging and their diagnostic accuracies.. Chinese clinical oncology. https://doi.org/10.21037/cco-24-133

GB/T 7714

David Leen, Monica Wong, Eddie Lau, Sweet Ping Ng. Differentiating glioma recurrence from radiation necrosis: a narrative review of positron emission tomography and magnetic resonance imaging and their diagnostic accuracies.[J]. Chinese clinical oncology, 2026 doi:10.21037/cco-24-133.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Chinese clinical oncology 的其他文献