定量双能CT衍生的水肿增强CT降低了骶骨脆性骨折诊断中与经验相关的变异性
Edema-Enhanced CT Derived from Quantitative Dual-Energy CT Reduces Experience-Related Variability in Sacral Fragility Fracture Diagnosis.
Edema-Enhanced CT Derived from Quantitative Dual-Energy CT Reduces Experience-Related Variability in Sacral Fragility Fracture Diagnosis.
骶骨骨折诊断困难。在双能计算机断层扫描(DECT)水/钙图像中,骨折部位的水肿表现为局部水等效密度增高。本研究开发了一种基于DECT的水肿增强CT(EECT)技术,并评估其对骶骨骨折的诊断性能。50例疑似骶骨骨折的日本患者(平均年龄82.4岁;41例女性)接受了单能CT(SECT)、DECT和磁共振成像(MRI)检查。在矢状位DECT上,将S1椎体中线的水等效密度定义为标准值(SV);每位患者16个感兴趣区中,计算相对标准值(RSV)即相对于SV的比值,并根据MRI表现进行分类。采用受试者工作特征曲线分析确定骨折检测的最佳RSV截断值,EECT图像突出显示超过该阈值的区域。随后由经验不足3年(A组)或超过10年(B组)的骨科外科医生使用SECT(S组)、DECT(D组)和EECT(E组)对30例患者进行两次独立评估(间隔>3个月),以评价骨折的存在及定位。采用Cochran Q检验、McNemar检验和Fisher精确检验比较各组间的敏感性、特异性、观察者间和观察者内信度以及诊断准确性。最佳RSV截断值为1.000。对于骨折检测和定位,EECT均显示出最高的敏感性、特异性和诊断准确性,尤其在骨折部位识别方面。EECT的观察者间和观察者内信度也最高,且使用SECT时观察到的经验不足与经验丰富观察者之间的性能差距在使用EECT时未观察到。EECT在骶骨骨折检测和定位方面表现出优于DECT和SECT的性能,无论观察者经验如何均提供高准确性和可靠性,可能对骶骨骨折有用。诊断证据级别IV。有关证据级别的完整描述,请参阅作者须知。
Sacral fractures are difficult to diagnose. In dual-energy computed tomography (DECT) water/Ca images, edema at fracture sites appears as locally increased water-equivalent density. This study developed an edema-enhanced CT (EECT) technique based on DECT and evaluated its diagnostic performance for sacral fractures. Fifty Japanese patients with suspected sacral fractures (mean age, 82.4 years; 41 women) underwent single-energy CT (SECT), DECT, and magnetic resonance imaging (MRI). On sagittal DECT, the water-equivalent density at the S1 vertebral midline was defined as the standard value (SV); in 16 regions of interest per patient, the relative standard value (RSV) was calculated as the ratio relative to the SV and classified according to MRI findings. Receiver operating characteristic curve analysis determined the optimal RSV cutoff for fracture detection, and EECT images highlighted regions exceeding this threshold. Thirty patients were then independently assessed twice (>3-month interval) by orthopaedic surgeons with <3 years (group A) or >10 years (group B) of experience using SECT (S group), DECT (D group), and EECT (E group) to evaluate fracture presence and localization. Sensitivity, specificity, inter- and intraobserver reliability, and diagnostic accuracy were compared among groups using Cochran Q, McNemar, and Fisher exact tests. The optimal RSV cutoff was 1.000. For both fracture detection and localization, EECT showed the highest sensitivity, specificity, and diagnostic accuracy, particularly for fracture site identification. Inter- and intraobserver reliability were also the highest with EECT, and the performance gap between less experienced and experienced observers seen with SECT was not observed when using EECT. EECT showed better performance than DECT and SECT in sacral fracture detection and localization, providing high accuracy and reliability regardless of observer experience, and it may be useful for sacral fractures. Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Takahiro Oda, Shimpei Kitada, Hitoshi Hirase, Kenjiro Iwasa, Takahiro Niikura. Edema-Enhanced CT Derived from Quantitative Dual-Energy CT Reduces Experience-Related Variability in Sacral Fragility Fracture Diagnosis.. The Journal of bone and joint surgery. American volume. 2026; doi:10.2106/JBJS.26.00200.
Takahiro Oda, Shimpei Kitada, Hitoshi Hirase, Kenjiro Iwasa, Takahiro Niikura (2026). Edema-Enhanced CT Derived from Quantitative Dual-Energy CT Reduces Experience-Related Variability in Sacral Fragility Fracture Diagnosis.. The Journal of bone and joint surgery. American volume. https://doi.org/10.2106/JBJS.26.00200
Takahiro Oda, Shimpei Kitada, Hitoshi Hirase, Kenjiro Iwasa, Takahiro Niikura. Edema-Enhanced CT Derived from Quantitative Dual-Energy CT Reduces Experience-Related Variability in Sacral Fragility Fracture Diagnosis.[J]. The Journal of bone and joint surgery. American volume, 2026 doi:10.2106/JBJS.26.00200.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出